Help with Dial Thermometers specifications:
Display/Scale Characteristics
Back to Top
|
|
| ||
| Scale | |||
| Your choices are... | |||
| Fahrenheit | Dial/display graduated in these units. | ||
| Celsius | Dial/display graduated in these units. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Fahrenheit Scale | |||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Fahrenheit Scale Divisions: | Scale division describes the smallest division of degrees that can be displayed on the thermometer. This affects the accuracy of the temperature reading. | ||
| Search Logic: | All matching products will have a value less than or equal to the specified value. | ||
| Celsius Scale | |||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Celsius Scale Divisions | Scale division describes the smallest division of degrees that can be displayed on the thermometer. This affects the accuracy of the temperature reading. | ||
| Search Logic: | All matching products will have a value less than or equal to the specified value. | ||
Technology Type
Back to Top
|
|
| ||
| Analog Technology Type: | |||
| Your choices are... | |||
| Bimetal | Uses a bimetal spring as temperature sensing element. | ||
| Liquid or Gas Actuated (Vapor-Tension or Bellows) | Uses a gas/vapor as temperature sensing element. | ||
| Other | Other unlisted, specialized, or proprietary thermometer. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Dimensions
Back to Top
|
|
| ||
| Dial Diameter | |||
| Search Logic: | User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria. | ||
| Stem Length | The stem length is the overall length of the measuring portion of the thermometer. This will include the insertion part of the stem. | ||
| Search Logic: | User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria. | ||
Application Type
Back to Top
|
|
| ||
| Application Type: | |||
| Your choices are... | |||
| Food service / Sanitary | The thermometer is rated for food service or sanitary use. | ||
| HVAC | Thermometer is rated for HVAC applications such as duct or flume monitoring. | ||
| Industrial | The thermometer is rated for industrial use. | ||
| Laboratory | Often has a clip for temporary mounting to lip of a container, beaker etc. | ||
| Weather / Meteorological | The thermometer is rated for weather or meteorological use. | ||
| Other Special Purpose | Any other unlisted or special purpose. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Configuration/Features
Back to Top
|
|
| ||
| Features | |||
| Your choices are... | |||
| Zero adjustment | Can reset zero point. | ||
| Surface | The thermometer is configured to be used for surface measurements only. | ||
| NPT fitting | The thermometer has an NPT fitting. | ||
| Small and made to carry in pocket. Has a clip and/or sheath. | |||
| Probe | The thermometer has a probe. | ||
| Designed for use with Thermowell | The thermometer is designed for use with a thermowell. | ||
| Direct Immersion | The thermometer is configured for direct immersion in a solution. | ||
| Explosion Proof | A device that can withstand an explosion of gases within its body and prevent the explosion of gases surrounding it due to sparks, flashes or the explosion of the container itself. The thermometer is also able to maintain an external temperature which will not ignite the surrounding gases. | ||
| Flange fitting | The thermometer has a flange fitting. | ||
| Flexible Capillary | Bulb or sensing element connected to display with a flexible capillary tube. (Liquid/Gas/Vapor types only) | ||
| Vibration Dampening | Needle is dampened, usually with a liquid filling the dial cavity. (For mechanical needles only) | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||