Max/Min or Peak Spike Measurement Digital Multimeters
from RS Components, Ltd.
RS Pro IDM106N RMS Digital Multimeter [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement; Temperature
- Measurement Type: AC; DC
- Form Factor: Handheld
- DC Voltage: 1000
from RS Components, Ltd.
RSCAL(1233236) RSPro IDM106N Multimeter [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement; Temperature
- Measurement Type: AC; DC
- Form Factor: Handheld
- AC Voltage: 1000
from RS Components, Ltd.
UKAS(1233236) RSPro IDM106N Multimeter [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement; Temperature
- Measurement Type: AC; DC
- Form Factor: Handheld
- AC Voltage: 1000
from Seaward Group USA
The CM800 series multimeters are a slim shape design with a hand operated rotary switch and buttons and easy to replace batteries via a battery door. Both the CM800 and CM800R clamp multimeters have an LED backlit display that turns ON/OFF at the touch of a button and the units have an auto power... [See More]
- Special Measurement Types: Audible Continuity; Continuity Check; Max/Min or Peak spike measurement; True RMS Current Measurement
- Measurement Type: AC / DC
- Form Factor: Clamp Meter; Handheld
- Display Digits: 4 Digits
from REED-Direct
4000-count digital display with 40-segment analog bargraph. Audible continuity test and diode check. Peak hold function. Data hold function. DCA zero function. Low battery indication and auto power off. Double molded housing. Electronic overload protection. Designed to meet IEC61010-1 Cat. III 600V. [See More]
- Special Measurement Types: Audible Continuity; Continuity Check; Diode test; Max/Min or Peak spike measurement; True RMS Current Measurement
- Measurement Type: AC / DC
- Form Factor: Clamp Meter; Handheld
- DC Voltage: 0.0 to 600
from Tinsley Precision Instruments
Data logging, data processing, data analysis, data recording, Y(t) recorder XY recorder. Features. Storing Data in Offline /online mode. Transmission of data to PC in Online mode via RS 232 serial interface. Optically isolated transmission from multi meter to adapter. Easy parameter setting manually... [See More]
- Special Measurement Types: Max/Min or Peak spike measurement
- Measurement Type: AC / DC
- Form Factor: Handheld
- Phase: Single Phase
from Sifam Tinsley UK
The Delta series consist of clamp meters and clamp CT ’s. This meter is basically used where the electric current in the conductor can be measured, without having to make physical contact with it. The meter has wide opening jaws with 180o rotational movement which makes it comfortable for the... [See More]
- Special Measurement Types: Diode test; Max/Min or Peak spike measurement; True RMS Current Measurement
- Measurement Type: AC; DC; AC / DC
- Form Factor: Clamp Meter; Handheld
- Display Digits: 4 Digits
from Brighton Electronics, Inc.
IEC1010-1 CSA C22.2 No. 231, ISA-DS82, and UL1244 [See More]
- Special Measurement Types: Continuity Check; Max/Min or Peak spike measurement
- Measurement Type: AC / DC
- Form Factor: Handheld
- Display Digits: 3 Digits; Plus a 1/2 digit
from Hoyt Electrical Instrument Works, Inc.
The Model 2660 CL AC-DC digital clamp tester features a 4000- count LCD along with a full automatic voltage, current, resistor, capacitor measurement, and a frequency counter. It also has a safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals. [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement
- Measurement Type: AC / DC
- Form Factor: Clamp Meter; Handheld
- Display Digits: 4 Digits
from Seaward Group USA
The DM800 series multimeters are a slim shape design with a hand operated rotary switch, buttons and easy to replace batteries via a battery door. Both the DM800 and DM800R are supplied with a protective holster that includes a built-in-tilt stand, a hook hole, and convenient test lead storage. [See More]
- Special Measurement Types: Diode test; Max/Min or Peak spike measurement
- Measurement Type: AC / DC
- Form Factor: Handheld
- Display Digits: 4 Digits
from REED-Direct
Basic 2.5% DC current accuracy. Resolution 0.1A. 4000-count LCD readout. Data Hold. Peak Hold. DC current zero adjust. Auto power off. Complete with test leads, battery and carrying case. SPECIFICATIONS: AC Current Range: 400A, 600A. DC Current Range: 400A, 600A. AC Voltage Range: 400mV to 600V. DC... [See More]
- Special Measurement Types: Max/Min or Peak spike measurement; True RMS Current Measurement
- Measurement Type: AC / DC
- Form Factor: Clamp Meter; Handheld
- DC Voltage: 4 to 600
from Tinsley Precision Instruments
Digital multimeters are suited for universal, general applications in the electrical and electronics radio and television service, training and education. Features. Direct and alternating voltages from 100 μV … 1000V. Direct and alternating currents from 10 μA … 10.00A. [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement; Temp - T/C
- Measurement Type: AC / DC
- Form Factor: Handheld
- Phase: Single Phase
from Sifam Tinsley UK
Gamma 10 It is Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features. • Automatic terminal blocking system (ABS). • Min/Max value storage. • Indication of negative values on the... [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement
- Measurement Type: AC; DC; AC / DC
- Form Factor: Handheld
- Display Digits: 5 Digits
from Hoyt Electrical Instrument Works, Inc.
AC/DC Digital Clamp Meter (Auto Range) [See More]
- Special Measurement Types: Continuity Check; Max/Min or Peak spike measurement
- Measurement Type: AC / DC
- Form Factor: Clamp Meter; Handheld
- Display Digits: 3 Digits; Plus a 1/2 digit
from REED-Direct
Large 3-3/4 (4000-count) LCD. Auto power-off. Continuity Test: 40 ω threshold, beeper at 2.5kHz. Shielded transformer jaws open to 1.2". Max/Min, Data hold. Overload protection. Supplied with batteries. Include test leads and soft carrying case. SPECIFICATIONS: Current Range: 40mA to 100A AC. [See More]
- Special Measurement Types: Audible Continuity; Continuity Check; Max/Min or Peak spike measurement
- Measurement Type: AC
- Form Factor: Clamp Meter; Handheld
- AC Voltage: 0.0 to 400
from Sifam Tinsley UK
Gamma 12 is Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features. • Automatic terminal blocking system (ABS). • Min/Max value storage. • Indication of negative values on the... [See More]
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement
- Measurement Type: AC; DC; AC / DC
- Form Factor: Handheld
- Display Digits: 4 Digits