Supplier: Qualitrol Company, LLC
Description: The Qualitrol 103 series of Resistance Temperature Devices (RTD) are available with either Pt100 (platinum 100Ω) or Cu10 (copper 10Ω) are used to measure oil and winding temperature . This oil and winding temperature measurement sensor is for use with Qualitrol Thermal Plate products
- Features: RTD
-
Supplier: Qualitrol Company, LLC
Description: measure the oil temperature RTDs enable accurate measurements across an extremely large temperature range Compact remote indication and monitoring RTD output allows for temperature indication where it is most convenient Choose between one or two RTD’s within the same transmitter
- Features: RTD
-
Supplier: Pepperl+Fuchs SE
Description: 4 channels Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc. Installation in Zone 2 or safe area Simulation mode for service operations (forcing) Line fault detection (LFD) Permanently self-monitoring Module can be exchanged under voltage
-
-
Supplier: Transcat, Inc.
Description: keyboard entry or scroll control of output User-defined setpoints High accuracy ±0.4°C J thermocouple and ±0.3 °C PT 100-385 RTDs; all errors included Thirteen (13) thermocouple types and thirteen (13) RTD types including PT 385 (1,000 Ohm) and Cu (10 Ohm) NEMA 4 rated case, rugged
- Environmental Properties: Thermocouple
-
Supplier: GL Communications, Inc.
Description: Ethernet/IP/UDP traffic with on-demand bandwidth (up to 800 Mbps) and measures end to end performance such as Bit Error Rate, Total Packets, Packet loss, Out of Sequence Packets, and Erred Packets. Additional features include transmission of pre-recorded file traffic, GTP traffic simulation,
-
Supplier: Qualitrol Company, LLC
Description: RTD based temperature sensing devices Options Employs a universal probe with adjustable length and various sleeves to adapt to different diameter and length wells 103 series RTD’s are available with either Pt100 (platinum 100Ω) or Cu10 (copper 10Ω) for use with Qualitrol Thermal
-
Supplier: Conax Technologies
Description: measurement with RTD or TC sensor. * Difference, average or redundant temperature measurement with RTD or TC sensor. * Linear resistance, potentiometer and bipolar mV measurement. Technical Characteristics: * Bus transmitter with both PROFIBUS® PA and FOUNDATION™ Fieldbus
- Sensed Temperature: -328 to 4,172 F
- Operating Temperature: -40 to 140 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms
- Other Input: Analog Current, Resistance Input
-
Supplier: Conax Technologies
Description: PROFIBUS® PA Ver. 3.0 FOUNDATION™ Fieldbus Ver. ITK 4.6 Automatic Switch Between Protocols FISCO Certified Basic or LAS Capability with Foundation Fieldbus Complies with European ATEX & CSA/FM Requirements for Hazardous Location Installation Application: Linearized temperature measurement with
- Sensed Temperature: -328 to 4,172 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Features: B, E, J, K, N, Other, R, S, T, W
-
Supplier: Conax Technologies
Description: PROFIBUS® PA Ver. 3.0 FOUNDATION™ Fieldbus Ver. ITK 4.6 Automatic Switch Between Protocols Basic or LAS Capability with Foundation Fieldbus 1- or 2-Channel Version Complies with European ATEX and CSA/FM Requirements for Hazardous Location Application: Linearized temperature measurement with
- Sensed Temperature: -328 to 4,172 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Features: B, E, J, K, N, Other, R, S, T, W
-
Supplier: Conax Technologies
Description: PROFIBUS® PA Ver. 3.0 FOUNDATION™ Fieldbus Ver. ITK 4.6 Automatic Switch Between Protocols Basic or LAS Capability with Foundation Fieldbus Complies with European ATEX and CSA/FM Requirements for Hazardous Location Installation Application: Linearized temperature measurement with RTD or TC
- Sensed Temperature: -328 to 4,172 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Features: B, E, J, K, N, Other, R, S, T, W
-
Supplier: Transcat, Inc.
Description: measurement and simulation of the following parameters: relative and absolute pressure, electrical signals (mA, mV, V, Ω), temperature (TC, RTD), frequency and pulse. In addition, there is the possibility to include an optional HART® module which allows communication with HART®
-
Supplier: Transcat, Inc.
Description: measurement and simulation of the following parameters: relative and absolute pressure, electrical signals (mA, mV, V, Ω), temperature (TC, RTD), frequency and pulse. In addition, there is the possibility to include an optional HART® module which allows communication with HART®
-
Supplier: Transcat, Inc.
Description: measurement and simulation of the following parameters: relative and absolute pressure, electrical signals (mA, mV, V, Ω), temperature (TC, RTD), frequency and pulse. In addition, there is the possibility to include an optional HART® module which allows communication with HART®
-
Supplier: MTI Instruments Inc.
