Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: The spirometer is applied to patients who need lung function measurement. Adopting ultrasonic technology, it is a high-tech product used for pulmonary ventilation function and vital capacity. It is a powerful measurement device for asthma checking, COPD and other respiratory diseases,
-
Supplier: Accuris
Description: Standard Test Method for Determining the Aerobic, Aquatic Biodegradability of Lubricants or Lubricant Components in a Closed Respirometer
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR DETERMINING THE AEROBIC, AQUATIC BIODEGRADABILITY OF LUBRICANTS OR LUBRICANT COMPONENTS IN A CLOSED RESPIROMETER - INCLUDES STANDARD + REDLINE (PDF)
-
-
Description: ISO 17556:2012 specifies a method for determining the ultimate aerobic biodegradability of plastic materials in soil by measuring the oxygen demand in a closed respirometer or the amount of carbon dioxide evolved. The method is designed to yield an optimum degree of biodegradation by
-
Supplier: ASTM International
Description: in a closed respirometer. 1.2 This test method is suitable for evaluating the biodegradation of volatile as well as nonvolatile lubricants or lubricant components. 1.3 This test method is applicable to lubricants and lubricant components which are not toxic and not inhibitory to the
-
Supplier: ASTM International
Description: in a closed respirometer. 1.2 This test method is suitable for evaluating the biodegradation of volatile as well as nonvolatile lubricants or lubricant components. 1.3 This test method is applicable to lubricants and lubricant components which are not toxic and not
-
Supplier: ASTM International
Description: in a closed respirometer. 1.2 This test method is suitable for evaluating the biodegradation of volatile as well as nonvolatile lubricants or lubricant components. 1.3 This test method is applicable to lubricants and lubricant components which are not toxic and not inhibitory to the
-
Supplier: ASTM International
Description: in a closed respirometer. 1.2 This test method is suitable for evaluating the biodegradation of volatile as well as nonvolatile lubricants or lubricant components. 1.3 This test method is applicable to lubricants and lubricant components which are not toxic and not inhibitory to the
-
Supplier: CSA Group
Description: ISO 18830:2016 specifies a test method to determine the degree and rate of aerobic biodegradation of plastic materials when settled on marine sandy sediment at the interface between seawater and the seafloor, by measuring the oxygen demand in a closed respirometer. Measurement of aerobic
-
Supplier: CSA Group
Description: ISO 17556:2012 specifies a method for determining the ultimate aerobic biodegradability of plastic materials in soil by measuring the oxygen demand in a closed respirometer or the amount of carbon dioxide evolved. The method is designed to yield an optimum degree of biodegradation by
-
Supplier: CO2Meter.com
Description: The TecMicro O2-Oxygen Sensors are chemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. They are incredibly sought after for breweries, modified atmosphere packaging
- Specific Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: The TecMicro O2-Oxygen Sensors are chemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. They are incredibly sought after for breweries, modified atmosphere packaging
- Specific Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: The TecMicro O2-Oxygen Sensors are chemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. They are incredibly sought after for breweries, modified atmosphere packaging
- Specific Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: The TecMicro O2-Oxygen Sensors are chemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. They are incredibly sought after for breweries, modified atmosphere packaging
- Specific Gas Types: Oxygen (O2)
More Information Top
-
Experimental and modelling data contradict the idea of respiratory down‐regulation in plant tissues at an internal [O 2 ] substantially above the critical oxyg...
… root segments showed a two‐phase reduction in respiration rate starting at/above 21 kPa O2 in the respirometer medium.
-
Measurements of aerobic metabolism of a school of horse mackerel at different swimming speeds
… same school was trained to swim with projected light patterns within a 10‐m diameter annular doughnut respirometer .
-
Thermal aging of the polyurethane foam for the H1259
storage container.
We have adapted a commercial respirometer , used for measuring respiration of small biological organisms, to measure the …
-
The role of body surfaces and ventilation in gas exchange of the abalone, Haliotis iris
… of the epipodium and foot to whole body oxygen requirements were identified using a two-chamber respirometer .
-
The Use of Electromyogram (EMG) Telemetry to Assess Swimming Activity and Energy Use of Adult Spring Chinook Salmon Migrating through the Tailraces, Fishways, ...
The following sections describe respirometer trials of adult spring chinook salmon Ucrit and EMG swim speed trials …
-
Decomposition of elephant dung in an arid, tropical environment
… Carbon dioxide evolution from elephant dung and soil was measured using the absorption respirometers described by Anderson …
-
Some errors in respirometry of aquatic breathers: How to avoid and correct for them
… l.mmHg - I); Cwo~,in: concentration of oxygen in water flowing into the respirometer (mg O~.I …
-
An experimental set-up to analyse the oxygen consumption of elastomers during ageing by using a differential oxygen analyser
Therefore, a respirometer offers the potential to detect the smallest amounts of oxygen changes in the polymers’ …
-
Aerobic scope predicts dominance during early life in a tropical damselfish
… rate in isolation and while interacting with their previous competitor or a stranger in adjacent transparent respirometers .
-
Swimming Physiology of Fish
… optimum can be calculated from oxygen measurements over a range of swimming speeds in a swimming respirometer .
Indicates content that may require registration and/or purchase.