Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Edmund Optics Inc.
Description: AT-140 and AT-200 Provide Unmatched Color Fidelity AD-081 Features High Dynamic Range Imaging AD-080 Allows Simultaneous Visible and NIR Imaging The JAI AT-140 and AT-200 CCD cameras achieve unmatched color fidelity by utilizing three sensors individually
- Imaging Technology / Camera Type: CCD
- Sensitivity: 0.5000 Lux
-
Supplier: Edmund Optics Inc.
Description: AT-140 and AT-200 Provide Unmatched Color Fidelity AD-081 Features High Dynamic Range Imaging AD-080 Allows Simultaneous Visible and NIR Imaging The JAI AT-140 and AT-200 CCD cameras achieve unmatched color fidelity by utilizing three sensors individually
- Imaging Technology / Camera Type: CCD
- Sensitivity: 1.4 Lux
-
Supplier: Edmund Optics Inc.
Description: AT-140 and AT-200 Provide Unmatched Color Fidelity AD-081 Features High Dynamic Range Imaging AD-080 Allows Simultaneous Visible and NIR Imaging The JAI AT-140 and AT-200 CCD cameras achieve unmatched color fidelity by utilizing three sensors individually
- Imaging Technology / Camera Type: CCD
- Sensitivity: 1.1 Lux
-
-
Supplier: Edmund Optics Inc.
Description: AT-140 and AT-200 Provide Unmatched Color Fidelity AD-081 Features High Dynamic Range Imaging AD-080 Allows Simultaneous Visible and NIR Imaging The JAI AT-140 and AT-200 CCD cameras achieve unmatched color fidelity by utilizing three sensors individually
- Imaging Technology / Camera Type: CCD
- Sensitivity: 0.3400 Lux
-
Supplier: Vision Components GmbH
Description: accessed remotely. VC Professional Smart Cameras are amongst others the better choice for barcode or DMC decoding and object recognition. 2/3" CCD sensor resolution 1280 x 1024 Pixel frame rate 14 fps Near Infra Red wave lengths up to 1100 nm high-speed shutter: up to 5 µs low-speed shutter:
- Camera Function: Video
- Imaging Technology / Camera Type: Smart Camera
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-8000 is designed for 900-2600nm NIR, miniature optic fiber spectrometer. It employs 256/512 pixels cooled InGaAs Array, semiconductor cooling technology CCD, cooled down to -20ºC under constant operating temperature, resulting in low noise, 2 times SNR higher than competitors
- Computer Interface Options: Serial Interface
- Detector Type: Charge Coupled Device (CCD)
- Display Options: None
- Operating Temperature: 32 to 122 F
-
UV and Visible Spectrometers - Nebula NIR VI mini spectrometer 500-700nm 2048CCD detector -- OSP0407Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Spectral Resolution: 1 nm
- Stray Light: 0.1000 %
- Wavelength Range: 500 to 700 nm
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Spectral Resolution: 1 nm
- Stray Light: 0.1000 %
- Wavelength Range: 550 to 840 nm
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Spectral Resolution: 1 nm
- Stray Light: 0.1000 %
- Wavelength Range: 600 to 1000 nm
-
Supplier: Knight Optical (UK) Ltd
Description: Knight Optical's Nebula VIS fiber optically coupled mini spectrometer is designed for high performance measurements of the VIS spectrum between 0.35-1.15nm. The system uses a highly sensitive CCD detector with 2048 pixels to maximize measurement accuracy, fitted with a fast USB interface to
- Spectral Resolution: 1 nm
- Stray Light: 0.1000 %
- Wavelength Range: 600 to 800 nm
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Application Software Included: Yes
- Detector Type: Charge Coupled Device (CCD)
- Light Source: Other Method
- Operating Temperature: 32 to 104 F
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Application Software Included: Yes
- Detector Type: Charge Coupled Device (CCD)
- Light Source: Other Method
- Operating Temperature: 32 to 104 F
-
Supplier: Electro Optical Components, Inc.