Description: for cabling and wiring troubleshooting, audio signal simulation, machinery speed signal simulation, low-voltage bridge mode (microvolt DC output) sensor signal simulation and gas turbine maintenance, the 1510A produces accurate and precise voltage, charge, and speed signals
- Voltage Range (Output): 9.999 volts
- Voltage Resolution (per Step): 0.0001 volts
- Input Voltage Range: 9.999 volts
- Output Voltage Range: 9.999 volts
-
Supplier: PR electronics
Description: Advanced features Configuration and monitoring by way of detachable display front (PR 4501); process calibration and signal simulation. Copying of the configuration from one device to others of the same type via the display front. TC inputs can use either the internal CJC or a terminal with a
- Operating Temperature: -4 to 140 F
- Application: 4-20 mA 2-wire Transmitters, RTDs, Thermocouples
- Features: ATEX, FM Approval, Other, UL Listed
- Barrier Type: Galvanic Isolator
-
Supplier: SAE International
Description: In the development of internal combustion engines, measurements of the heat transfer to the cylinder walls play an important role. These measurements are necessary to provide data for building a model of the heat transfer, which can be used to further develop simulation tools for engine
-
Supplier: AMETEK Programmable Power
Description: Four Independent Channels Series or Parallel Operation Precision Sensor Simulation Low Thermal Offset (≤±25 µV) Independent Sense Feedback Dynamic Soft Front Panel Interface IVI-COM, IVI-C, LabVIEW™ Drivers 3-Year Warranty Combining AMETEK VTI Instruments' proven industry track record with
- Features: Bus Interface / Adapter
- Technology: PXITM Compliant
Find Suppliers by Category Top
Featured Products Top
-
testing environments. Use cases have included voltage testing and temperature simulation (mV signals seen with RTDs) in Power Hardware in the Loop (P-HIL) configurations. Reliability in High Voltage Environments (read more)
Browse Electrical Voltage Sensors Datasheets for Knick Interface LLC -
-Vacuum Pumps: Often cryopumps or turbomolecular pumps, which achieve the ultra-high vacuum (UHV) levels required for space simulation (10-4 to (read more)
Browse Environmental Test Chambers and Rooms Datasheets for Guangdong Atmars Industry Co., Limited
More Information Top
-
Validating Software in Commercial Smart Transmitter for Safety-Critical Applications
We simulated Pt100 RTD having an input range of 18.56Ω (-2000C) to 390.40Ω (8500C).
-
CR4 - Thread: 4- 20 mA Display
It can also simulate Resistance Output and RTD of types: PT100 , PT200, PT500, PT1000, Cu10, Cu50 of 2-wire, 3-wire and 4-wire.
-
Multifunction Calibrator Now Available From TEK Instrument Company
The Model VC25 can simulate and read 3 types of RTD 's and 8 thermocouples including Type R, S, K, E, J, T, N, and B. RTD's include Pt100 , Pt1000, and Cu50 either 2 wire or 3 wire.
-
Multifunction Calibrator Now Available From TEK Instrument Company
The Model VC25 can simulate and read 3 types of RTD 's and 8 thermocouples including Type R, S, K, E, J, T, N, and B. RTD's include Pt100 , Pt1000, and Cu50 either 2 wire or 3 wire.
-
Sensor technique
Congress band OTTI technology-college Brill M (1988) anwendernahen layers in the ISO-/-OSI model . … June '94 in Paris of firm Beckhoff, S. 77-82, 6/1988, S. 93-96, 8/1988, web Site (2012) www.beckhoff.de, product information to BK3xx0 visit professional bus-bus coupler and KL3204 4-channel input terminal PT100 ( RTD ) in April 2012 Haskard …
-
FPGA implementation of an emulator for Wireless Sensor Node with Pt100 temperature sensor
RTD Pt100 temperature sensor has been used along with ATmega8L as an input to the transmitter. The FPGA implementation of the system and the simulation results of all the modules have been presented …
-
http://assets.fluke.com/appnotes/processtools/1560369_.pdf
8 RTD types PT100 -385 Simulate -200 to 800°C • • .
-
PLC-Based PV Plants Smart Monitoring System: Field Measurements and Uncertainty Estimation
Fig. 9 shows the simulated waveforms of the transmitted data (CH1), the waveform of the data on … This module receives also data from Atersa calibrated and compensated cell (Fig. 1), which supplies information related to global radiation (100 mV at 1000 W/m2) in the plane of the PV panels, as well as ambient temperature given by a PT100 RTD .
-
An evolutionary optimized nonlinear function to improve the linearity of transducer characteristics
To prove the performance of the presented algorithm, it is applied to three different transducers, namely a RTD ( Pt100 with temperature coefficient 0.003 85), a negative temperature coefficient (NTC) thermistor of resistance 2252 . at 25 ◦ C . and a copper–constantan (type … … the signal conditioning circuits shown in figures 2 and 3, respectively, have been simulated and confirmed using …
-
Research and Development of the Remote I/O Data Acquisition System Based on Embedded ARM Platform
… connect to the positive end INPx and the negative end INNx of the simulate multiplexers(MUX) directly. The RTD thermal resistance signals such as Cu50, Cu100, Pt50 and Pt100 should connect one 1mA constant current before connecting to the positive end INPx and the negative end INNx of the MUX of certain channel.
Indicates content that may require registration and/or purchase.