Supplier: Define Instruments
Description: What it does: Accepts mA input from a flow meter and displays a total. Offers optional relay and analog output for set point alarming and control, plus serial communications. This rate meter and totalizer is ideal for flow rate monitoring of transmitters and sensors with
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: OMEGA Engineering, Inc.
Description: FTB Series totalizers are typically used in applications where accurate measurement of (#2, 4 or 6) heating oil flow is required. The FTB-32 features a fully rotatable, easy-to-read face. The FTB-30 is designed to be mounted horizontally; both the FTB-30 and FTB-31 are shipped complete
- Number of Inputs: 1 inputs
- Number of Control Outputs: 2 outputs
- Display Types: Analog
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse, Switch
-
Supplier: Define Instruments
Description: What it does: Accepts digital pulse inputs from flow sensors and meters. Dual display shows the flow rate and volume. This dual display flow batching totalizer accepts a variety of flow sensor inputs, and has a variety of advanced features, including: flow
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
-
Supplier: OMEGA Engineering, Inc.
Description: The FPM-5750 Battery Operated Flow Indicator and Totalizer is compatible with the following flow sensors: FP-5300, FP-5100, FP-5200 and FP-6000 flow sensors (see related links below). The large digital display indicates flow rate and totalized flow volume
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: 14 to 149 F
- Outputs: Analog Current
-
Supplier: Fluidwell bv
Description: Features Quadrature input to detect the direction of flow. Displays positive and negative flow rate to indicate the flow direction. Total and accumulated total count up and down accoording to the flow direction. Analog and pulse outputs. Displays total and
- Number of Inputs: 2 inputs
- Operating Temperature: -40 to 176 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
- Flow Sensor Inputs: Differential Pressure Meters, True Mass Flow Meters, Velocity Meters
-
Supplier: Fluidwell bv
Description: or total. Flow rate: seven 17mm (0.67") or 8mm (0.31") digits. Total - resettable: seven 17mm (0.67") digits. Accumulated total - not resettable: eleven 8mm (0.31") digits. Separate engineering units for flow rate and total. Selectable on-screen engineering units for flow rate:
- Number of Inputs: 1 inputs
- Operating Temperature: -40 to 158 F
- Outputs: Analog Current, Analog Voltage
- Flow Sensor Inputs: Differential Pressure Meters, True Mass Flow Meters, Velocity Meters
-
Supplier: Define Instruments
Description: What it does: Accepts digital pulse inputs from flow sensors and meters. Displays the flow rate information and in-built totalizers convert the rate into volume. This dual totalizer flow rate controller accepts a wide range of industrial pulse and frequency
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: Fluidwell bv
Description: The F112 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flow meter signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: -40 to 176 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
-
Supplier: Hoffer Flow Controls, Inc.
Description: The Model 2005 is a microprocessor based temperature compensated flow rate indicator/totalizer that provides local display and transmits flow data for control capability. The unit is part of a cost effective family of flow products designed to accept inputs from pulse
- Number of Inputs: 3 inputs
- Number of Control Outputs: 4 outputs
- Operating Temperature: 32 to 158 F
- Outputs: Analog Current, Analog Voltage, Switch
-
Supplier: Clark Solutions
Description: Simultaneous display of rate and total makes the 2-line PD6200 Rate/Totalizer an ideal choice for flow applications. The PD6200 may be configured for a variety of analog input signals, while the PD6300 will take pulse input signals. Via the UV-resistant, NEMA 4X front panel, the
- Analog Input Channels: 1 #
- Operating Temperature: -40 to 149 F
- Outputs: Current Output
- Form Factor: DIN Rail
-
Supplier: Hoffer Flow Controls, Inc.
