Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Edmund Optics Inc.
Description: AD-080 offers high resolution, simultaneous imaging of the visible and near-infrared (NIR) spectrums through the use of two sensors optimized from 400 - 700nm and 750 - 900nm. Using two CCDs, the AD-081 features the unique ability to perform high dynamic range imaging; one CCD
- Maximum Frame Rate: 30 fps
- Sensitivity: 0.5 Lux
- Lens Mount: C-Mount
- Features: CCD
-
Supplier: Edmund Optics Inc.
Description: AD-080 offers high resolution, simultaneous imaging of the visible and near-infrared (NIR) spectrums through the use of two sensors optimized from 400 - 700nm and 750 - 900nm. Using two CCDs, the AD-081 features the unique ability to perform high dynamic range imaging; one CCD
- Maximum Frame Rate: 30 fps
- Sensitivity: 1.4 Lux
- Lens Mount: C-Mount
- Features: CCD
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Wavelength Range: 600 to 1,000 nm
- Spectral Resolution: 1 nm
- Stray Light: 0.1 %
-
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Wavelength Range: 600 to 800 nm
- Spectral Resolution: 1 nm
- Stray Light: 0.1 %
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Wavelength Range: 550 to 840 nm
- Spectral Resolution: 1 nm
- Stray Light: 0.1 %
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Wavelength Range: 785 to 1,150 nm
- Spectral Resolution: 1 nm
- Stray Light: 0.1 %
-
Supplier: Konica Minolta Sensing Americas, Inc.
Description: distribution and radiant intensity of 850 or 940 nm near-infrared (NIR or near-IR) emitters. The NIR Intensity Lens system utilizes Fourier optics to capture a full cone of data in a single measurement to ±70 degrees, giving you extremely fast, accurate results ideal for in-line
- Features: CCD, Other
- Monochrome / Color: Color
- Camera Function: Still
-
Supplier: Edmund Optics Inc.
Description: AD-080 offers high resolution, simultaneous imaging of the visible and near-infrared (NIR) spectrums through the use of two sensors optimized from 400 - 700nm and 750 - 900nm. Using two CCDs, the AD-081 features the unique ability to perform high dynamic range imaging; one CCD
- Sensitivity: 1.1 Lux
- Lens Mount: C-Mount
- Features: CCD
- Shutter Control: Electronic Shutter
-
Supplier: Edmund Optics Inc.
Description: AD-080 offers high resolution, simultaneous imaging of the visible and near-infrared (NIR) spectrums through the use of two sensors optimized from 400 - 700nm and 750 - 900nm. Using two CCDs, the AD-081 features the unique ability to perform high dynamic range imaging; one CCD
- Sensitivity: 0.34 Lux
- Lens Mount: C-Mount
- Features: CCD
- Shutter Control: Electronic Shutter
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-8000 is designed for 900-2600nm NIR, miniature optic fiber spectrometer. It employs 256/512 pixels cooled InGaAs Array, semiconductor cooling technology CCD, cooled down to -20ºC under constant operating temperature, resulting in low noise, 2 times SNR higher than competitors,
- Wavelength Range: 900 to 2,600 nm
- Spectral Resolution: 5 nm
- Operating Temperature: 32 to 122 F
- Detector Type: Charge Coupled Device (CCD)
-
Supplier: Vision Components GmbH
Description: Smart Cameras are amongst others the better choice for barcode or DMC decoding and object recognition. 2/3" CCD sensor resolution 1280 x 1024 Pixel frame rate 14 fps Near Infra Red wave lengths up to 1100 nm high-speed shutter: up to 5 µs low-speed shutter: up to 17,6 s adjustable integration
- Imaging Technology: Smart Camera
- Camera Function: Video
-
Supplier: StellarNet, Inc.
Description: CCD with options for 2048 or 3648 elements. Various models provide a choice of grating range and slit resolutions. New and improved electronics with a high speed 16-bit digitizer allows for fast data acquisition and a signal to noise of 1000:1! Up to 8 units can be daisy chained together
- Spectral / Wavelength Range: 500 to 1,150 nm
- Resolution: 0.8 nm
- Remote Interface: Application Software Included, Serial Interface
- Features: Computer Interface, Data Processing Functions, Data Storage / Data Logger, On-line Monitoring & Process Control, Portable, Solid State (CCD)
-
Supplier: StellarNet, Inc.
