Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Gemu Valves
Description: Plastic flowmeter which operates according to the variable area principle with integral metering orifice, housing material: polysulfone. The float is made of PVC-U or PP which can also be fitted with a magnet for electrical detection of the flow rate. Dovetail sections
- Liquid Volumetric Flow Rate: 13.21 to 220 GPM
- Aggressive / Corrosive Process Media: Yes
- End Fittings: Flanged, Socket Weld / Union
- Operating Pressure: 145 psi
-
Supplier: Clark Solutions
Description: possible to mount the flow meter in any orientation. The strong spring, combined with an orifice in the float, limit the effects of viscosity changes to an absolute minimum compared to regular variable area flow meters.
- Liquid Volumetric Flow Rate: 0.0264 to 23.76 GPM
- Electrical Output: Switch
- End Fittings: Threaded
- Media Temperature Range: Up to 248 F
-
Supplier: Clark Solutions
Description: possible to mount the flow meter in any orientation. The strong spring, combined with an orifice in the float, limit the effects of viscosity changes to an absolute minimum compared to regular variable area flow meters.
- Liquid Volumetric Flow Rate: 0.2112 to 23.76 GPM
- Electrical Output: Switch
- End Fittings: Threaded
- Media Temperature Range: Up to 248 F
-
-
Supplier: Orange Research, Inc.
Description: solid blocks of metal, they handle high-pressure applications of up to 5000 psi (vs 150 psi for rotameters). This makes them a natural for hydraulic and pneumatic systems. These variable-area models are designed for medium- to high-flow applications. The sensor, a movable Delrin cone,
- Liquid Volumetric Flow Rate: 0.0 to 4 GPM
- End Fittings: Threaded
- Media Temperature Range: 200 F
- Operating Pressure: 3000 psi
-
Supplier: Technical Toolboxes, Inc.
Description: variables. The Process Hydraulics Toolbox is equally well suited for applications ranging from a single pipe to complex networks where the flow rate in all or part of the network is unknown. The Process Hydraulics Toolbox is used by many engineering companies, contracting
- Deployment: Web-Based
- Source Code: Proprietary
- Use: Professional
-
Supplier: Bell & Gossett, a xylem brand
Description: The Circuit Sensor Flow Meter is a precision machined wafer-type orifice insert that is installed between standard 125, 150, 250 or 300 psi ANSI flanges, to monitor system flow with a minimum friction head loss. System flow is determined by obtaining a differential
- End Fittings: Flanged, Other
- Operating Temperature: 250 F
- Pipe Diameter: 2.5 to 12 inch
- Process Media Type: Liquid
-
Supplier: Daniel Measurement and Control Inc.
Description: Daniel orifice plates conform to the most stringent manufacturing processes to achieve optimum accuracy standards in the industry. They are the most commonly used method of differential pressure flow measurement due to their simplicity, predictable and reliable performance, ease of
- End Fittings: Plain End
- Process Media Type: Gas
- Type: Orifice Plate
-
Supplier: ABB Measurement & Analytics
Description: OriMaster is supplied in two versions – one for volumetric flow and one for mass (or corrected volume) flow. Data One-stop source for the complete orifice meter package – Purchase all the components from one supplier using a single ordering code, saving
- Electrical Output: Analog Current
- End Fittings: Flanged
- Features: Measures Temperature, Audible or Visual Alarms
- Media Temperature Range: -382 to -4 F
-
Supplier: ABB Measurement & Analytics
Description: in two versions – one for volumetric flow and one for mass (or corrected volume) flow. Versatile metering package for low flowrates and small pipelines – Available with or without upstream/downstream pipework; wide choice of orifice plate bores gives a range of DP
- Electrical Output: Analog Current
- End Fittings: Flanged
- Features: Averaging / Multi-Insertion
- Operating Pressure: 1500 to 3000 psi
-
Supplier: Madden Manufacturing, Inc.
