-
Supplier: icotek GmbH
Description: QVT is a circular split cable gland for quick and easy installation and sealing (IP54) of pre-terminated cables or complete cable harnesses. The QVT range is especially suitable for small machines, devices and instruments due to its extremly small structure.
- Opening Diameter: 0.1181103 to 0.5905515 inch
- Temperature Range: -22 to 212 F
- Application: Cable & Wire
- Features: Other
-
Supplier: Automation24, Inc.
Description: The splittable cable gland UNI Split Gland USG 22554 PC from Pflitsch in size M25 x 1.5 offers with a multitude of various applications the possibility to insert one or more pre-assembled cables through a single hole. Moreover, the splittable cable
- Mounting Size: 0.9842525 inch
- Temperature Range: -4 to 176 F
- Application: Cable & Wire
- Features: Other
-
Supplier: Automation24, Inc.
Description: The splittable cable gland UNI Split Gland USG 23255 PC from Pflitsch in size M32 x 1.5 offers with a multitude of various applications the possibility to insert one or more pre-assembled cables through a single hole. Moreover, the splittable cable
- Mounting Size: 1.2598432 inch
- Temperature Range: -4 to 176 F
- Application: Cable & Wire
- Features: Other
-
-
Supplier: Automation24, Inc.
Description: The splittable cable gland UNI Split Gland USG 22053 PC from Pflitsch in size M20 x 1.5 offers with a multitude of various applications the possibility to insert one or more pre-assembled cables through a single hole. Moreover, the splittable cable
- Mounting Size: 0.787402 inch
- Temperature Range: -4 to 176 F
- Application: Cable & Wire
- Features: Other
-
Supplier: Takachi Electronics Enclosure Co., Ltd.
Description: Split type sealing insert can protect cables with connector. Selectable from M25 and M32 thread size. Suitable for φ5mm~φ6.5mm and φ7.5mm~φ10.5mm cables. Color : Available from Black and Light gray Protection class : Equivalent to IP67 (In-house test) Operating temperature :
- Mounting Size: 0.9842525 to 1.2598432 inch
- Number of Wires: 1 #
- Opening Diameter: 0.9842525 to 1.2598432 inch
- Temperature Range: -4 to 176 F
-
Supplier: icotek Corp
Description: compact design, the QVT range is especially suitable for small machines, devices and instruments. The cable glands are easy to install. The prefabricated cable is placed into the slit grommet which is set into one of the gland halves. Depending on the size of the
- Number of Wires: 2 #
- Opening Diameter: 0.4330711 inch
- Temperature Range: -22 to 212 F
- Number of Elements: 2 #
-
Sealing Glands - Split Hood Cable Gland, 6Mm To 7Mm, Polycarbonate; Product Range Harting -- 04C8062Supplier: Newark, An Avnet Company
Description: SPLIT HOOD CABLE GLAND, 6MM TO 7MM, POLYCARBONATE; Product Range:-; Thread Size - Imperial:-; Thread Size - Metric:-; Cable Gland Material:Thermoplastic; Gland Colour:Black; Cable Diameter Min:6mm; Cable Diameter Max:7mm RoHS Compliant: Yes
-
Supplier: icotek Corp
Description: or machinery) and sealed with IP54 / UL Type 12. The cable glands are easy to install. The prefabricated cable is placed into the slit grommet which is set into one of the gland halves. Depending on the size of the cable gland, one, two or four separate
- Number of Wires: 4 #
- Opening Diameter: 0.6692917 inch
- Temperature Range: -22 to 212 F
- Number of Elements: 4 #
-
Supplier: Galco Industrial Electronics
Description: Split Cable Gland, M25, Gray,
- Application: Cable & Wire
-
Supplier: icotek Corp
Description: The KVT-EMC brackets in combination with the split cable glands KVT and QVT combine routing, EMC shield grounding and strain relief. The connection to the ground potential is possible via the enclosure wall or an grounding tape. Cables pass through the split
- Diameter: 0.1181103 inch
- Features: Other
- Material: Steel
-
Supplier: icotek Corp
Description: For round metric cut-outs M32/M50 icotek offers the split cable gland with brush strips KEL-BES-S round. It can be either directly snapped into the cut-out or screwed with a locknut, which is included in the shipment. Split cable glands with brush strips
- Temperature Range: -4 to 194 F
- Application: Cable & Wire
- Features: Other
-
Supplier: icotek GmbH
Description: The KVT-EMC brackets in combination with the split cable glands KVT and QVT combine routing, EMC shielding and strain relief. Cables pass through the split cable glands and lead directly into the EMC clamps. Separte functions according to regulations
- Diameter: 0.05905515 to 0.4330711 inch
- Number of Wires: 1 #
- Features: EMI / RFI Shielding
- Material: Steel
-
Supplier: Newark, An Avnet Company
Description: HAN SPLIT HOOD CABLE ENTRY; Product Range:-; Thread Size - Imperial:-; Thread Size - Metric:-; Cable Gland Material:Thermoplastic; Gland Colour:Black; Cable Diameter Min:15mm; Cable Diameter Max:16mm; IP / NEMA Rating:Not Rated RoHS Compliant: Yes
-
Supplier: Automation24, Inc.