Description: The Model 2000 is a microprocessor based volumetric flow rate indicator/totalizer that provides local display and transmits flow data for control capability. The unit is part of a cost effective family of flow products designed to accept inputs from pulse producing
- Number of Inputs: 3 inputs
- Number of Control Outputs: 4 outputs
- Operating Temperature: 32 to 158 F
- Outputs: Analog Current, Analog Voltage, Switch
-
Supplier: Fluidwell bv
Description: point linearization of the flow curve - with interpolation. Flow rate monitoring: two alarm values can be set: low and high flow rate alarm. Alarm values can be changed by the operator or they can be password protected. Analog and pulse outputs. Displays total and
- Number of Inputs: 1 inputs
- Operating Temperature: -40 to 176 F
- Features: Alarm, Programmable
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse, Switch
-
Supplier: OMEGA Engineering, Inc.
Description: differential pressure flowmeters, such as orifice plates and pitot tubes. With the DPF66, the user can toggle between rate of flow and total flow (6-digits) from the front panel. The rate display is selectable for units per second, minute, or hour, and the totalizer integrates
- Number of Inputs: 2 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: 41 to 129 F
- Features: Alarm, Controller, Programmable
-
Supplier: Aalborg Instruments
Description: Design Features Displays instantaneous, total and accumulated flow rates. Built-in Flow Linearizer (10 point linearization of the flow curve). Up to 47 different volumetric and mass flow engineering units. Large 13mm (0.51") digits for flow rate and 5.5mm (0.21")
- Control Signal: Analog Voltage, Current Loop, Pulse / Frequency, Serial / Digital
- Interface: Computer Programmable, Digital Front Panel, Ethernet / Networkable
- Type: Current Loop (Transmitter) Input, DC Voltage Input, Serial / Digital Input
- Media: Gas / Air, Liquid
-
Supplier: Clark Solutions
Description: Through significant innovation in technology and design, we developed the Loop Leader® Series of loop-powered rate/totalizers, which are loaded with standard features and built for tough industrial environments. Full Featured Everything comes standard with these meters. The competition may
- Analog Input Channels: 1 #
- Operating Temperature: -4 to 149 F
- Features: DC Current Input, Other Output
- Data Acquisition: Datalogger / Recorder
-
Supplier: OMEGA Engineering, Inc.
Description: Simple Setup DC Powered (DPF143), Loop Powered (DPF144) Remote or Flow Sensor Mounted (with Adaptor) Rugged NEMA 4X (IP67) Plastic Housing Non-Volatile Memory The DPF140 Series of flow meters are micro controller based indicators with transmission and pulse outputs. These units are
- Operating Temperature: -32 to 131 F
-
Supplier: Clark Solutions
Description: coupled to the float and thus, following the float position, indicates the flow rate on a scale. This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts and analog output including
- Media Temperature Range: -292 to 752 F
- Liquid Volumetric Flow Rate: 0.001 to 440 GPM
- Operating Pressure: 4,641.2064 psi
- Operating Temperature: 752 F
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Simple Economical Water Flow Totalizing 1/2" and 3/4" Sizes Rotatable Indicator 8 Digit Registration with 1/10th Gallon Sweep Rugged Bronze Body The KOBOLD WM series is a single jet, dry type, totalizing water meter. It is and ideal choice for a range of sub-metering
- Number of Inputs: 1 inputs
- Display Types: Analog
- Local Interface: Analog Front Panel
- Media Type: Liquid
-
Supplier: Flow Technology, Inc.
Description: correction for K-factor variation, thus improving accuracy. Quick Specs Field mounted rate and total display with linearization. Input Power: Internal Battery, External DC, or 4-20mA Loop Flow Sensor Inputs: Optically isolated pulse or sine wave Display: Simultaneous 8 Digit Totalizer
- Operating Temperature: -4 to 158 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Display Rate or Total Batching Version Available 2 Presets for Rate or Total Fully Scalable Analog or Serial Communications NEMA 4X Front Panel Pulse Input to 10 kHz KOBOLD's MRT series of controllers offers users a full range of frequency input control options. Through use
- Number of Inputs: 3 inputs
- Number of Control Outputs: 3 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Analog Input 0-5 V, 0-10 V, 1-5 V 4-20 mA or 0-20 mA Display Rate, Total, Peak or Valley Completely User Programmable Analog or Serial Communications NEMA 4X Front Panel The KOBOLD INT series of controllers is designed to allow totalization and rate metering with
- Number of Inputs: 2 inputs
- Number of Control Outputs: 3 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
-
Supplier: Hoffer Flow Controls, Inc.