Description: The StellarNet GREEN-Wave low cost Spectrometers are fiber optic coupled instruments with a wide selection of models for measurements in 190-1150nm wavelength ranges. Each unit contains a USB interface with a snap shot memory to provide instantaneous spectral image from the highly sensitive
- Spectral / Wavelength Range: 500 to 1,150 nm
- Resolution: 0.8 nm
- Accuracy: 0.2 nm
- Remote Interface: Application Software Included, Serial Interface
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Wavelength Range: 350 to 1,100 nm
- Spectral Resolution: 4 nm
- Operating Temperature: 32 to 104 F
- Computer Interface Options: Application Software Included
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Wavelength Range: 350 to 1,100 nm
- Spectral Resolution: 2.6 nm
- Operating Temperature: 32 to 104 F
- Computer Interface Options: Application Software Included
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Wavelength Range: 350 to 1,100 nm
- Spectral Resolution: 2.6 nm
- Operating Temperature: 32 to 104 F
- Computer Interface Options: Application Software Included
-
Supplier: Security Camera Warehouse
Description: Sony SCD702NIR Product Key Features 1/3" Sony Super HAD Color CCD 480 TV Lines 0 Lux (23 pieces IR LED on), 66FT IR Distance 3.6mm Lens Vandal Proof IP66 Water Resistance Auto Tracking White Balance, BLC, AGC DC 12V Sony SCD702NIR Product Specifications Image Device: 1/3" Sony Super HAD
- Specialty Camera Type: Low Light
- Camera Function: Video
-
Supplier: Metrohm USA, Inc.
Description: 0.1% of current output range Measured potential resolution - 0.012 % of potential range Measured current resolution - 0.025 % of current range Spectrometer (SPM) Detector - Linear silicon CCD array SPM Pixels - 2048 SPM Pixel size - 14 µm x 200 µm SPM Pixel well depth - 62,500 electrons SPM
- DC Current Range: 0.04 amps
- DC Voltage Range: 4 volts
-
Supplier: Ophir-Spiricon Inc.
Description: Low cost, compact, high resolution CCD NIR camera
- Spectral Range: 0.19 to 0.98 microns
- Horizontal: 768 lines
- Vertical: 494 lines
- Maximum Dimension: 2 inch
-
Supplier: Allied Vision Technologies GmbH
Description: response for excellent image quality and sensitivity. The GB660 is available with optional vertical connector orientation. Models: GB660, 659x493, 120 fps, CCD, Mono GB660C, 659x493, 120 fps, CCD, Color GB660-V, 659x493, 120 fps, CCD, Mono, Vertical GB660C-V, 659x493, 120 fps,
- Horizontal Resolution: 659 lines
- Maximum Frame Rate: 120 fps
- Shutter Speed: 0.000009999999999996 to 60 seconds
- Width / Diameter: 2.0078751 inch
-
Supplier: Allied Vision Technologies GmbH
Description: Ultra-compact, inexpensive 0.4 Megapixel camera - interlaced, high sensitivity The Guppy F-044B/C is equipped with an ultra-sensitive interlaced CCD sensor - which makes the move from analog to digital cameras very easy. Additionally, with the Guppy F-044B/C NIR, a version with
- Horizontal Resolution: 752 lines
- Maximum Frame Rate: 25 fps
- Shutter Speed: 0.0000619999999999752 to 67.0000000000002 seconds
- Width / Diameter: 1.181103 inch
-
Supplier: Allied Vision Technologies GmbH
Description: Right-angle GigE Vision camera, Ex-view sensor, 120 fpsThe GS660 is a fast, VGA-resolution, high-performance machine vision camera with Gigabit Ethernet interface (GigE Vision„¢). The GS660 incorporates a Sony ExView HAD CCD sensor that has particularly high quantum efficiency and excellent
- Horizontal Resolution: 659 lines
- Maximum Frame Rate: 120 fps
- Shutter Speed: 0.000009999999999996 to 60 seconds
- Width / Diameter: 2.1653555 inch
-
Supplier: VAST STOCK CO., LIMITED
Description: Image Sensors PYTHON 2000 NIR
-
Supplier: Hamamatsu Photonics Europe
Description: Enhanced near infrared sensitivity, Constant element temperature control The S16011 series is a family of back-thinned FFT (full frame transfer)-CCD image sensors for photometric applications that offer improved sensitivity in the near infrared region at wavelengths longer than 800 nm. In
- Horizontal Pixels: 2,048
- Vertical Pixels: 64
- Pixel Size: 14 µm
- Spectral Response: 200 to 1,100 nm
-
Supplier: IDS (Imaging Development Systems) GmbH
Description: The GV-5240CP is a particularly powerful industrial camera with the e2v 1.31 MPix CMOS sensor. This is one of the most sensitive sensors in the IDS product portfolio and it is available in monochrome, colour (EV76C560ABT/EV76C560ACT), and as NIR version (EV76C661ABT). The sensor offers an
- Applications: Assembly Quality, Biotechnology or Medical, Production & Quality Control
- Image Source: Thermal or Infrared
-
Supplier: Qioptiq
Description: (350 - 880 nm), UV (220 - 400 nm), NIR (750 - 940 nm) Grating: 600 lines/mm (VIS), 1200 lines/mm (NIR), 1800 lines/mm (UV) Entrance Slit: 20 μm Spectral Resolution: VIS 0.5 nm, UV 0.2 nm, NIR 0.3 nm Dynamic Range / SNR: 2000 : 1 (full scale, texp = 1 s) Stray Light: < 0.05 %
- Wavelength Range: 220 to 940 nm
- Spectral Resolution: 0.2 nm
- Stray Light: 0.05 %
- Operating Temperature: 5 to 140 F
-
Supplier: Yankee Environmental Systems, Inc.
