-
Supplier: DeZURIK, Inc.
Description: distribution, industrial water and wastewater services. The industrial swing check valve design meets or exceeds the current revision of AWWA standard C508. APCO CVS-6000/6000A Valves are available in sizes 2-66” (50-1700mm), can be rated up to 640 psi CWP (4410 kPa) and are available
- Valve Type: Swing Check Valves
-
Supplier: Siemens Energy Sector
Description: The SST-6000 features a barrel-type high-pressure (H) cylinder, an intermediate-pressur e (I) cylinder and up to 3 double flow low-pressure (L) cylinders for 50 and 60 Hz. It is typically operated in conventional steam power plants and enables a power output up to 1200 MW
-
Supplier: Linde North America, Inc.
Description: manufacturing to eliminate the water peak at 1390nm which significantly decreases fiber attenuation in the E band. Linde has high pressure (6000psi) packages specifically designed for this application. Please inquire. Deuterium is a highly flammable and asphyxiant gas. Refer to Linde’s
- Composition: Pure Gas
- Concentration: 100 %
- Product Forms: Gas
- Specialty Gases: Other
-
-
Supplier: SAE International
Description: This SAE Aerospace Information Report (AIR) provides design data reliability information relative to the long-term storage of gas containers or pressure vessels charged with nitrogen or helium at pressures ranging from 6000 to 12 000 psi. The gas containers are cylindrical,
-
Supplier: SAE International
Description: This SAE Aerospace Information Report (AIR) provides design data reliability information relative to the long-term storage of gas containers or pressure vessels charged with nitrogen or helium at pressures ranging from 6000 to 12 000 psi. The gas containers are cylindrical,
-
Supplier: Win Source Electronics
Description: ; AX3FB; ATC-10-3PN; CA3102E14S-1SF80; CA3102R10SL-3SF80; ECCN: EAR99 Fake Threat In the Open Market: 47 pct. MSL Level: Not Applicable REACH Status: REACH Unaffected HTSUS: 8538.90.6000 Mfr: TE Connectivity Deutsch Connectors Other Names: -HD10-3-96P-SI,1734- 1308 Base Product Number:
- Connector Type: Circular / Cylindrical Connector
- Contact Size (AWG): 16 AWG
-
Supplier: Win Source Electronics
Description: -6S; 75-68214-6P; ECCN: EAR99 Fake Threat In the Open Market: 79 pct. MSL Level: Not Applicable REACH Status: REACH Unaffected HTSUS: 8538.90.6000 Mfr: TE Connectivity Deutsch Connectors Other Names: 1734-1310,-HD10-6-12 P-SI Base Product Number: HD10
- Connector Type: Circular / Cylindrical Connector
- Contact Size (AWG): 12 AWG
-
Supplier: HydraCheck Inc.
Description: Ideal for monitoring pump performance and media flows in hydraulic systems. Flows up to 150 GPM (568 Lpm). Pressures up to 6000 PSI (414 bar). Use these flow meters to setup, adjust and test hydraulic pumps, motors, cylinders and more! The only way to test
- Liquid Volumetric Flow Rate: 150 GPM
- End Fittings: Threaded
- Media Temperature Range: -20 to 240 F
- Mounting Type: In-line
-
Supplier: HydraCheck Inc.
Description: – as much as two times the pressure relief valve setting! Flows up to 150 GPM (568 Lpm). Pressures up to 6000 PSI (414 bar). Use these flow meters to setup, adjust and test hydraulic pumps, motors, cylinders, and more! The only way to test a pump and
- Liquid Volumetric Flow Rate: 150 GPM
- End Fittings: Threaded
- Media Temperature Range: -20 to 240 F
- Mounting Type: In-line
-
Supplier: Plasco Inc.
Description: % MOLD SHRINK FLOW: D-955 in/in .005 MOLD SHRINK TRANS: D-955 in/in .007 TENSILE STRENGTH: D-638 psi 6000 TENSILE ELONGATION: D-638 % FLEXURAL STRENGTH: D-790 psi 10500
- Chemical / Polymer System Type: ABS
- Filler Material: Unfilled
- Material Type / Grade: Thermoplastic
- Tensile Modulus: 340 ksi
-
Supplier: Plasco Inc.
