-
Supplier: Accuris
Description: Soil improvers and growing media - Extraction of aqua regia soluble elements
-
Supplier: Accuris
Description: Fertilizers - Extraction of total micro-nutrients in fertilizers using aqua regia
-
Supplier: CSA Group
Description: Specifies a method for the extraction, with aqua regia, of trace elements from soils and similar materials containing less than about 20 % (m/m) organic carbon. Materials containing more than about 20 % (m/m) organic carbon will require treatment with additional nitric acid. The
-
-
Description: Specifies a method for the extraction, with aqua regia, of trace elements from soils and similar materials containing less than about 20 % (m/m) organic carbon. Materials containing more than about 20 % (m/m) organic carbon will require treatment with additional nitric acid. The
-
Supplier: Accuris
Description: Sludge, treated biowaste and soil - Digestion of aqua regia soluble fractions of elements
-
Supplier: Accuris
Description: Characterization of sludges - Determination of trace elements and phosphorus - Aqua regia extraction methods
-
Description: ISO 12914:2012 specifies a method for microwave-assisted extraction of elements from samples using aqua regia as the extraction solution for the determination of elements. This method is applicable to all types of soil and soil material.
-
Supplier: CSA Group
Description: ISO 12914:2012 specifies a method for microwave-assisted extraction of elements from samples using aqua regia as the extraction solution for the determination of elements. This method is applicable to all types of soil and soil material.
-
Description: expressed as carbon of less than 5 g/l. The aqua regia digestion method is empirical and it might not release elements completely. However, for most environmental applications, the result is fit for purpose. Aqua regia digestion is suitable for the release of: Ag, Al, As,
-
Supplier: CSA Group
Description: expressed as carbon of less than 5 g/l. The aqua regia digestion method is empirical and it might not release elements completely. However, for most environmental applications, the result is fit for purpose. Aqua regia digestion is suitable for the release of: Ag, Al, As,
-
Supplier: CSA Group
Description: ISO 20280:2007 specifies methods for the determination of arsenic, antimony and selenium, in an aqua regia extract of soil obtained in accordance with ISO 11466, by electrothermal or hydride-generation atomic absorption spectrometry.
-
Description: ISO 20280:2007 specifies methods for the determination of arsenic, antimony and selenium, in an aqua regia extract of soil obtained in accordance with ISO 11466, by electrothermal or hydride-generation atomic absorption spectrometry.
-
Supplier: AENOR
Description: Soil quality. Extraction of trace elements soluble in aqua regia.
-
Supplier: AENOR
Description: Soil improvers and growing media - Determination of aqua regia soluble elements
-
Supplier: AENOR
Description: Fertilizers - Extraction of total micro-nutrients in fertilizers using aqua regia
-
Supplier: AENOR
Description: Organic and organo-mineral fertilizers - Digestion by aqua regia for subsequent determination of elements
-
Supplier: NBK America LLC
Description: Tantalum hex socket head cap screws. Tantalum is a material characterized by excellent chemical resistance and high specific gravity. With excellent corrosion resistance to strong acids such as sulfuric acid, it is also resistant to aqua regia. The specific gravity is approximately
- Length: 0.6299216 inch
- Screw Type: Cap Screw
- Standard Drives: Hex Socket / Allen
- Metric: M6
-
Supplier: Ed Fagan, Inc.
Description: Tantalum is famous for its resistance to corrosion by acids; in fact, below 150˚C, tantalum is almost completely immune to corrosion by aqua regia. Due to its resistance to attack by body fluids, tantalum provides an excellent material for medical devices. Another major use of Tantalum
- Overall Thickness: 0.005 to 0.006 inch
- Tensile Strength (UTS, Break): 75,000 to 250,000 psi
- Specifications: ASTM / ASME
- Type: Alloy, Refractory / Reactive (UNS R)
-
Supplier: ASTM International
Description: laboratory analysis sample can be prepared. 1.3 Three practices are described in this standard: 1.3.1 Practice A -Lithium tetraborate (Li B O ) fusion, 1.3.2 Practice B -Aqua regia dissolution, and 1.3.3 Practice C -Bomb, acid digestion method. 1.4 This standard does not purport to
-
Supplier: ASTM International
Description: ORP measurement include chemical reagents, aqua regia, water, buffer standard salts, phthalate reference buffer solution, phosphate reference buffer solution, chromic acid cleaning solution, detergent, nitric acid, redox standard solution or ferrous-ferric reference solution, and redox
-
Supplier: Jinshiling (Heyuan) Technology Co., Ltd.