Description: pressure), a TSP-400 visible/NIR pyranometer (solar), and 2-D wind speed and direction (sonic or wind vane/anemometer). Optional sensors include TSI-880 Automated Total Sky Imagers, UVB-1 or UVA-1 UV pyranometers, TIR-550 IR radiometers, optical visibility and precipitation sensors, laser
-
Supplier: Yankee Environmental Systems, Inc.
Description: The state-of-the-art Rotating Shadowband Spectroradiometer (RSS) combines a high-performance 1024-pixel CCD spectrograph with an external rotating shadowband similar to that used in our MFR instrument family. It automatically provides instantaneous direct, diffuse, and total irradiance
-
Supplier: ASTM International
Description: having a broader range than others. Extending these methods to the near infrared (NIR) beyond 830 nm will be discussed briefly, where appropriate. These methods were designed for scanning fluorescence spectrometers with a single channel detector, but can also be used with a multichannel
Find Suppliers by Category Top
Featured Products Top
-
Hamamatsu Photonics has officially launched the WS Series Mini-Spectrometers, a cutting-edge solution designed to meet the diverse needs of UV to NIR spectroscopy applications. This innovative lineup features two distinct models: the C16449MA-01 and the C16449MA-02. The C16449MA-01 model boasts (read more)
Browse Uncategorized Products Datasheets for Hamamatsu Photonics Europe
Conduct Research Top
-
Using NIR for Inspection Applications
This week, Lumenera is at the SPIE Defense + Commercial Sensing (SPIE DCS) show demonstrating our Lt16059HM, a USB 3.0 industrial grade 16 MP CCD large format monochrome camera with Canon lens and a visible light blocking filter. Using an 850 nm NIR light ring we will be demonstrating how
-
A NIR-to-NIR Upconversion Luminescence System for Security Printing Applications
-to-NIR images are easily captured, however, using an inexpensive, modified point-and-shoot CCD camera, even at modest excitation power densities (1.5 W cm-2). It is demonstrated that the latent images can also be read through select hard or soft coatings which are opaque to visible light
More Information Top
-
Novel applications of thermal imaging in the steel industry
Advantages of NIR CCD thermal imaging systems for steel industry applications can be summarised as follows: .
-
Performance of 4x5120 Element Visible and 2x2560 Element Shortwave Infrared Multispectral Focal Planes
Processed VIS / NIR CCDs with the substrate thinned were aligned and bonded to glass support plates on which the patterned mask had been deposited.
-
In-situ temperature measurements of Joule-heated graphene using near-infrared CCD imaging system
A hand-made, in-situ experimental setup consists of an IR microscope, a NIR CCD , and an image enhancer.
-
Diverse electron-induced optical emissions from space observatory materials at low temperatures
Sustained glow, arcs, and flares were all detected in the electrometer, oscilloscope, Vis SLR camera, Vis/ NIR CCD video camera, and NIR InGaAs video camera; coincidence was almost always seen, except when the signals were below detection thresholds for specific instruments.
-
Dorsal hand vein recognition based on 2D Gabor filters
An NIR CCD camera was used to acquire dorsal hand vein images.
-
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010
The first one is system with NIR CCD camera (Near Infra Red), which measure the wide changes of the blood vessels and the second one is system, which measure the pulse transmit time (PTT).
-
NIR Bioimaging: Development of Liposome‐Encapsulated, Rare‐Earth‐Doped Y 2 O 3 Nanoparticles as Fluorescent Probes
Figure 3(d) shows the NIR fluorescence image at 1550 nm, which was observed by an NIR CCD camera.
-
Polyscale technology for developing near infrared fluorescence bioimaging system based on novel synthese approaches for rare-earth doped nanophspors
… the UC-FBI system is the technol- ogy to be used immediately by changing the excitation light into the NIR laser diode, while the NIR-FBI is future oriented technology with less scattering and higher emission efficiency by introducing the NIR CCD .
-
World Congress on Medical Physics and Biomedical Engineering 2006
The non-contact detection system is constructed with dual NIR CCD cameras and multiple lens system.
-
Photometric search for variable stars in young open cluster Berkeley 59
Fig. 6 shows NIR CCD for the .
Indicates content that may require registration and/or purchase.