Description: OUTSTANDIING FEATURES HART® Field Communication Protocol 5 Digit Rate, 8 Digit Totalizer LCD display with configurable decimal point location 8 Digit, Non-resettable Grand Total display Pulse Input supports turbine as well as many other pulse generating flowmeters 4-20mA Analog Output
- Operating Temperature: -40 to 158 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: Radwell International
Description: FLOW METER ,1/8 DIN, SAME AS DPF64 OR DPF64A, ANALOG INPUT RATEMETER/TOTALIZER,PROCESS CONTROLLER, FRONT PANEL PROGRAMMING AND SCALING, RATE AND TOTAL IN 1 UNIT, REMOTE OR FRONT PANEL RESET , RELAYS LATCH OR AUTO-RECYCLE, ZERO AND SPAN ADJUSTABLE. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Hoffer Flow Controls, Inc.
Description: Hoffer Flow Controls, Inc. of Elizabeth City, North Carolina proudly introduces the LCD HIT-4U Rate Indicator with Dual Totalizers, Modbus and Data Logging. Featuring a 6-digit rate display and separate 8-digit resettable and non-resettable flow totalizers; the HIT-4U is
- Number of Inputs: 2 inputs
- Operating Temperature: -40 to 176 F
- Outputs: Analog Current, Frequency / Pulse
- Display Types: Digital
-
Supplier: KOBOLD Instruments, Inc.
Description: The DF-ZL electronics convert the frequency signal generated by the rotating vane into a numeric flow reading displayed on the top line of the LCD display, total flow volume since reset on the bottom, and a scalable analog output signal. Two relays with SPDT contacts are
- Media Temperature Range: -10 to 180 F
- Liquid Volumetric Flow Rate: 0.02 to 36 GPM
- Operating Temperature: 0 to 180 F
- Operating Pressure: 145 to 1,450 psi
-
Supplier: ABB Measurement & Analytics
Description: Flow-X series of flow computers is a powerful and versatile automation platform, especially designed for the custody transfer of liquid and gas. It provides different enclosure options for panel-mount and field-mount installation and possesses measurement certifications from multiple,
- Number of Inputs: 4 inputs
- Number of Control Outputs: 4 outputs
- Operating Temperature: 32 to 140 F
- Outputs: Analog Current, Frequency / Pulse
-
Supplier: Badger Meter
Description: output dynamic data in engineering units. These flow processors provide significant improvements in flow meter accuracy under extreme temperature conditions. Provides Total Compensation. Enhances Flow Meter Accuracy. Features a configurable interface software that allows fluid
- Operating Temperature: -40 to 185 F
- Outputs: Analog Voltage, Frequency / Pulse
- Media Type: Liquid
-
Supplier: Bronkhorst USA
Description: Mass Flow Meters/Controllers A CORI-FLOW™ Coriolis Mass Flow Meter / Mass Flow Controller is offered with analog and digital communication, RS-232 with Profibus-DP, Devicenet, Modbus or FLOW-BUS. Applications The instruments are suited for a variety of
- Pipe Diameter: 0 to 0.5 inch
- Mass Flow Rate: 0.18375 to 2.205 lbs/min
- Operating Temperature: 32 to 158 F
- Operating Pressure: 0 to 1,450.377 psi
-
Supplier: Badger Meter
Description: The Cox EC80 Flow Processor is a programmable electronic processor, providing total compensation to enhance flow meter accuracy, while extending the linear flow range. Packaging is provided for remote, direct or embedded mounting to support most installation or application
- Operating Temperature: -40 to 185 F
- Outputs: Analog Voltage, Frequency / Pulse
- Media Type: Liquid
-
Supplier: Panametrics
Description: The PanaFlow XMT1000 is an ultrasonic flow transmitter for liquids that can be installed right at the process measurement point, providing users with an accurate and reliable flow measurement. The XMT1000 is certified for hazardous installations, such as petrochemical and chemical
- Pipe Diameter: 1 to 76 inch
- Velocity Flow Rate: -40.026246719160106 to 40.026246719160106 ft/sec
- Operating Temperature: -40 to 140 F
- Electrical Output: Analog Current, Frequency
-
Supplier: Spirax-Sarco