Description: EOC-SI-9000, 9010, 9020 are a compact, lightweight, and miniature hyperspectral imager, and it's especially applied to drones. EOC-SI-9000 employs high spatial resolution, spectral resolution, wide imaging range etc. EOC-SI-9000 consist of two parts, one part is imaging camera lens, the other part
- Application Software Included: Yes
- Detector Type: Charge Coupled Device (CCD)
- Light Source: Other Method
- Operating Temperature: 32 to 104 F
-
Atomic Emission and Optical Emission Spectrometers - GREEN-Wave Mini Fiber Optic Spectrometer -- NIRSupplier: StellarNet, Inc.
Description: The StellarNet GREEN-Wave low cost Spectrometers are fiber optic coupled instruments with a wide selection of models for measurements in 190-1150nm wavelength ranges. Each unit contains a USB interface with a snap shot memory to provide instantaneous spectral image from the highly sensitive
- Application Software Included: Yes
- Computer Interface: Yes
- Computer Interface Options: Serial Interface
- Data Storage / Data Logger: Yes
-
Supplier: StellarNet, Inc.
Description: sensitive CCD with options for 2048 or 3648 elements. Various models provide a choice of grating range and slit resolutions. New and improved electronics with a high speed 16-bit digitizer allows for fast data acquisition and a signal to noise of 1000:1! Up to 8 units can be daisy
- Application Software Included: Yes
- Computer Interface: Yes
- Computer Interface Options: Serial Interface
- Data Storage / Data Logger: Yes
-
Supplier: Security Camera Warehouse
Description: Sony SCD702NIR Product Key Features 1/3" Sony Super HAD Color CCD 480 TV Lines 0 Lux (23 pieces IR LED on), 66FT IR Distance 3.6mm Lens Vandal Proof IP66 Water Resistance Auto Tracking White Balance, BLC, AGC DC 12V
- Camera Function: Video
-
Supplier: StellarNet, Inc.
Description: The StellarNet GREEN-Wave low cost Spectrometers are fiber optic coupled instruments with a wide selection of models for measurements in 190-1150nm wavelength ranges. Each unit contains a USB interface with a snap shot memory to provide instantaneous spectral image from the highly sensitive
- Application Software Included: Yes
- Computer Interface: Yes
- Features: Automatic Calibration, Data Storage or Data Logging
- Instrument Type: Handheld, Portable
-
Supplier: VAST STOCK CO., LIMITED
Description: Image Sensors PYTHON 2000 NIR
-
Supplier: Allied Vision Technologies GmbH
Description: excellent NIR response for excellent image quality and sensitivity. The GB660 is available with optional vertical connector orientation. Models: GB660, 659x493, 120 fps, CCD, Mono GB660C, 659x493, 120 fps, CCD, Color GB660-V, 659x493, 120 fps, CCD, Mono
- Application / Industry: Industrial, Security / Law Enforcement, Other
- Camera Function: Video
- Features: Anti-blooming, Gain Control, Gamma Correction, Progressive Scan
- Horizontal Resolution: 659 lines
-
Supplier: Allied Vision Technologies GmbH
Description: and excellent NIR response for excellent image quality and sensitivity. Models GS660, 659x493, 120 fps, CCD, Mono GS660C, 659x493, 120 fps, CCD, Color Features include: 120 fps at 659x493 5.6x5.6 um pixel size High Sensitivity Sony ExView HAD sensor
- Application / Industry: Industrial, Security / Law Enforcement, Other
- Camera Function: Video
- Features: Anti-blooming, Gain Control, Gamma Correction, Progressive Scan
- Height: 3.74 inch
-
Supplier: Allied Vision Technologies GmbH
Description: Ultra-compact, inexpensive 0.4 Megapixel camera - interlaced, high sensitivity The Guppy F-044B/C is equipped with an ultra-sensitive interlaced CCD sensor - which makes the move from analog to digital cameras very easy. Additionally, with the Guppy F-044B/C NIR, a version with
- Application / Industry: Industrial, Security / Law Enforcement, Other
- Camera Function: Video
- Features: Gain Control
- Height: 1.18 inch
-
Supplier: VAST STOCK CO., LIMITED
Description: Image Sensors PYTHON 5000 NIR LVDS