Description: The Madden Orifice Meter gives the boiler operator precise repeatable control of the continuous blowdown flow rate. 17 different hole sizes are drilled in the stainless steel orifice plate. Each hole is precision drilled to a diameter that will produce the flow
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights 3/4" line size 0.400" bore 0.49 Beta water capacity: 100" d.p. W/C, 5.69 GPM flow air capacity: 20.21 SCFM @ 14.7 psia, 32.44 SCFM @ 20 psig, 60.26 SCFM @ 100 psig
- Pipe Diameter: 0.7500 inch
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights Mounted with standard flanges Standard "corner tap" configuration Corrosion free material Simplified installation Built in metering taps (1/4" female NPT STD) Proven through a wide range of applications for accuracy and
- Operating Pressure: 3.61 psi
- Pipe Diameter: 16 inch
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights Mounted with standard flanges Standard "corner tap" configuration Corrosion free material Simplified installation Built in metering taps (1/4" female NPT STD) Proven through a wide range of applications for accuracy and
- Operating Pressure: 0.7225 psi
- Pipe Diameter: 6 inch
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights 3" line size 2.150" bore 0.7 Beta water capacity: 320" d.p. W/C, 324.16 GPM flow air capacity: 816.7 SCFM @ 14.7 psia, 1404.95 SCFM @ 20 psig, 2696.28 SCFM @ 100 psig
- Pipe Diameter: 3 inch
- Type: Orifice Plate
-
Supplier: Victaulic Co. of America
Description: ORIFICE TYPE 406 C FLOW RATE 12 INCH NOMINAL SIZE 12 NOMINAL SIZE - DECIMAL 12 NOMINAL SIZE - FRACTIONAL CARBON STEEL BODY MATERIAL 250 PSI WATER AT 230 DEG F PRESSURE RATING 12 INCH IPS GROOVED X 12 INCH IPS GROOVED END CONNECTION 5 INCH END TO END DISTANCE APPROXIMATE WEIGHT 21.2 LB
- Operating Pressure: 250 psi
- Pipe Diameter: 12 inch
- Type: Orifice Plate
-
Supplier: Victaulic Co. of America
Description: ORIFICE TYPE 269 C FLOW RATE 10 INCH NOMINAL SIZE 10 NOMINAL SIZE - DECIMAL 10 NOMINAL SIZE - FRACTIONAL CARBON STEEL BODY MATERIAL 250 PSI WATER AT 230 DEG F PRESSURE RATING 10 INCH IPS GROOVED X 10 INCH IPS GROOVED END CONNECTION 5 INCH END TO END DISTANCE APPROXIMATE WEIGHT 17 LB
- Operating Pressure: 250 psi
- Type: Orifice Plate
-
Supplier: Clark Solutions
Description: Use the 7000/8000 series flow meters for measuring the flow rate of liquids, gases, compressed air and steam in closed pipes. We also make indicating flow switches and flow transmitters for process indication and control. Meters feature a large easy to read
- Gas Volumetric Flow Rate: 0.1667 to 66.67 SCFM
- Liquid Volumetric Flow Rate: 2 to 500 GPM
- Electrical Output: Analog Current, Frequency, Switch
- End Fittings: Threaded, Other
-
Supplier: Clark Solutions
Description: FLO-GARD™ flow switches provide economical solutions for equipment protection and automation. All FLO-GARD™ flow switches provide high reliability design with no paddles or small flow paths to plug or stick. Switches are suitable for measuring oil and water containing
- Liquid Volumetric Flow Rate: 0.0083 to 3000 GPM
- Electrical Output: Switch
- End Fittings: Threaded
- Media Temperature Range: -80 to 212 F
Find Suppliers by Category Top
Featured Products Top
-
over time, which requires maintenance to maintain accuracy. For maintenance, orifice plate meters require either a bypass line around the meter or shutting down the gas compressor when pulling the orifice plate out of the line to perform maintenance. The Wafer-Cone Flow Meter relies on unique (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
-Cone reduces permanent pressure loss by 75% compared to a traditional orifice plate. In addition, steam flooding requires multiple meters to monitor the process that must operate over the life of the field with low maintenance requirements to make the operation cost-effective. The V-Cone Flow Meter (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
Engineers in search of a reliable solution for wellhead gas flow measurement will find that the flexible Wafer-Cone® Flow Meter from McCrometer provides good accuracy (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