Description: The M800 gas flow computer receives signals from various pipeline transmitters and converts them to display flowrate, total flow, pressure and temperature. The flow computer operates with Gilflo, ILVA, linear flowmeters, vortex and orifice plates. The M800 can provide density
- Operating Temperature: 32 to 131 F
- Features: Alarm
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
- Display Types: Digital
-
Supplier: Bronkhorst USA
Description: ES-FLOW™ series Low-Flow Ultrasonic Liquid Flow Meters / Controllers General ES-FLOW are Volumetric Liquid Flow Meters/Controllers for very low flowranges. The instruments operate on a innovative measuring principle, usingultrasound in a very small, straight tube.
- Pipe Diameter: 0 to 0.5 inch
- Media Temperature Range: 50 to 185 F
- Liquid Volumetric Flow Rate: 0.001056 to 0.396 GPM
- Operating Pressure: 0 to 928.24128 psi
Find Suppliers by Category Top
Featured Products Top
-
profile has an individual totalizer Sierra Flow Studio Software – Communicate with d·flux in Microsoft Windows environment through Modbus Click to View Specifications (read more)
Browse Gas Flow Meters Datasheets for Sierra Instruments, Inc. -
Controllers? A mass flow controller (MFC) is an instrument used to measure and control the flow rate of gasses. The flow rate is set via an analog or digital command signal. This signal controls a valve which responds by opening or closing depending on the change in flow rate that is required (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
rate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field configurable electronics deliver up to three analog 4-20 mA outputs of five process measurements, including volumetric flow rate, mass flow rate, pressure, temperature and density. Alternate (read more)
Browse Flow Meters Datasheets for Panametrics -
, flow totalization, tank volume calculation, filtering, multiple tare modes, rate-of-change monitoring, and dosing, making them ideal for applications requiring complex measurement and process calculations. Additional details on our website (read more)
Browse Digital Panel Meters Datasheets for Automationdirect.com -
Optional built-in display-mass flow, totalizer, units, set point Human & Systems Interface-local display readout, configure in field Fast Set Point Control- response times as fast as /-80ms Advanced Calibration, NIST-Traceable. Each unit is calibrated over its (read more)
Browse Mass Flow Meters and Controllers Datasheets for Sierra Instruments, Inc. -
. As the rollout of hydrogen as an energy source becomes more widespread, the economy for transporting, storing and trading it as a resource will rapidly and necessarily grow. Accurate flow measurement is therefore crucial in custody transfer. Minor errors can potentially create high financial (read more)
Browse Flow Computers, Totalizers, and Indicators Datasheets for ABB Measurement & Analytics -
oil and gas operations The next evolution in smart remote I/O, the ABB XIO series is an extended range of all-in-one devices to monitor, control and manage oil and gas flow applications. The ABB XIO-08, ABB XIO-04 and ABB XIO (read more)
Browse Flow Computers, Totalizers, and Indicators Datasheets for ABB Measurement & Analytics -
photovoltaic (PV) curves, battery testing, and arbitrary waveforms, supports master-slave parallel operation for scaling up to 64 units (total 1920 kW) with true current sharing via Share bus and Master-Slave bus, offers multiple control interfaces including front-panel HMI with color touchscreen (read more)
Browse Programmable Power Supplies Datasheets for TPS Elektronik GmbH -
intelligence Integrated NHV measurement Reliable across all flow conditions Built in CFD correction Whether you’re upgrading an existing flare measurement system or specifying instrumentation for a new project, the XGF1100 offers a (read more)
Browse Flow Controllers Datasheets for Panametrics -
