Help with Safety Mats specifications:
Active Safety Area
Back to Top
|
|
| ||
| Length: | The dimensions of the active sensing area of the safety mat. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
| Width: | The dimensions of the active sensing area of the safety mat. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
Performance
Back to Top
|
|
| ||
| Minimum Actuation Force: | The minimum force that must be applied to activate the safety mat. | ||
| Search Logic: | All matching products will have a value less than or equal to the specified value. | ||
| Maximum Mechanical Life: | The maximum number of mechanical activations. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
Switch Pole and Throw Specifications
Back to Top
|
|
| ||
| Switch Pole and Throw Specifications | |||
| Your choices are... | |||
| Single Pole, Single Throw (SPST) | A switch that makes or breaks the connection of a single conductor in a single branch circuit. This switch typically has two terminals. It is commonly referred to as a "Single-Pole" Switch. | ||
| Single Pole, Double Throw (SPDT) | A switch that makes or breaks the connection of a single conductor with either of two other single conductors. This switch typically has 3 terminals, and is commonly used in pairs and called a "Three-Way" switch. | ||
| Double Pole, Single Throw (DPST) | A switch that makes or breaks the connection of two circuit conductors in a single branch circuit. This switch typically has four terminals. | ||
| Double Pole, Double Throw (DPDT) | A switch that makes or breaks the connection of two conductors to two separate circuits. This switch typically has six terminals and is available in both momentary and maintained contact versions. | ||
| Other | Special throw types with more than 2 poles, such as switches designed to split loads into separate circuits (e.g. headlamp switch). | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Switch Configuration | |||
| Your choices are... | |||
| Normally Open (NO) | A switch that when no power is applied the contacts are open. | ||
| Normally Closed (NC) | A switch that when no power is applied the contacts are closed. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Controller Options
Back to Top
|
|
| ||
| External Controller | An external controller is included with the safety mat. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Multi-tasking Controller | Controller can monitor and control more than one safety mat at a time. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
Electrical Switch Specifications
Back to Top
|
|
| ||
| Maximum Current: | The maximum current the mat wiring is rated for. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
| Maximum AC Voltage: | The maximum AC voltage the mat is rated for. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
| Maximum DC Voltage: | The maximum DC voltage the mat is rated for. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
| Maximum Power: | The maximum watts or power the mat is rated for. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
Safety Category Type
Back to Top
|
|
| ||
| Your choices are... | |||
| Type 2 | The safety function shall be checked at machine start up and periodically by the machine control system. If a fault is detected, safe status shall be initiated or if that is not possible, a warning shall be given. The occurrence of a fault between checking functions can lead to a loss of the safety function between checking intervals. | ||
| Type 3 | A single fault in any of the system parts does not lead to a loss of the safety function. Some but not all faults will be detected. An accumulation of undetected faults can lead to a loss of the safety function. | ||
| Type 4 | A single fault does not lead to a loss of the safety function. The faults will be detected in time to prevent the loss of the safety function. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Safety Mat Surface Features
Back to Top
|
|
| ||
| Your choices are... | |||
| Non-skid Surface | Has a slip resistant surface. | ||
| Chemical / Moisture Resistant | |||
| Impact Resistant | |||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Certifications
Back to Top
|
|
| ||
| Your choices are... | |||
| UL | |||
| CE | |||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||