Supplier: Silverson Machines, Inc.
Description: Agglomerate free product, consistent homogeneous product
- Local Interface: Analog Front Panel
- Media Type: Liquids, Solutions, Emulsions, Powders or Granules
- Mix Speed: Continuous Speed
- Mixer Type: Rotor-Stator
-
Supplier: Silverson Machines, Inc.
Description: Eliminate agglomerates and fish eyes, self pump at through put
- Local Interface: Analog Front Panel
- Media Type: Liquids, Solutions, Emulsions, Suspensions, Slurries, Pastes, Colloids, Powders or Granules
- Mix Speed: Continuous Speed
- Mixer Type: Rotor-Stator
-
Supplier: ARDE Barinco, Inc.
Description: with no waste and no agglomerates. The Dispershear evenly incorporates fine powders that can be difficult to disperse with conventional systems. And its one-pass operation won't harm long-chain molecules or other shear-sensitive materials.
- Media Type: Powders or Granules
- Mounting: Benchtop
-
-
Supplier: IKA Works, Inc.
Description: Single Stage homogenizers provide high throughput capabilities and superior mixing results. The IKA HED 2000 is excellent for de-agglomerating, dispersing, emulsifying, blending, disintegrating and homogenizing.
- Application / Industry Use: Agricultural Products, Chemical Processing, Cosmetics Processing, Food and Beverage Processing, Paint / Coating Processing, Paper and Pulp Processing, Pharmaceutical Processing
- Feed Rate: 660 to 15850 GPH
- Media Type: Liquids, Solutions, Emulsions, Suspensions, Slurries, Pastes, Colloids
- Mixer Type: Homogenizer, Rotor-Stator
-
Supplier: Fritsch GmbH - Milling and Sizing
Description: or wet sieving Adjustable oscillation amplitude for easy adaption of the vibration energy to the grinding sample Grinding and sieving in one unit Agglomeration phenomena avoided Ergonomically positioned membrane keyboard IP65, splash-proofed Recyclable
- Capacity: 3.53E-5 to 3.53E-4 cubic feet
- Display Type: Digital Numerical Display
- Media Type: Suspensions, Slurries, Pastes, Colloids, Powders or Granules
- Mounting: Benchtop
-
Supplier: Charles Ross & Son Company
Description: quickly incorporated into the viscous bulk material and agglomerates are dispersed regardless of product flow characteristics. Designs for multiple planetary stirrers and disperser blades are available for more demanding applications. To date, ROSS has supplied over 2,000 of the model PDDM
- Additional Features: Cooling, Heating, Explosion Proof
- Capacity: 0.0668 to 0.5347 cubic feet
- Media Type: Liquids, Solutions, Emulsions
- Media Viscosity: 100000 to 2.00E6 cps
-
Supplier: Dynisco
Description: mixing and can be used in the production of polymer blends or alloys. These blends have been found homogeneous enough to be spun into fibers over the entire range of composition. Since mixing may be independently adjusted, agglomerates of additives, such as fillers or pigments, may be
- Additional Capabilities: Extruder Feed
- Additional Features: Heating, Interchangeable Rotors
- Display Type: Digital Numerical Display
- Local Interface: Analog Front Panel
Find Suppliers by Category Top
More Information Top
-
Development of oxygen selective adsorbents for gas separation and purification
These methods were extended using an LCI Benchtop Granulator to prepare 1 lb of agglomerated IA-3 for extended lifetime studies.
-
Advanced Sorbents as a Versatile Platform for Gas Separation
These methods were extended to larger scale processing using a benchtop extruder and a one pound of agglomerated IA-3 was prepared for extended lifetime studies and hazard testing.
-
Ambient Air Sampling During Quantum-Dot Spray Deposition
Figure 10—Gold quantum-dot agglomerates from overspray collected on filter inside Sono-Tek Exacta- Coat Benchtop system (imaged by Caliber atomic force microscope, tapping method [ORNL Industrial Hygiene Analytical Laboratory]).
-
Design of a High-Throughput Chemical Trace Detection Portal That Samples the Aerodynamic Wake of a Walking Person
This comparison showed that the fluidized-bed aerosol generator was sufficiently de- agglomerating the talc powder, producing an aerosol size distribution that was approximately equal to the wet benchtop measurement [18].
-
Physicochemical characterization of fullerenol and fullerenol synthesis by-products prepared in alkaline media
Aliquots of select fullerenol samples in sealed glass vials (Supplementary information, Figs. SI–S1) were bath sonicated in a Benchtop Ultrasonic EH075CR (Crest, Cleveland, Ohio) to assess the impact … … as several studies have shown that sonication of fullerene agglomerates reduces mean agglomerate size …
-
Nanoscience and Nanotechnology: Environmental and Health Impacts
… easily resuspended once they have been collected into a bulk material because of their propensity to agglomerate . … was based on the study by Maynard et al. (64) who used a benchtop shaking method to …
-
Advanced direct liquefaction concepts for PETC generic units. Quarterly technical progress report, January 1993--March 1993
EXPERIMENTAL Agglomeration of the coal was performed tn a modified 300 mL Parr benchtop stirred .
-
Imaging and analysis of microcalcifications and lipid/necrotic core calcification in fibrous cap atheroma
While we cannot distinguish lCalcs \ 5 lm with our benchtop HR-lCT system, the presence of … … be analyzed using higher resolution imaging modalities, since these very small lCalcs do agglomerate and po- tentially …
-
Engineering of pharmaceutical materials: An industrial perspective
… microscopy has been used at GlaxoSmithKline to observe the crystal size, shape and agglomeration , as well as … shooting on benchtop reactions.6,175,176 .
-
Estimating the effective density of engineered nanomaterials for in vitro dosimetry.
… present a rapid and inexpensive method for accurately measuring the effective density of nano- agglomerates in suspension. This novel method is based on the volume of the pellet obtained by benchtop centrifugation of nanomaterial …