-fine control • Ultra low hysteresis for consistent, predictable performance • Repeatable positioning enables true "set it and forget it" operation • High flow capacity with precise modulation of inert gases • Fully customizable design to match exact application requirements (read more)
Browse Flow Controllers Datasheets for Clippard
Conduct Research Top
-
Video: Select The Right Mass Flow Controller For Your Application
your application via computer with totalization, batch control, input control, mixing gases, blending gas, and setting alarms. See how SmartTrak 100 was instrumental in a suspended animation experiment by Dr. Kraus, allowing him to achieve his research goals with precise gas flow. When you expect
-
EETimes.com | Electronics Industry News for EEs & Engineering Managers
validated in silicon its ARM926EJ-based SoC platform on UMC's 90-nanometer process. Cadence, SMIC offer analog/mixed-signal reference flow EDA market leader Cadence Design Systems and Chinese foundry Semiconductor Manufacturing International Corp. have jointly developed an analog/mixed-signal reference
-
Battery Fuel Measurement Using Delta-Sigma ADC Devices
remaining (mAH) are calculated by tracking the provides flexible solutions for their application and discharging and charging currents over time. The fuel enables them to manage their battery fuel used is the total discharged current over time and the economically. Since the MCU is used regardless
-
Cloud-Based Apps Transforming Grain Storage
long lasting. IMPROVE OPERATIONAL EFFICIENCY. BY AUTOMATING GRAIN BIN INVENTORY. Combining Cloud-based software applications and adBin Level Data flows from the sensor through a Gateway to the Software. Grain monitoring on phone or PC. 64. COVER STORY. MILLER / july 2021. vanced level sensor
More Information Top
-
ASTM MNL34 - Oil Spill Response Performance Review of Skimmers
During the test the oil distribution rate was monitored by a flow meter with an analog indication and a flow totalizer .
-
Chapter 8-Zero Relative Velocity Skimmers
During the test the oil distribution rate was monitored by a flow meter with an analog indication and a flow totalizer .
-
Flow rate totalizer pulse input two relays analog output from Cole-Parmer
Flow rate totalizer pulse input two relays analog output (Representative photo only .
-
CR4 - Thread: Explosion (or I/S) Proof Flow Totalizer Needed
Can anyone recommend a Flow Totalizer with: - 10 Key Keypad - Analog (or pulse) input from flow meter - Digital Output for Solenoid - Digital Input for Local Estop - Digital Input for Local "Start" HART of Foundation Fieldbus comm to set Set-point and Read …
-
Ultra-clean Fischer-Tropsch (F-T) Fuels Production and Demonstration Project
analog output from jacket water flow meter via ratecounter/ totalizer Volts .
-
Results of Performance Evaluation Testing of Electrical Leak-Detection Methods at the Hanford Mock Tank Site--FY 2002-2003
The Alicat flow controller and the Omega wheel-based flow totalizer were hooked up to the LabView system via pulse analog outputs.
-
AWWA M33 - Flowmeters in Water Supply
• Analog output of instantaneous flow rate through an external integrator and a remote totalizer .
-
ISA IND FLW MEASRMNT - Industrial Flow Measurement
Selection of a digital flowmeter and counter totalization system can improve the overall accuracy of flow totalization by eliminating the approximately 0.5 percent full scale error caused by a typical analog totalizer .
-
AWWA M2 - Instrumentation and Control
In all cases, external electronics convert the frequency signal into a standard analog value proportional to the flow velocity or into a pulse train suitable for input to a totalizer .
-
AWWA M33 - Flowmeters in Water Supply
In all cases, external electronics convert the frequency signal into a standard analog value that is proportional to the flow velocity or a pulse train suitable for input to a totalizer .
Indicates content that may require registration and/or purchase.