Supplier: ASME
Description: This standard is no longer an American National Standard or an ASME approved standard as of March 10, 2003. It is available for historical reference only. This Code is applicable to steam turbine generator units of 500 kw and larger and provides: (a) Recommended
-
Supplier: ASME Standards and Certification
Description: This standard is no longer an American National Standard or an ASME approved standard as of March 10, 2003. It is available for historical reference only. This Code is applicable to steam turbine generator units of 500 kw and larger and provides: (a) Recommended
-
Description: This Edition Is Limited to Steam Turbines Intended to Drive Electric Generators of Not Less Than 10,000 Kw Rated Capacity
-
-
Supplier: Nidec Power
Description: Kato Engineering provides custom power generation solutions for a wide range of applications, including: Petroleum, gas & steam turbine, diesel & gas prime mover, power conditioning, traction, government and defense, nuclear power, data centers, and more. For each market
- Applications: Construction, Industrial, Mining, Power
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Other
- Phase: AC Three Phase Power
Find Suppliers by Category Top
Featured Products Top
-
more than 10,000 pounds of steam per hour. ACME Steam Generators are based on more than half a century of accumulated experience in the electric heating field. Easy and economical to install, ACME Steam Generators are available in sizes from 6 KW to 4 MW at all common voltages up to 600 V, 3 PH (read more)
Browse Boilers (industrial) Datasheets for Acme Engineering Products -
multi-stage trim-turbine, designed to fit perfectly into the valve’s body and to maximize energy recovery. LOCPOWER's design allows smart utilities and industries to control pipeline flow and pressure, offering energy harvesting features without sacrificing safety. With LOCPOWER, flow (read more)
Browse Control Valves Datasheets for Bonomi North America, Inc. -
steam generator tubing. INCONEL ® alloy 601 (UNS N06601) Ni 61 Cr 23 C 0.10 Mn 1.0 Al 1.4 Fe Bal S 0.015 Si 0.5 Nickel, higher chromium content for better resistance to oxidizing and reducing environments (read more)
Browse Specialty Nonferrous Metals and Alloys Datasheets for High Performance Alloys, Inc. -
differential pressure sensing technology that is designed with built-in flow conditioning. It achieves an accuracy of +1.0 percent, with a repeatability of +0.1 percent, and operates over a flow range of 10:1. The Wafer-Cone raises the bar for economy, ease of use and performance (read more)
Browse Flow Meters Datasheets for McCrometer, Inc.
More Information Top
-
Thermal test of a hydro-steam turbine in a boiler house
Abstract—The description of the design of GPT-10 reaction-type hydro- steam turbine of 10 - kW capacity is presented.
-
CO2: Separation use, storage
Vapor - KW with counterpressure turbine 10-300 .
-
Renewable energies in Austria
Biomassebefeuerte installations can reach an installed electrical power of some 10 kW (e.g., Stirling motor) up to some 10 MW (e.g., steam turbine ) and possibly also the bottom dreistelligen MW region.
-
Base Load LNG by Cascade Refrigeration
Compression power increases by 7,000-7,500 kw per gas turbine and booster steam turbine train of 73,000 kw thus reducing LNG production by 10 %.
-
The construction goals and spatial layout project of the offshore Three Green Gorges in China
The power generation of 10 thousand kWh by a steam turbine -generator unit of 300 thousand kW , commonly used in China at present, will consume 3.8 tons of standard coal, equal to 5.3 tons of raw coal.
-
CR4 - Thread: Coal: The New Wave Fuel
I dare say, engineered coal could even contribute beautifully towards distributed energy management (coupled with micro steam or gas turbine gen-sets, i.e.: sub 10 kw units), applicable to such as places where main stream/big corp. distributuion network aren't available-this …
-
Steam Turbines: Design, Applications, and Rerating, Second Edition > Shortcut Graphical Methods of Turbine Selection
Base steam rates of single-valve, single-stage steam turbines , 10 in/250 mm exhaust, 2500 hp/1850 kW .
-
Solar pond/fuel assisted water desalination plant
The steam is then allowed to expand in a steam turbine ended by 10 kPa condenser with a net loop output of 70 kW , at the expense of using fuel for 13% of the loop heat input.
-
Conversion of biomass to heat and electricity
… oil/natural gas 5000 kW Boiler1 oil/natural gas 10000 kW Boiler1 biomass 500 kW Boiler1 biomass 5000 kW Steam boiler plant, (oil) 10 MW CHP plant, 10 MWth (biomass combustion, steam turbine 1.5 MWel) SI,min [$/ kW ] 219 108 65 28 …
-
Automatic Generation Control Analysis With Governor Deadband Effects
[ 10 ] Recommended Specification for Speed Governing of Steam Turbines Intended to Drive Electric Generators (500 kW and up), AIEE-ASME Standard No. 600, May 1959.
Indicates content that may require registration and/or purchase.