Description: The splittable cable gland system UNI Flange UFLG3 54U from Pflitsch is a well thought out product solution for several pre-assembled cables to pass through. The two-piece grey frame plate made of PA can be installed in a standard sheet metal cut-out of 112 mm x 36 mm for 24-pin
- Mounting Size: 0.9842525 inch
- Temperature Range: -4 to 176 F
- Application: Cable & Wire
- Material: Nylon / Polyamide
-
Supplier: Radwell International
Description: SENSOR DISTRIBUTION BOX, BNC CONN, 4PORT; INPUT CONNECTION TYPE:CABLE GLAND; OUTPUT TYPE:BNC CONNECTOR; NO. OF OUTPUT PORTS:4PORTS; PRODUCT RANGE:CB SERIES; IP RATING:IP66; NO. OF PORTS:4PORTS. FREE 2 YEAR RADWELL WARRANTY
- Application: Cable & Wire
-
Supplier: TelephoneStuff.com
Description: Split Rod Support Grips are designed for loads up to 500 lbs. and vertical runs of no more than 100 feet. They are available in a variety of eye styles and cable ranges for supporting electrical cable, metal rods, and tubing. Split rod support grips are utilized when the
- Application: Cable & Wire
-
Supplier: DigiKey
Description: CABLE GLAND M25 WITH SPLIT INSER
- Temperature Range: -40 to 158 F
- Application: Cable & Wire
- Material: Nylon / Polyamide
-
Supplier: Conax Technologies
Description: Conax Technologies offers three models of split glands designed to facilitate assembly and sealant replacement when the diameter of the probe tip is larger than the diameter of the element(s) at the location of the seal. Split glands provide split sealants,
- Mounting Size: 0.25 to 1.05 inch
- Number of Elements: 1 #
- Opening Diameter: 0.062 to 0.5 inch
- Pressure Rating: 10,007.6013 psi
-
Supplier: Conax Technologies
Description: 10,000 PSI (690 bar) Application Ideas: Use wherever the total diameter of the probe tip(s) being sealed exceeds the diameter of the sealing orifices (i.e. cable assemblies with factory assembled connectors).
- Mounting Size: 0.25 to 1.05 inch
- Number of Wires: 1 #
- Opening Diameter: 0.02 to 0.25 inch
- Pressure Rating: 10,007.6013 psi
-
Supplier: icotek GmbH
Description: Self-centering knockout punches for mild steel, aluminum and plastic walls with max. sheet thickness of 3 mm. Punches are available for metric cut-outs M16, M20, M25, M32, M40, M50 and M63. For cut-outs for all icotek split cable glands and round cable entry plates. The
- Shank Diameter: 0.63779562 to 2.50000135 inch
- Type: Regular / Solid Punch
- Shapes: Round
Find Suppliers by Category Top
Featured Products Top
-
cable and harness assemblies for a broad range of industries, including applications across the Oil & Gas and (read more)
Browse Cable Glands Datasheets for Conax Technologies -
range of power industry applications. Our customers consistently count on Conax to provide standard cable gland solutions, as well as innovative, customized fittings and feedthroughs that are specially designed to meet their needs. The Conax difference: soft sealant (read more)
Browse Datasheets for Conax Technologies -
optic feedthrough (FSA). The fiber optic cable is encased within a rugged stainless steel sheath that protects the cable from damage during the sealing process. The sheath is then placed through a seal fitting (also known as a sealing gland), allowing the fiber optic cable to be sealed without (read more)
Browse Feedthroughs Datasheets for Conax Technologies
More Information Top
-
Electrical Safety: a guide to causes and prevention of hazards
Boots on cable glands split or disturbed .
-
A Review and Analysis of Equipment for Running Electrical Cables Under Pressure
Another type (Fig. 1) was developed using split glands and a screw feed to force rubber into the cable from the side rather than from the top.
Indicates content that may require registration and/or purchase.