-
Supplier: Panel Components & Systems, Inc.
Description: condition. When the temperature exceeds the predetermined temperature, the resistance of the thermistor rapidly increases, this increase in temperature is detected by M200-TTA/TTM and the relay is de-energised. The M200-TTM is manually reset. Once the relay has de- energised it will
-
Supplier: Panel Components & Systems, Inc.
Description: condition. When the temperature exceeds the predetermined temperature, the resistance of the thermistor rapidly increases, this increase in temperature is detected by M200-TTA/TTM and the relay is de-energised. The M200-TTM is manually reset. Once the relay has de- energised it will
-
Supplier: Newark, An Avnet Company
Description: PROTECTOR RELAY MILLIVOLT TRIP HIGH TRIP 40 TO 120% INPUT 100 MILLIVOLTS DC RELA ROHS COMPLIANT: NA
-
-
Supplier: Acromag, Inc.
Description: 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC) 10 to 36V DC, 24V AC power Modbus-RTU high-speed RS-485 This signal conditioner is a four-channel analog input module with four discrete
- Analog Input Channels: 4 #
- Operating Temperature: -13 to 158 F
- Temperature Measurement Range: -436 to 3,308 F
- Resolution: 16 bits
-
Supplier: Newark, An Avnet Company
Description: MILLIVOLT HIGH TRIP 40 TO 120% INPUT 50 MVDC, RELAY OUTPUT WITH VOLT FREE CONTACTS 24V DC OPTION DELAY 0/10 SECA (STD)
-
Supplier: Panel Components & Systems, Inc.
Description: current does not exceed 300 amps then the MVO trip would be set at 75 % (56.25mv). If the current goes above 300 Amps the relay would energise. As is common with all the M200 relays, on over units the relay energises when the input signal exceeds the trip point and on under
-
Supplier: Panel Components & Systems, Inc.
Description: current does not exceed 300 amps then the MVO trip would be set at 75 % (56.25mv). If the current goes above 300 Amps the relay would energise. As is common with all the M200 relays, on over units the relay energises when the input signal exceeds the trip point and on under
-
Supplier: SensorsONE, Ltd.
Description: The readings of the 40B 48 millivolt input digital indicator are settable via the IP 65 face panel controls to adjust the relay trip points, decimal place, display update rate, resolution, engineering units and input linearisation. Two buttons on the face panel can be configured for a
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, TEMPERATURE CONTROLLER, 1/16 DIN, AUTOTUNE, 3.5 DIGIT LED READOUT, CELSIUS / FAHRENHEIT, THERMOCOUPLE 2-WIRE RTD / LINEAR MILLIVOLT INPUT, 5A MECH RELAY OUTPUT 1, 3A MECH RELAY OUTPUT 2, 115 VAC SUPPLY. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: ACCES I/O Products, Inc.
Description: Features Designed for long-term standalone data logging (months or more) "Mass Storage Device" interface for configuration and downloading data 2 differential 16-bit analog inputs Form C electromechanical relay switches up to 1A Flexible on-device monitoring and alarm functionality External
- Analog Input Channels: 2 #
- Resolution: 16 bits
- Operating Temperature: -40 to 185 F
- Features: Application Software Included, DC Current Input, DC Voltage Input
-
Supplier: Honeywell Test & Measurement
Description: The Model UV amplifier supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to a ±10 Vdc signal. The Universal In-line features two selectable exciation voltages, programmable gain settings, a wide adjustment range on the
- Operating Temperature: 5 to 159.8 F
-
Supplier: Honeywell Test & Measurement
Description: The Model UBP bi-polar amplifier supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to a ±5 Vdc signal. The Universal In-line features two selectable excitation voltages, programmable gain settings, a wide adjustment
- Operating Temperature: 5 to 159.8 F
-
Supplier: Honeywell Test & Measurement
Description: The Model UV-10 amplifier supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to a ±10 Vdc signal. The Universal In-line features two selectable exciation voltages, programmable gain settings, a wide adjustment range on
- Operating Temperature: 5 to 159.8 F
-
Supplier: Honeywell Test & Measurement
Description: The Model U3W amplifier supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the transducer to a 4 mA to 20 mA three-wire current output signal. The Universal In-line features two selectable excitation voltages, programmable gain
- Operating Temperature: 5 to 159.8 F
-
Supplier: Acromag, Inc.
Description: Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), 0 to 500 ohms input 0 to 20mA DC, 0 to 10V DC output Mechanical relay (25V @ 5A) alarm 10-36V DC power Software configured Performs linearization, square root extraction, and optional limit alarm functions
- Sensed Temperature: -382 to 1,562 F
- Operating Temperature: -13 to 158 F
- Reference Resistance: 10 Ohms, 100 Ohms, 120 Ohms, 500 Ohms
- Other Input: Analog Current
-
Supplier: Acromag, Inc.
Description: Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), 0 to 500 ohms input 0 to 20mA DC, 0 to 10V DC output Mechanical relay (25V @ 5A) alarm 10-36V DC power Software configured Performs linearization, square root extraction, and optional limit alarm functions
- Analog Input Channels: 1 #
- Accuracy: 0.075 % FS
- Operating Temperature: -13 to 158 F
- Temperature Measurement Range: -436 to 3,308 F
-
Supplier: ValueTronics International, Inc.