refining industry. The testing of the V-Cone Flow Meter now conforms to the American Petroleum Institute's API 22.2 Testing Protocol for differential pressure flow measurement devices. In comparison to traditional DP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
refining industry. The testing of the V-Cone Flow Meter now conforms to the American Petroleum Institute's API 22.2 Testing Protocol for differential pressure flow measurement devices. In comparison to traditional DP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
fluid flow and reshapes the velocity profile to create a lower pressure region immediately downstream. Unlike traditional DP instruments, such as orifice plates and venturi tubes, the V-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built-into the (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
. Unlike traditional dP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built into the unique sensor design. The V-Cone Flow Meter's centrally located cone interacts with the fluid steam (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
. Unlike traditional dP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built into the unique sensor design. The V-Cone Flow Meter's centrally located cone interacts with the fluid steam (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
The Lee Company's new VILA is an economical, multi-orifice restrictor designed to offer a range of metered Lohm rates for high flow applications. Rated for working pressures up to 1500 psi differential, the VILA is constructed entirely from 2024-T4 aluminum, resulting in a robust design that is (read more)
Browse Flow Orifices and Flow Restrictors Datasheets for Lee Co. (The) -
Sierra was the first to introduce multivariable mass vortex flow meters to the market in the late 1990s with the InnovaMass "S-Series" product line-the 240S and (read more)
Browse Flow Meters Datasheets for Sierra Instruments, Inc.
Conduct Research Top
-
Flow Energy Management Part 3: Three Successful Flow Energy Management Case Studies
by using one meter with one process connection to measure up to five process variables - volumetric flow rate, mass flow, density, pressure and temperature. Decrease in downtime and installation costs by hot tapping meter with the onboard retractor. Onboard software apps with meter tuning
-
Adhesive Dispensing Units Manufactured by Johnstone Dispensing Systems
on the other side. The material is conditioned to a constant temperature, within a tenth of a degree, in order to maintain a constant viscosity. Desired flow is achieved using a variable pressure and specific orifice size. On an automotive enclosure, for example a hood, the dispenser robot moves across
More Information Top
-
Monitoring Technologies in Acute Care Environments
Inspiratory flow is measured with a variable orifice flow meter , and bellows descent terminates when inspired tidal volume reaches set tidal vol- ume.
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-1793 - Final Safety Evalu...
Vortex shedding flow meter, variable orifice flow meter , rate of condensate collection Steam inlet pressure .
-
The automatic selection of ventilation parameters during the initial phase of mechanical ventilation
In six cases, a Hamilton variable orifice flow meter instead of the screen pneumotachograph was used for technical reasons.
-
Intelligent valves and actuators
A second area of interest with an intelligent valve is to use it as a variable orifice flow meter .
-
Effect of altitude on spirometric parameters and the performance of peak flow meters.
Variable orifice peak flow meters grossly underestimate PEF at altitude and fixed orifice devices are therefore preferable where accurate PEF measurements are required above sea level.
-
Frequency response of variable orifice type peak flow meters: requirements and testing.
Little is known about the response of variable orifice peak flow meters to high frequency flow input.
-
CR4 - Thread: Rotameters(cone +float) A Very Bad Idea For Use In Closed Loops
If I understand the OP correctly, there is a variable orifice flow - meter sensing the flow into a downstream back-pressure control valve while at the same time attempting to control the output of the same valve.
Indicates content that may require registration and/or purchase.