Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Mile-X Equipment, Inc.
Description: batteries.Simple infield memory calibration - no calculations or disassembling of the meter are required.Flange coupled and sealed to the control valve. No adapters or fittings to leak. (moisture proof)Large (quarts) batch display, resetable after each use. Permanent, non-resetable
-
Supplier: Mile-X Equipment, Inc.
Description: Electronic Lube Meter For mineral and synthetic lubricants up to 140 SAE1/2" inlet, 0.25 to 8 gallon/minute Digital Oil Meter Accuracy: plus or minus 0.5% Patented electronic circuit board for today's high quality demands. Precision engineered oval gears with 200 pulses per unit of
-
Supplier: Caterpillar Oil & Gas
Description: Communication Module Customer Interface Box Remote panel display Remote cylinder temperature display Exhaust temperature thermocouples Discrete I/O module Intake manifold temperature sensors Oil temperature sensor LUBE SYSTEM Duplex oil filter Bypass
- Volt-Ampere: 1,475,000 to 2,281,000 VA
- Applications: Industrial
- Portability: Permanent
-
-
Supplier: Caterpillar Oil & Gas
Description: panel, LH Engine oil pressure gauge Fuel pressure gauge Water temperature gauge Tachometer Lube System Crankcase breather, top mounted Oil cooler Oil filler in valve cover and dipstick, both RH Lube oil filter Rear sump oil pan Mounting
- Horse Power: 638 to 739 HP
- Displacement: 27.038633920324635 liters
- Length: 78 inch
- Width: 51.2 inch
-
Supplier: Caterpillar Oil & Gas
Description: Instrumentation Remote-mounted Advisor control panel Interconnect harness Lube System Top-mounted crankcase breathers Oil cooler Oil filter and oil sampling valve Drain valve Turbo oil accumulator API B16.3 approved gas/air-driven
- Horse Power: 1,380 HP
- Displacement: 69.31722514119588 liters
- Fuel Type: CNG
- Application: Industrial
-
Supplier: Caterpillar Oil & Gas
Description: for Unattended Operation Pressure switches, mounted on engine, for: – Lube oil pressure at full load below danger level – Low lube oil pressure – Lube oil pressure below danger level – Lube oil pressure prelubrication failed – Low fresh water
- Volt-Ampere: 2,400,000 VA
- Applications: Industrial
- Portability: Permanent
-
Supplier: Aerzen USA Corp.
Description: operation Ideal for continuous operation without the problem of overheating Experts in vacuum: AERZEN blowers with pre-inlet cooling For pre-inlet cooling the housing is equipped with an additional third socket on the suction side. The lube oil supply is effected by splash oil
- Air Flow Rate: 147.15 to 35,904.6 SCFM
- Static Pressure: 4.014662164032441 to 120.40855869571234 in H2O
- Product Form: Bare (No Motor, Controls)
- Environment: Clean Air / Gas, Corrosive Gases
-
Supplier: Westerbeke Corporation
Description: support. Standard Features Simple, "one-touch" start/stop control panel with running hour meter and LED lights Electronic fuel injection Electronic governing Safety shut-downs-overspeed, low oil pressure, high exhaust temperature Fresh water cooling and coolant recovery tank
- Wattage: 4,200 watts
- Fuel Type: Gasoline
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: support. Standard Features Simple, "one-touch" start/stop control panel with running hour meter and LED lights Electronic fuel injection Electronic governing Safety shut-downs-overspeed, low oil pressure, high exhaust temperature Fresh water cooling and coolant recovery tank
- Wattage: 5,400 watts
- Fuel Type: Gasoline
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: support. Standard Features Simple, "one-touch" start/stop control panel with running hour meter and LED lights Electronic fuel injection Electronic governing Safety shut-downs-overspeed, low oil pressure, high exhaust temperature Fresh water cooling and coolant recovery tank
- Wattage: 6,500 watts
- Fuel Type: Gasoline
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: support. Standard Features Simple, "one-touch" start/stop control panel with running hour meter and LED lights Electronic fuel injection Electronic governing Safety shut-downs-overspeed, low oil pressure, high exhaust temperature Fresh water cooling and coolant recovery tank
- Wattage: 5,000 watts
- Fuel Type: Gasoline
- Applications: Industrial
Find Suppliers by Category Top
Featured Products Top
-
operation in demanding industrial environments. Engineered for high-pressure and wide-temperature applications, these valves support efficient automation performance across oil & gas, chemical processing, power generation, and pharmaceutical industries (read more)