Description: 57-440 Hz, 100 Watts nominal Output 0-60 Volts DC, continuously adjustable with the following minimum output: 0-7V, 0-5A, 0-15V, 0-3A 0-25V, 0-2A 0-50V, 0-1A 0-60V, 0-0.5A Line regulation: 0.01% + 1 millivolt for line variations from 105-125 volts Load regulation: 0.01% + 1 millivolt
- DC Output Power: 60.00000000000001 watts
- Type: DC Power Supply
-
Supplier: Acromag, Inc.
Description: Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), 0 to 500 ohms input 0 to 20mA DC, 0 to 10V DC output Mechanical relay (25V @ 5A) alarm 10-36V DC power Software configured Performs linearization, square root extraction, and optional limit alarm functions
- Sensed Temperature: -382 to 1,562 F
- Operating Temperature: -13 to 158 F
- Reference Resistance: 10 Ohms, 100 Ohms, 120 Ohms, 500 Ohms
- Other Input: Analog Current
-
Supplier: Russells Technical Products
Description: between degrees Celsius or Fahrenheit Analog inputs Selectable inputs: T/C, RTD, Voltage, Current, Millivolt (8 channels included) expandable to 64 Controls Completely configurable 4 channels of control plus true PI control for product control Programmable restart modes after power failure
- Number of Inputs: 8 inputs
- Number of Control Outputs: 4 outputs
- Control Signal: Analog Voltage, Current Loop, Pulse / Frequency, Serial / Digital, Switch / Relay Output
- Interface: Computer Programmable, Digital Front Panel
-
Supplier: Scientific Test, Inc.
Description: Scientific Test semiconductor tester is highly reliable, extemely fast, very easy to operate. From picoamps to over 1000 amperes and from millivolts to 2000 volts..... numerous semiconductor devices can be tested with our 5000 Series automatic semiconductor tester. With its on-board
-
Supplier: OMEGA Engineering, Inc.
Description: accepts 100 to 250 Vac and 120 to 250 Vdc. A 24 Vac/24 Vdc power supply option is also available. Calibrations for most thermocouples and RTD's are available, as well as for millivolt linear, volt linear, and current linear inputs. Unlike the CN8200 1/16 DIN models, these controllers have
- Number of Control Outputs: 1 outputs
- Accuracy: 0.2 ±% FS
- Control Signal: Analog Voltage, Current Loop, Switch / Relay Output
- Interface: Computer Programmable, Digital Front Panel
-
Supplier: OMEGA Engineering, Inc.
Description: accepts 100 to 250 Vac and 120 to 250 Vdc. A 24 Vac/24 Vdc power supply option is also available. Calibrations for most thermocouples and RTD's are available, as well as for millivolt linear, volt linear, and current linear inputs. Unlike the CN8200 1/16 DIN models, these controllers have
- Number of Control Outputs: 2 outputs
- Control Signal: Analog Voltage, Pulse / Frequency, Serial / Digital, Switch / Relay Output
- Type: Current Loop (Transmitter) Input, DC Voltage Input
- Form Factor: DIN Rail
-
Supplier: ValueTronics International, Inc.
Description: The 1381 and 1382 are companion instruments that generate truly random noise from a semiconductor source. Special precautions are taken to ensure a symmetrical, Gaussian amplitude distribution. Output level is adjustable from below 3 millivolts to 3 volts rms behind a 600-ohm source
- Generator Type: Noise, Signal
- Features: Noise Generator
Find Suppliers by Category Top
More Information Top
-
Controlled pH and oxidation–Reduction potential with a new glass tissue‐culture fermentor
Control panels for a battery of three 1-1. fermentors: A, pH indicator- controller; B, pH recorder; C, pH relays; D, pH asymmetry control; E, milli- volt indicator-controller ; F, millivolt recorder; G, millivolt relays ; H, milli- volt asymmetry control; I, &loo%…
-
Nano Devices and Circuit Techniques for Low-Energy Applications and Energy Harvesting
Zaghloul U, Piazza G (2014) Sub-1-volt piezoelectric nanoelectromechanical relays with millivolt switching capability.
-
Monitoring tablet dissolution with a sodium ion‐selective glass electrode
The electrode potential was measured with a pH meter3operated in the expanded millivolt position, with the signal relayed to a recorder'.
-
Carlo Gavazzi/Electromatic Controls | Temperature Controllers | Product Catalog Search Results | Galco Industrial Electronics
Power Supply: 100~240 VAC;12/24 VDC, Case Size: 1/16 DIN, Input Type: RTD;Thermocouple;millivolts AC; millivolts DC, Output Type: Electromechanical Relay , Number of Outputs: 2, Display Type: LED, Nominal Power Supply: 120 VAC;240 VAC;12 VAC;24 VAC;12 VDC;24 VDC, Thermocouple Class: B;E;J;K;L;N;R;S;T, Approvals: UL;CSA;CE .
-
Temperature Controllers | Product Catalog Search Results | Galco Industrial Electronics
Power Supply: 12 VAC;24 VAC;12 VDC;24 VDC;100~240 VAC, Case Size: 1/32 DIN, Input Type: RTD;Thermocouple; millivolts DC, Output Type: Electromechanical Relay ;Solid State Relay, Number of Outputs: 2, Display Type: LED, Nominal Power Supply: 120 VAC;240 VAC;12 VAC;24 VAC;12 VDC;24 VDC, Thermocouple Class: B;E;J;K;L;N;R;S;T, Approvals: UL; CSA .
-
Nanoscience
Ion channels lie at the interface between two areas of science: as physiologi- cal relays in biology and as picoampere/ millivolt conductors in physics.
Indicates content that may require registration and/or purchase.