Description: % MOLD SHRINK FLOW: D-955 in/in .005 MOLD SHRINK TRANS: D-955 in/in .007 TENSILE STRENGTH: D-638 psi 6000 TENSILE ELONGATION: D-638 % FLEXURAL STRENGTH: D-790 psi
- Chemical / Polymer System Type: ABS
- Filler Material: Unfilled
- Material Type / Grade: Thermoplastic
- Tensile Modulus: 330 ksi
-
Supplier: Plasco Inc.
Description: % MOLD SHRINK FLOW: D-955 in/in .005 MOLD SHRINK TRANS: D-955 in/in .007 TENSILE STRENGTH: D-638 psi 6000 TENSILE ELONGATION: D-638 % FLEXURAL STRENGTH: D-790 psi
- Chemical / Polymer System Type: ABS
- Filler Material: Unfilled
- Material Type / Grade: Thermoplastic
- Tensile Modulus: 340 ksi
-
Supplier: Plasco Inc.
Description: % MOLD SHRINK FLOW: D-955 in/in .005 MOLD SHRINK TRANS: D-955 in/in .007 TENSILE STRENGTH: D-638 psi 6000 TENSILE ELONGATION: D-638 % FLEXURAL STRENGTH: D-790 psi
- Chemical / Polymer System Type: ABS
- Filler Material: Unfilled
- Material Type / Grade: Thermoplastic
- Tensile Modulus: 330 ksi
-
Supplier: HydraCheck Inc.
Description: Ideal for testing in bi-directional applications – hydraulic cylinder testing and hydrostatic transmissions. Flows up to 100 GPM (375 Lpm). Pressures up to 6000 PSI (414 bar). Rugged and Reliable – These meters are constructed with all metal
- Liquid Volumetric Flow Rate: 100 GPM
- End Fittings: Threaded
- Operating Pressure: 6000 psi
- Operating Temperature: -20 to 240 F
-
Supplier: Win Source Electronics
Description: : Industrial Automation Standard Package: 5 Output Type: Analog Current Output: 4 mA ~ 20 mA Accuracy: ±0.25% Pressure Type: Sealed Gauge Operating Pressure: 3000PSI (20684.27kPa) Port Size: Male - 7/16" (11.11mm) UNF Port Style: Threaded Maximum Pressure: 6000PSI
- Operating Temperature: -40 to 125 C
- Package Type / Mounting: Other
- Sensor Grade / Operating Range: Industrial
- Sensor Type: Pressure Sensor
-
Supplier: DeZURIK, Inc.
Description: /150 flanges. Constructed with a heavy cast or ductile iron body. Closure control devices include Air Cushioned Cylinder, Lever & Spring and Lever & Weight. APCO CVS-6000 and CVS-EDV Swing Check Valves are also available. Contact your local DeZURIK representative for a recommendation
- Valve Type: Swing Check Valves
-
Supplier: DeZURIK, Inc.
Description: /150 flanges. They are constructed of NSF epoxy lined and coated 12 mil Dry Film Thickness (DTF) ductile iron bodies and covers. Closure control devices include Air Cushioned Cylinder, Lever & Spring and Lever & Weight. APCO CVS-6000 and CVS-250 Swing Check Valves are also available.
- Valve Type: Swing Check Valves
-
Supplier: Eaton
Description: -strainer is very strong and can readily accommodate the high pressures that are common in this type of service. Pressures up to 6000 psi are not unusual. When steam is being handled, high temperature can be an additional complicating factor. A steam pressure of 1500 psi will
- Applications: General Purpose, Industrial
- Assembly / Element: Strainer Assembly
- Materials of Construction: Monel®, Steel - Carbon / Alloy, Steel - Stainless
- Media: Liquid
-
Supplier: HydraCheck Inc.