Browse Control Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
HMT/HDT Pneumatic 3-Way Control Valves are designed for precise flow regulation in industrial process control systems. The HMT series is optimized for mixing applications, while the HDT series (read more)
Browse Control Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
THINKTANK Electric Globe Control Valves are designed for accurate process control in critical industrial applications. Combined with intelligent electric actuators, these valves deliver reliable regulation of flow, pressure, temperature, and other process variables while supporting automated (read more)
Browse Globe Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
High-Temperature Safety Valves for Industrial Pressure Protection Industrial steam systems and high-pressure pipelines require reliable safety valves capable of operating (read more)
Browse Industrial Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
Process industries often require control valves capable of maintaining stable flow performance under high pressure, high differential pressure, and challenging temperature conditions. The HCB Series Pressure-Balanced Cage Control Valve is engineered for these demanding applications, providing (read more)
Browse Control Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
Extreme-Condition Balanced Cage Control Valve – Precision, Stability, and Durability The HCB DN50 300LB balanced cage control valve is engineered for high-pressure, high-temperature process applications, ensuring stable flow (read more)
Browse Control Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
In industrial fluid systems, valves must ensure accurate flow control, corrosion resistance, and long-term stability. 3-way valve configurations enable flexible process control in complex systems (read more)
Browse Control Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
Customer Metroval specified Rotork intelligent IQ3 multi-turn electric actuators, as well as CP and GP pneumatic actuators, to control plug and butterfly valves on an FPSO, which will operate in the LIBRA oil fields in the Atlantic Ocean’s Santos Basin. The FPSO operating at the site is (read more)
Browse Electric Valve Actuators Datasheets for Rotork plc -
mixing with oil on the cylinder liner(s). Excessive soot causes abnormal valve and injector train wear, can overload the emissions control systems leading to air quality fines. So what tests should be included for Engine oil monitoring ? Any testing for engines needs to incorporate tests to (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
ThermOmegaTech® specializes in temperature based control solutions. Our thermostatic thermal bypass valves automatically and precisely divert inlet flow to a heat exchanger or bypass it directly to a reservoir based solely on fluid temperature. These valves ensure accurate control of fluid (read more)
Browse Industrial Valves Datasheets for ThermOmegaTech®
Conduct Research Top
-
The Importance of Temperature Control in Hydraulic and Lube Oil Systems
Proper temperature control is necessary for maintaining appropriate fluid viscosity levels in hydraulic and lube oil systems - Implementing thermostatic temperature control valves will ensure optimal system performance, increase machine uptime, and reduce service and repair costs due to operation
More Information Top
-
http://dspace.mit.edu/bitstream/handle/1721.1/33577/63518079-MIT.pdf?sequence=2
As the shaft generates more friction, the propulsion lube oil temperature increases, and the pneumatically controlled Lube Oil Service System temperature regulating valve repositions to allow more lube oil to be directed to the coolers.
-
Air Cycle Cooling System for HPOF Cables-Waltz Mill Tests
Bypass valve to control inlet air temperature Lube Oil System 18.
-
DOE Backup Power Working Group Best Practices Handbook for Maintenance and Operation of Engine Generators, Volume II
On some large diesels, regulating valves are used to control the lube oil temperature .
-
Compressors: How to Achieve High Reliability & Availability > Compressor Failure Analysis Overview
Decrease cooling water flow through lube oil cooler, check water inlet temperature , and confirm water control valve is properly sized for adequate flow control.
-
EXPERIMENTAL GAS COOLED REACTOR. FINAL HAZARDS SUMMARY REPORT. VOLUME I. DESCRIPTION AND HAZARDS EVALUATION (Book 1 and Book 2)
Lube oil temperature is regulated by bypassing lube oil around the lube oil cooler through an automatically operated, three-way temperature control valve .
Indicates content that may require registration and/or purchase.