-
Supplier: VAST STOCK CO., LIMITED
Description: Image Sensors PYTHON 1300 NIR LVDS
-
Supplier: VAST STOCK CO., LIMITED
Description: Image Sensors PYTHON 300 NIR LVDS
-
Supplier: Allied Vision Technologies GmbH
Description: The GC660 is a fast, VGA-resolution, high-performance machine vision camera with Gigabit Ethernet interface (GigE Vision„¢). The GC660 incorporates a Sony ExView HAD CCD sensor that has particularly high quantum efficiency and excellent NIR response for excellent image quality and
- Application / Industry: Industrial, Security / Law Enforcement, Other
- Camera Function: Video
- Features: Progressive Scan
- Height: 1.5 inch
-
Supplier: Hamamatsu Photonics
Description: Enhanced near infrared sensitivity, Constant element temperature control The S16011 series is a family of back-thinned FFT (full frame transfer)-CCD image sensors for photometric applications that o?er improved sensitivity in the near infrared region at wavelengths longer than 800
- Horizontal Pixels: 1024
- Pixel Size: 14 µm
- Spectral Response: 200 to 1100 nm
- Vertical Pixels: 64
-
Supplier: Hamamatsu Photonics
Description: Enhanced near infrared sensitivity, Constant element temperature control The S16011 series is a family of back-thinned FFT (full frame transfer)-CCD image sensors for photometric applications that o?er improved sensitivity in the near infrared region at wavelengths longer than 800
- Horizontal Pixels: 2048
- Pixel Size: 14 µm
- Spectral Response: 200 to 1100 nm
- Vertical Pixels: 64
-
Supplier: Ophir-Spiricon Inc.
Description: Low cost, compact, high resolution CCD NIR camera
- Computer Host: PC
- Cooling: Uncooled
- Detector Type: Array
- Features & Options: Portable
-
Supplier: Qioptiq
Description: µm Spectral Resolution: VIS 0.5 nm, UV 0.2 nm, NIR 0.3 nm Dynamic Range / SNR: 2000 : 1 (full scale, texp = 1 s) Stray Light: < 0.05 % Exposure Time Range: 100 µs to 600 s Detector: 3648 pixel linear CCD detector (VIS, UV: coated for rnhanced UV
- Application Software Included: Yes
- Computer Interface: Yes
- Detector Type: Charge Coupled Device (CCD)
- Operating Temperature: 5 to 140 F
-
Supplier: Yankee Environmental Systems, Inc.
Description: , dew point, and pressure), a TSP-400 visible/NIR pyranometer (solar), and 2-D wind speed and direction (sonic or wind vane/anemometer). Optional sensors include TSI-880 Automated Total Sky Imagers, UVB-1 or UVA-1 UV pyranometers, TIR-550 IR radiometers, optical visibility and precipitation
-
Supplier: StellarNet, Inc.
Description: SILVER-Nova is the most well rounded spectrometer choice allowing research grade results for numerous spectroscopic applications. The spectrograph employs composite grating technology to deliver high efficiency in both the UV & NIR spectral extremes. The UV enhanced CCD detector with
- Application Software Included: Yes
- Computer Interface Options: Serial Interface
- Cooled Detector: Yes
- Display Options: None
-
Supplier: Daitron Co., Ltd.
Description: %. That of 50mm and 105mm is more than 80%. The following drawing is for 50mm lens. Wide spectral response Bluevision lens series is extended to NIR(Near Infrared) wave length in order to apply newly developed JAI 4CCD series line scan cameras (LQ-200CL,LQ-100CL and LQ-50CL). He
-
Supplier: Daitron Co., Ltd.
Description: %. That of 50mm and 105mm is more than 80%. The following drawing is for 50mm lens. Wide spectral response Bluevision lens series is extended to NIR(Near Infrared) wave length in order to apply newly developed JAI 4CCD series line scan cameras (LQ-200CL,LQ-100CL and LQ-50CL). He
-
Supplier: Daitron Co., Ltd.
Description: %. That of 50mm and 105mm is more than 80%. The following drawing is for 50mm lens. Wide spectral response Bluevision lens series is extended to NIR(Near Infrared) wave length in order to apply newly developed JAI 4CCD series line scan cameras (LQ-200CL,LQ-100CL and LQ-50CL). He
-
Supplier: Daitron Co., Ltd.
