Supplier: DOD Technologies Inc.
Description: Titan 2 offers a world-leading solution for the detection of benzene, capable of gas speciation and accurately detecting benzene down to as low as 0.02 ppm (20 ppb) and as high as 20 ppm within a span of 60 seconds. Titan 2 is designed to sample airbourne hazards for the safety
- Operating Temperature: -4 to 122 F
- Features: Audible or Visual Alarms, Intrinsically Safe
- Instrument Type: Detector
- Display: Digital
-
Supplier: Accuris
Description: Automotive fuels - Determination of content of butoxy-benzene in middle distillates - Gas chromatographic method using a flame ionization detector (GC-FID)
-
Supplier: Electro Optical Components, Inc.
Description: Electro Optical Components introduces a series of revolutionary high sensitivity, high performance, low power &, small size gas imaging detector modules. Because they operate at higher temperatures (140K vs 77K) than other cooled MID IR Arrays, they last longer. They can detect more
- Operating Temperature: -40 to 140 F
- Electrical Outputs: Analog Voltage
- Measurement Type: Leakage
- Gas Types: Methane (CH4) / Natural Gas
-
-
Supplier: Accuris
Description: Automotive fuels \x96 Determination of content of butoxy-benzene in middle distillates \x96 Gas chromatographic method using a flame ionization detector (GC-FID)
-
Supplier: Accuris
Description: Draft BS EN 18051 Automotive fuels - Determination of content of butoxy-benzene in middle distillates - Gas chromatographic method using a flame ionization detector (GC-FID)
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of thiophene in refined benzene in the range from 0.80 to 1.80 mg/kg for the Flame Photometric Detector (FPD), and from 0.14 to 2.61 mg/kg for the Pulsed Flame Photometric Detector (PFPD). For the PFPD, the minimum level of
-
Supplier: ASTM International
Description: unless special precautions are taken. 1.3 Non-hydrocarbon gases have a lower detection limit in the concentration range of 0.03 to 100 mole percent using a thermal conductivity detector (TCD) and C1 to C6 hydrocarbons have a lower detection limit in the range of 0.005 to 100 mole percent
-
Supplier: AENOR
Description: Automotive fuels - Determination of content of butoxy-benzene in middle distillates - Gas chromatographic method using a flame ionization detector (GC-FID)
-
Supplier: AENOR
Description: Automotive fuels - Determination of content of butoxy-benzene in middle distillates - Gas chromatographic method using a flame ionization detector (GC-FID)
-
Supplier: Spectrex, Inc.
Description: (H2S), Ammonia (NH3) and aromatic hydrocarbons such as Benzene, Toluene, Xylene, Styrene, etc. with a sensitivity range of 0-500 ppm.m (option: 0-200 ppm.m). Features Proven Flash Type Technology Cost Saving - one system can replace from 5 to 20 point gas detectors Fast Response
-
Supplier: ASTM International
Description: 1.1 This test method is a standard procedure for the determination in percent mass or percent volume of hydrocarbon group types (paraffins, isoparaffins, olefins, naphthenes, aromatics), methanol, ethanol, benzene, toluene, ethylbenzene, xylenes, naphthalene, and methylnaphthalenes in
-
Supplier: ASTM International
Description: capacity of the sorbent used, and by the linear dynamic range of the gas chromatograph, column and detector, or by the sample splitting capability of the analytical instrumentation used. The sorptive capacity is measured as a breakthrough volume of air, which determines the maximum air
Find Suppliers by Category Top
Conduct Research Top
-
Detection of Volatile Organic Compounds (VOC's) with a Spectrally Filtered Cooled Mid-Wave Infrared Camera
The world's petrochemical industry is constantly seeking methods for the detection of Volatile Organic Compounds (VOC's) such as benzene, propane and methane. Leaks of such materials all too often lead to catastrophic equipment damage and loss of life. EPA regulations require reduction
More Information Top
-
BACHARACH Leakator Jr Combustible GasLeak Detector - Combustible Gas Detectors - 4LU63|19-7075 - Grainger Industrial Supply
• Benzene Gas Detectors (4) .
-
TIF Gas Leak Detector Kit - Combustible Gas Detectors - 1TC18|TIF8800A - Grainger Industrial Supply
• Benzene Gas Detectors (4) .
-
Leukemia in benzene workers
Ash RM, Lynch JR (1971): The evaluation of gas detector tube systems: Benzene .
-
Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography
15.1 benzene ; flame photometric detector ; gas chromatog- raphy; thiophene .
-
ASTM MNL3 - Manual on Hydrocarbon Analysis
15.1 benzene ; flame photometric detector ; gas chromatog- raphy; thiophene .
Indicates content that may require registration and/or purchase.