Description: meters or portable testers, the HV series loading valve makes testing hydraulic components and circuits on a wide range of agricultural, industrial and mobile equipment fast, efficient and safe. Features: Flow: Up to 210 GPM (800 lpm) Pressure: Up to 6000 PSI (420 bar
- Actuation: Manual / Hand
- Pressure Rating: 6000 psi
- Valve Type: Safety Valves
-
Supplier: Chemac Inc./Uraca/Uhde HPT/Gather/BHDT
Description: ,000 psi) Capacities: 20 to 140 l/hr (5 to 40 gph) Modifier & comonomer injection pumps in low-density polyethylene plants Discharge pressures: 250 to 365 bar (4,000 to 6,000 psi) Capacities: 600 to 3,000 l/hr (160 to 800 gph) Testing pumps for
- Pump Type: Positive Displacement Pumps, Piston / Plunger Pumps
-
Supplier: Chemac Inc./Uraca/Uhde HPT/Gather/BHDT
Description: Thermocouples Test bays designed for pressures up to 6,000 bar (90,000 psi) for pressure/functional testing of High-pressure valves Hydraulic units for High-pressure actuating cylinders Hydraulic bolt tensioners
- Media Description: Air, Water, Gas
-
Supplier: Laurel Electronics LLC
Description: -scale DC voltage ranges from ±200.00 mV with 10 mV resolution to ±600.0V with 100 mV resolution. The 200.00 mV and 2.0000V ranges provide a high input impedance of 1 Gohm to minimize the load on the voltage signal. DC ammeter operation (selected by jumpers) provides four full
- Depth: 143 mm
- Digit or Character Size: 0.37" to 0.56" (9.4mm to 14.2mm)
- Display Technology: LED
- Display Type: Numeric Display
Find Suppliers by Category Top
Featured Products Top
-
). Pressures up to 6000 PSI (414 bar). Use these flow meters to setup, adjust and test hydraulic pumps, motors, cylinders, and more! The only way to test a pump and motors safely and effectively is to use a flow meter. View Specification (read more)
Browse Flow Meters Datasheets for HydraCheck Inc.
More Information Top
-
Processing Ternary Sulfide Ceramics: Powder Preparation, Sintering, and Hot‐Pressing
High-pressure argon was provided from a 41 MPa ( 6000 psi ) cylinder and recycled after the hot isostatic pressing operation using two auxiliary low-pressure cylinders.
-
http://dspace.mit.edu/bitstream/handle/1721.1/75060/1984.12%20Coyner.pdf?sequence=1
Nitrogen gas was chosen because of readily available 6000 psi cylinders .
-
http://dspace.mit.edu/bitstream/handle/1721.1/17593/53277729-MIT.pdf?sequence=2
Before pressure injection, the vacuum pump was removed from the chamber, and a high-pressure Ar gas cylinder ( 6000 psi , BOC Gases) was connected to the inlet valve of the chamber instead.
-
http://dspace.mit.edu/bitstream/handle/1721.1/86542/46921734-MIT.pdf?sequence=2
Before pressure injection, the vacuum pump was removed from the chamber, and a high-pressure Ar gas cylinder ( 6000 psi , BOC Gases) was connected to the inlet valve of the chamber instead.
-
http://calhoun.nps.edu/public/bitstream/handle/10945/4407/09Dec_Ho.pdf?sequence=1
The system is pressurized by a 6000 psi helium cylinder .
-
Pressure affects enzyme function in organic media
Pressurization was performed hyperbarically using N2 from a high-pressure ( 6000 psi ) gas cylinder (Air Products, Inc.).
-
ADVANCED DIAGNOSTIC TECHNIQUES FOR THREE-PHASE SLURRY BUBBLE COLUMN REACTORS(SBCR)
2000 or 6000 psi Gas Cylinder Bank .
-
http://calhoun.nps.edu/public/bitstream/handle/10945/2354/06Sep_Hall_Jason.pdf?sequence=1
The following procedures outline the process for filling the 6000 PSI air cylinder attached to the MAKO 5404BA air compressor and then the process for filling the air cylinders for the AMPHIS testbed.
-
http://dspace.mit.edu/bitstream/handle/1721.1/88890/48911855-MIT.pdf?sequence=2
The gas is supplied from a gas cylinder at 6000 psi to an Advanced SG3611 in-line regulator (see Appendix B.3 for specifications) which is used to control the pressure to the Advance 1 1FRM flowmeter (see Appendix B.4 for …
-
Improved prediction model for time-dependent deformations of concrete: Part 3-Creep at drying
28-day cylinder strength 6000 psi (41.4 N ram-Z).
Indicates content that may require registration and/or purchase.