Description: aggressive chemicals, including: Concentrated sulfuric acid, hydrofluoric acid, and aqua regia Strong alkalis (e.g., NaOH, KOH) Organic solvents (acetone, DMSO, toluene) Extreme Temperature Stability Maintains mechanical strength across -200°C to +260°C, making it suitable for:
- Chemical System: Fluoropolymer (PTFE / PVDF)
- Features: Other, Thermoset / Crosslinked
-
Supplier: 3X Ceramic Parts Company Limited
Description: most punishing conditions. Made to outperform conventional plastic, metal, carbide-coated, and diffusion alloy materials in corrosive, high-temperature, and high-pressure applications including lime slurries, cat cracker slurries, corrosive acid slurries, high pressure steam, aqua
- Pump Type: Dosing Pumps
-
Supplier: Luma-Metall AB
Description: slowly by acids, aqua regia or alkalis. A mixture of hydrofluoric acid and nitric acid solution dissolve the metal easily already at ordinary temperature. At 400-500 °C, tungsten is oxidized in the air, and at 800 °C this attack is very rapid. The unique characteristics of our fine
- Overall Width / OD: 0.0001574804 to 0.01968505 inch
- Elongation: 1 to 3 %
- Tensile Modulus (E): 59,465.1041364508 ksi
- Applications: Automotive / Vehicular, Electronics / RF-Microwave
Find Suppliers by Category Top
More Information Top
-
VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 6 QUALIFICATION SAMPLE
Table 3-1 Elemental concentrations of Th and U from ICP-AES and ICP-MS analysis of Aqua Regia , DWPF Cold Chem method and Sodium Peroxide/Hydroxide Fusion digestions.
-
VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY'S (DWPF) PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 7A QUALIFICATION SAMPLE
Elemental concentrations of SB7a SRAT Receipt radioactive sludge slun'y obtained from ICP-AES analysis of Aqua Regia , DWPF Cold Chem method and Sodium Peroxide/llydroxide Fusion digestions.
-
VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY'S (DWPF) PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 7B BLEND SAMPLE
Elemental concentrations of SB7b SRAT Receipt radioactive sludge slurry obtained from ICP-AES analysis of Aqua Regia , DWPF Cold Chem method and Sodium Peroxide/Hydroxide Fusion digestions.
-
http://qspace.library.queensu.ca/jspui/bitstream/1974/8104/3/Skeries_Kristina_A_201306_MSC.pdf
Tukey box plots for the percent contribution of each trace element to the summed value, for stream sediments analyzed by ICP-MS/ES and prepared by aqua regia digestion.......99 Figure 3.14.
-
Advanced Chemistry of Rare Elements
most of them dissolve in mineral acids (sonie in aqua regia ) and as such sufficiently electropositive; and they are noted for their variable valencies.
-
Integrated DWPF Melter System (IDMS) campaign report: Hanford Waste Vitrification Plan (HWVP) process demonstration
DissoLution of the sludge in hot aqua regia and subsequent analysis via ICP-AES or ICP-MS has proven to be a somewhat effective means of measuring these.elements.1l This is the method used for these material balances.
-
Compositing and Characterization of Samples from Hanford Tank 241-AY-102/ C-106
57 7.1.2 Hot Aqua Regia Digestion ....................................................................................
-
Chemical Characterization of Metal-Contaminated Soil in Two Study Areas in Finland
The aqua regia extractable and/or concentrated nitric acid leachable median concentrations of selected elements within the study areas were first compared to those from various geochemical baseline studies.
-
Digestion Methods for Total Heavy Metals in Sediments and Soils
Several digestion methods including the aqua regia and different combinations of concentrated acids (HClO4, HNO3, H2SO4, or HF) were compared.
-
Contaminated Urban Soils
Metal extraction method: aqua regia .
Indicates content that may require registration and/or purchase.