Description: than 70%. That of 50mm and 105mm is more than 80%. The following drawing is for 50mm lens. Wide spectral response Bluevision lens series is extended to NIR(Near Infrared) wave length in order to apply newly developed JAI 4CCD series line scan cameras (LQ-200CL,LQ-100CL and LQ-50CL). He
-
Supplier: ASTM International
Description: methods having a broader range than others. Extending these methods to the near infrared (NIR) beyond 830 nm will be discussed briefly, where appropriate. These methods were designed for scanning fluorescence spectrometers with a single channel detector, but can also be used with a
-
Supplier: Yankee Environmental Systems, Inc.
Description: The state-of-the-art Rotating Shadowband Spectroradiometer (RSS) combines a high-performance 1024-pixel CCD spectrograph with an external rotating shadowband similar to that used in our MFR instrument family. It automatically provides instantaneous direct, diffuse, and total irradiance
-
Supplier: ASTM International
Description: some methods having a broader range than others. Extending these methods to the near infrared (NIR) beyond 830 nm will be discussed briefly, where appropriate. These methods were designed for scanning fluorescence spectrometers with a single channel detector, but can also be used with a
Find Suppliers by Category Top
Featured Products Top
-
Hamamatsu Photonics has officially launched the WS Series Mini-Spectrometers, a cutting-edge solution designed to meet the diverse needs of UV to NIR spectroscopy applications. This innovative lineup features two distinct models: the C16449MA-01 and the C16449MA-02. The C16449MA-01 model boasts (read more)
Browse Uncategorized Products Datasheets for Hamamatsu Photonics
Conduct Research Top
-
Using NIR for Inspection Applications
This week, Lumenera is at the SPIE Defense + Commercial Sensing (SPIE DCS) show demonstrating our Lt16059HM, a USB 3.0 industrial grade 16 MP CCD large format monochrome camera with Canon lens and a visible light blocking filter. Using an 850 nm NIR light ring we will be demonstrating how
-
A NIR-to-NIR Upconversion Luminescence System for Security Printing Applications
-to-NIR images are easily captured, however, using an inexpensive, modified point-and-shoot CCD camera, even at modest excitation power densities (1.5 W cm-2). It is demonstrated that the latent images can also be read through select hard or soft coatings which are opaque to visible light
More Information Top
-
Novel applications of thermal imaging in the steel industry
Advantages of NIR CCD thermal imaging systems for steel industry applications can be summarised as follows: .
-
Performance of 4x5120 Element Visible and 2x2560 Element Shortwave Infrared Multispectral Focal Planes
Processed VIS / NIR CCDs with the substrate thinned were aligned and bonded to glass support plates on which the patterned mask had been deposited.
-
In-situ temperature measurements of Joule-heated graphene using near-infrared CCD imaging system
A hand-made, in-situ experimental setup consists of an IR microscope, a NIR CCD , and an image enhancer.
-
Diverse electron-induced optical emissions from space observatory materials at low temperatures
Sustained glow, arcs, and flares were all detected in the electrometer, oscilloscope, Vis SLR camera, Vis/ NIR CCD video camera, and NIR InGaAs video camera; coincidence was almost always seen, except when the signals were below detection thresholds for specific instruments.
-
Dorsal hand vein recognition based on 2D Gabor filters
An NIR CCD camera was used to acquire dorsal hand vein images.
-
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010
The first one is system with NIR CCD camera (Near Infra Red), which measure the wide changes of the blood vessels and the second one is system, which measure the pulse transmit time (PTT).
-
NIR Bioimaging: Development of Liposome‐Encapsulated, Rare‐Earth‐Doped Y 2 O 3 Nanoparticles as Fluorescent Probes
Figure 3(d) shows the NIR fluorescence image at 1550 nm, which was observed by an NIR CCD camera.
-
Polyscale technology for developing near infrared fluorescence bioimaging system based on novel synthese approaches for rare-earth doped nanophspors
… the UC-FBI system is the technol- ogy to be used immediately by changing the excitation light into the NIR laser diode, while the NIR-FBI is future oriented technology with less scattering and higher emission efficiency by introducing the NIR CCD .
-
World Congress on Medical Physics and Biomedical Engineering 2006
The non-contact detection system is constructed with dual NIR CCD cameras and multiple lens system.
-
Photometric search for variable stars in young open cluster Berkeley 59
Fig. 6 shows NIR CCD for the .
Indicates content that may require registration and/or purchase.