Supplier: Honeywell International, Inc.
Description: SECOND (POWER OPEN)/10 SECOND (SPRING RETURN) MOTOR/ACTUATOR MOUNTING TYPE SIDE/TOP SERIES ARD MODEL
-
Supplier: ProMation Engineering, Inc.
Description: PDO Series 2300 in lbs / 260 Nm - w/ Manual Override The ProMation Engineering line of quarter-turn spring return industrial actuators are robust fail-safe actuators for industry. They are appropriately used on dampers and air handling louvers. Available in torque ranges to suit
- Actuator Torque: 2,300 In-lbs
- DC Voltage: 24 volts
- AC Voltage: 24 to 230 volts
- Operating Temperature: -22 to 150 F
-
Supplier: ProMation Engineering, Inc.
Description: P4 Series 3500 in lbs / 400 Nm - On/Off/Jog/Proportional The ProMation Engineering line of quarter-turn industrial actuators are our flagship products with regard to reliability, application flexibility, and optional configurations. They have been used primarily on butterfly and ball valves,
- Actuator Torque: 3,500 In-lbs
- DC Voltage: 12 to 24 volts
- AC Voltage: 12 to 480 volts
- Operating Temperature: -22 to 150 F
-
-
Supplier: NuAire, Inc.
Description: Motorized Control The automatic butterfly valve features the use of Belimo Actuators. Several varieties of Belimo® Actuators are available depending on the application. Consult NuAire engineering for assistance in choosing the correct butterfly valve and actuator. - 14 gauge,
-
Supplier: Enervex, Inc.
Description: The EXHAUSTO ADF Automatic Damper is a single blade, two position damper powered by an actuator, with flanged connections. The ADF is available in standard stack diameters ranging from 6 to 36 inches. The actuator will be interlocked with a boiler or gas fireplace to open the damper
-
Supplier: Johnson Controls, Inc.
Description: round ducts. Round dampers are available with or without a factory-installed actuator. FEATURES AND BENEFITS Formed shroud. Inserts easily into round ductwork Available factory-installed actuator. Reduces installation time. One-piece construction. Increases rigidity and strength.
-
Supplier: Johnson Controls, Inc.
Description: round ducts. Round dampers are available with or without a factory-installed actuator. FEATURES AND BENEFITS Formed shroud inserts easily into round ductwork Available factory-installed actuator reduces installation time. One-piece construction increases rigidity and strength.
-
Supplier: Johnson Controls, Inc.
Description: as 5 Working Days after Order Entry - provides faster response for projects, at a cost premium. Modulating actuators allow for use as volume control dampers. Available factory-installed blade position switch kit with direct coupling provides feedback of blade position instead of
-
Supplier: Fläkt Woods Group SA
Description: Fire and smoke damper ETPR-E-1 is used as a closing device for preventing the spread of fire and smoke in ventilation ducts between fire compartments. Fire dampers are equipped with fusible link and spring mechanism for closing or with electrical actuator.
-
Supplier: Honeywell International, Inc.
Description: HEATING/COOLING/VENTILATION/DIRECT COUPLED ACTUATOR SERIES D690 MODEL
-
Supplier: Fläkt Woods Group SA
Description: ETPS-E is a rectangular fire damper equipped with an actuator and CE marked based on product standard EN 15650:2010. The damper fulfils the requirements of fire class E 60 / E 90 / E 120. The damper is installed in the ventilation duct between fire compartments to stop the spread of flue
-
Supplier: Rotolok Valves, Inc.
Description: The fabricated range of Rotolok Butterfly Dampers are used extensively in the air and dust handling industries generally in fan systems. They are normally operated remotely by air cylinders, electric or pneumatic actuators, although manual versions through the customary hand lever, handwheel
-
Supplier: Texel-Seikow USA, Inc.
Description: TEXEL-SEIKOW NDP series dampers offer excellent corrosion resistance while handling large volume air flows. The dampers are made of FRP (Fiberglass Reinforced Plastic). Customers can choose the NDP dampers with either Worm Gear operated with hand wheel or pneumatic type with actuator.
-
Supplier: Enervex, Inc.
Description: A chimney top mounted automated damper for use with gas fireplaces and model RS Chimney Fan. The MFD prevents excess heat from escaping through the chimney when the fireplace is not in use. The ultra low profile MFD comes equipped with an actuator that is interlocked to the ADC 100 so it only
-
Supplier: Johnson Controls, Inc.
Description: The FS-1620 Fire/Class II Smoke Damper is designed to prevent the spread of smoke and its 1-1/2 hour fire rating is for use within a dynamic HVAC system during life safety situations. FEATURES AND BENEFITS 1-1/2 hour fire rating 250 or 350°F rated actuators Three-year warranty on materials
-
Supplier: Armstrong International
Description: Special dampers, controlled by a pneumatic actuator connected to a temperature sensor, adjust the leaving-air temperature by channeling the appropriate volume of entering air across the heating coils and allowing the remaining air to pass through by-pass channels. As entering air temperature
- Maximum Operating Temperature: 400 F
- Maximum Operating (Sheath) Temperature: 400 F
- Heater Type: Air Heater, Inline Heater
- Fuel / Energy Source: Hot Water / Steam
-
Supplier: ASTM International
Description: toward the exterior. 1.2.4 Type D-A window assembly which incorporates one or more fixed panes (lites) or stationary sash that are designed not to open. 1.2.5 Type E-A window assembly which incorporates a series of overlapping horizontal louvers that are pivoted simultaneously by a common
Find Suppliers by Category Top
Featured Products Top
-
) and motor controllers. Actuating dampers, louvers, and valve positioners in HVAC and building automation systems. Controlling heaters, coolers, and other thermal regulation elements. Driving chart recorders, panel meters, and other (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
(VFDs) and motor controllers. Actuating dampers, louvers, and valve positioners in HVAC and building automation systems. Controlling heaters, coolers, and other thermal regulation elements via their analog inputs. Driving analog panel (read more)
Browse Data Output Modules Datasheets for Sichuan Odot Automation System Co., Ltd.
More Information Top
-
Energy management through building automation
Standardization terminates on the base a very extensive the KNX-/-EIB devices like, e.g., room thermostat blind actuator assess strong field bus plane that i.e. over extensive applications that only require a flat automation layer.
-
Heat Transfer and Thermal Control > Transient Response of Thermal Louvers with Bimetallic Actuators
the louver actuator response could lead to a temperature in- crease above qualification limits.
-
Design of a continuous duty cryopump
5.1.3 Louver Actuators .
Indicates content that may require registration and/or purchase.