Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: REED-Direct
Description: Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution When measuring a sugar solution, the Brix% should perfectly match the actual concentration With solutions of other components, a conversion chart is required
- Brix Accuracy: 0.0200 ±%
- Brix Range: 28 to 62 %
- Features: Automatic Temperature Compensation
- Measurement Scale: Brix Detector
-
Supplier: REED-Direct
Description: Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution When measuring a sugar solution, the Brix% should perfectly match the actual concentration With solutions of other components, a conversion chart is required
- Brix Accuracy: 0.2000 ±%
- Brix Range: 0.0 to 32 %
- Features: Automatic Temperature Compensation
- Measurement Scale: Brix Detector
-
Supplier: REED-Direct
Description: Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution When measuring a sugar solution, the Brix% should perfectly match the actual concentration With solutions of other components, a conversion chart is required
- Brix Accuracy: 0.1500 ±%
- Brix Range: 0.0 to 18 %
- Features: Automatic Temperature Compensation
- Measurement Scale: Brix Detector
-
-
Supplier: REED-Direct
Description: Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution When measuring a sugar solution, the Brix% should perfectly match the actual concentration With solutions of other components, a conversion chart is required
- Brix Accuracy: 0.0100 ±%
- Brix Range: 0.0 to 10 %
- Features: Automatic Temperature Compensation
- Measurement Scale: Brix Detector
-
Supplier: Vaisala
Description: For semiconductor liquid chemical processes A compact refractometer with an ultra-pure modified PTFE flow cell body for semiconductor liquid chemical processes. Connected to the process by a ¼ — 1 inch pillar or flare fitting. Vaisala K-PATENTS® Semicon
- Features: Alarms, Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector
- Monitoring: Continuous
- Mounting: Permanent or Fixtured
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: Sartorius Process Refractometers Monitoring and control of process streams is vital for achieving optimal product quality. Rapid, reliable, und exact determination of the concentration, identity, and purity of the components in your process stream is a crucial part of effective process
- Form Factor: Monitoring System
- Instrument Type: Material Condition
- Technology: Optical / Laser
Find Suppliers by Category Top
Featured Products Top
-
coolant with a refractometer. Since the numbers on the dial may not directly correspond to your desired output, it’s important to test the concentration using a refractometer. The Venturi-style mixers are suitable for companies using a few drums (read more)
Browse Metalworking Lubricants, Coolants, and Fluids Datasheets for QualiChem, Inc.
Conduct Research Top
-
Concentration Measurement
The "concentration" of a CIMCOOL (R) Metalworking Fluid is the measurement of specific parameters or components in the product. For a given product there can be several different measurements of "concentration" that provide different numbers. Many times it is important to test concentration
More Information Top
-
Laser interference refractometer for investigating water surface layers
When making measurements of this kind it is naturally necessary to isolate the laser interference refractometer components submerged in the water, and performing the function of primary conversion of the monitored information, and to transmit the measured information to the devices for …
-
Physicochemical Study of n -Ethylpyridinium bis(trifluoromethylsulfonyl)imide Ionic Liquid
The temperature of the sample was controlled within ±0.01 K by a built-in Peltier device, while another Peltier thermostat was used to keep the internal temperature of the refrac- tometer components constant.
-
Experimental and Theoretical Study of Two Pyridinium-Based Ionic Liquids
The temperature of the sample was controlled within ±0.01 K by a built-in Peltier device, while another Peltier thermostat was used to keep constant the temperature of the internal refrac- tometer components .
-
Refractive Indices of the Ternary Mixtures Butanol + n -Hexane + 1-Chlorobutane
The temperature of the sample and of the prism was controlled within ±0.002 K by a built-in Peltier device, and a second Peltier thermostat was used to keep the temperature of internal refractometer components constant in order to increase the …
-
Volumetric
and refractive properties of binary mixtures containing 1,3-dioxolane and
isomeric chlorobutanes
The temperature of the sample is con- trolled within ±2·10–3 K by a built-in Peltier device while another Peltier thermostat is used to kept con- stant the temperature of the internal refractometer components .
-
New low-index liquid refractive index standard: SRM 1922
To serve as an effective refractive index standard, the candidate ma- terial must be compositionally stable, optically and compositionally homogeneous, and non-corrosive with respect to typical refractome- ter components .
-
Building world-class microlithographic lens systems: optical material requirements and qualification methods
Figure 4.1 Refractometer component diagram.
-
Over the protein content of the blood in the infancy with special consideration of tuberculosis
obachtungen came h6ehstens of differences yon 0,05 refractometer partial bars zutage make therefore a wodureh very grol ~ e accuracy aware is.
-
Clinical and experimental contributions to the Ulcusfrage. II
DiG Durehsehnittsrefraktometerzahl falls far every degree (0,1) reduced salt-s-~-urebindungsvermSgens regelreeht refractometer partial bars about about 2,2 what in eggs lingering 3 percent umgereehnet ever about 0,5 Proz. entsprieht.
-
The Nachinaktivierung of irradiated Saccharum maritime solutions and the influence of added tryptophan and yeast rubbers
The in the tables of ange, gebenen numbers present this Xnderung in refractometer partial bars (Sk. T.).
Indicates content that may require registration and/or purchase.