-
Supplier: Accuris
Description: GAGES, LIQUID QUANTITY, CAPACITOR TYPE, INSTALLATION AND CALIBRATION OF
-
Supplier: IET Labs, Inc.
Description: The continuously improving accuracy of capacitor calibrations by NIST brings a better knowledge of capacitance to standards laboratories provided, of course, the laboratories have adequate reference standards. The 1408 Reference Standard Capacitors, with
- Capacitance Range: 0.000009999999999999999 to 0.0001 microF
- Special Features: AC, Component / OEM, DC
- Type: Standard
-
Supplier: ValueTronics International, Inc.
Description: The 16383A is a used Capacitance Standard from Agilent. Engineers use direct current (DC) voltage standards to calibrate, standardize, normalize, and monitor drift, verify linearity, and establish regulation in electronic equipment. Standards are important during electronics
-
-
Supplier: IET Labs, Inc.
Description: This decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference
- Capacitance Range: 0.0001 to 1 microF
- Capacitance Accuracy: 0.05 (+/- %)
- Special Features: AC, Component / OEM, DC, Rack Mount, Stand Alone / Bench
- Type: Capacitance / Capacitor, Decade Box / Substituter
-
Supplier: CSA Group
Description: capacitor or coil arrangements, TEM cells and antenna arrangements in absorber-lined chambers. In the automotive field, these field strength measuring devices are used for measurements specified in the various parts of ISO 11451 and ISO 11452.
-
Description: capacitor or coil arrangements, TEM cells and antenna arrangements in absorber-lined chambers. In the automotive field, these field strength measuring devices are used for measurements specified in the various parts of ISO 11451 and ISO 11452.
-
Supplier: ASTM International
Description: accomplished using a calibration methodology. In the calibration methodology, density and water content are determined by other ASTM Test Standards that measure soil density and water content, thereafter correlating the corresponding measured electrical properties to the soil
-
Supplier: IET Labs, Inc.
Description: The HACS-Z provides a wide range of capacitance in increments as low as 1 pF and a total capacitance of up to 10,000 μF. With its high quality, tight tolerance capacitors, it is an ideal part of a test or calibration system.
- Temperature Coefficient: 20 ±ppm/°C
- Operating Temperature: 10 to 40 C
- Stability: 100 (ppm / year)
- Capacitance Range: 0 to 10,000 microF
-
Supplier: ValueTronics International, Inc.
Description: 105W The Keithley 241 Regulated High Voltage Power Supply is rated 1000 V @ 20 mamps. Applications include calibration of meters, transducers and power supplies and the testing of leakage resistance of insulation, capacitors and diodes. It can also be used as a secondary laboratory
- DC Output Power: 104.99999999999993 watts
- Type: DC Power Supply
-
Description: standard. - 3 Terms and definitions: Added definitions for capacitor switching classes. - 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values. - 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in
-
Supplier: CSA Group
Description: standard. - 3 Terms and definitions: Added definitions for capacitor switching classes. - 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values. - 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in
-
Supplier: CSA Group
Description: electrical values as described in IEC 60444-1 for measurements in transmission mode up to 500 MHz. This fixture includes optional means to add physical load capacitors for the measurement of load resonance parameters up to 30 MHz in accordance with IEC 60444-4. The range of load capacitance
-
Description: electrical values as described in IEC 60444-1 for measurements in transmission mode up to 500 MHz. This fixture includes optional means to add physical load capacitors for the measurement of load resonance parameters up to 30 MHz in accordance with IEC 60444-4. The range of load capacitance
-
Description: system, is to degas samples of oil prepared in the laboratory and containing known concentrations of gases ("gas-in-oil standards") and quantitatively analyse the gases extracted. Two methods of preparing gas-in-oil standards are described. For daily calibration checks of the
-
Supplier: Electro Standards Laboratories
Description: Electro Standards Laboratories – Advanced Systems Design & Services Electro Standards Laboratories (ESL), Cranston, RI, has an extensive track record of technological advancements: state-of-the-art fiber optic switches, complex fiber optic cable assemblies, calibration-quality
- Industry: Aerospace, Automotive, Marine, Telecommunications, Utilities
- Features: North America, Northeast US Only, United States Only
-
Supplier: Electro Standards Laboratories
Description: Electro Standards Laboratories – Advanced Systems Design & Services Electro Standards Laboratories (ESL), Cranston, RI, has an extensive track record of technological advancements: state-of-the-art fiber optic switches, complex fiber optic cable assemblies, calibration-quality
- Industry Served: Aerospace, Automotive, Electrical / Electronics
- Capabilities: Electronic Engineering
- Testing and Forensic Services: Laboratory Testing, Materials Testing
- R&D Services: Modeling, Product Design, Simulation, Software Development, Systems Design
-
Automation Controls Design and Installation Services - Data Network Design and Installation ServicesSupplier: Electro Standards Laboratories
Description: Electro Standards Laboratories – Advanced Systems Design & Services Electro Standards Laboratories (ESL), Cranston, RI, has an extensive track record of technological advancements: state-of-the-art fiber optic switches, complex fiber optic cable assemblies, calibration-quality
- Industry: Aerospace, Consumer, General Industrial, Government, Marine, Military / Law Enforcement
- Services: Design, Model, R&D
- Capabilities: Embedded System Design, Industrial Communication Design, Project Management, System Integration
- Features: North America, Northeast US Only, United States Only
-
Supplier: Electro Standards Laboratories
Description: Electro Standards Laboratories – Advanced Systems Design & Services Electro Standards Laboratories (ESL), Cranston, RI, has an extensive track record of technological advancements: state-of-the-art fiber optic switches, complex fiber optic cable assemblies, calibration-quality
- Cable Types / Application: Aerospace / Military, Computer / Networking, Fiber Optic, Power Cable
- Supplier Capability: Design Assistance, Production Quantities
- Features: North America, Northeast US Only, Other, United States Only
-
Supplier: Microchip Technology, Inc.
Description: TC913A is a monolithic, auto-zeroed operational amplifier. Elimination of the external capacitors allows the designer to increase reliability, lower cost and simplify design by lowering parts count. Since the TC913 is an auto-zeroing op amp, input offset voltage is very low. More important,
-
Supplier: ValueTronics International, Inc.
Description: interface for remote control Three Year Warranty Standard Accessories: User manual, power cord, Kelvin clips (TL 889A), certificate of calibration & test report The BK Precision 891 Bench LCR meter is capable of measuring inductors, capacitors, and resistors at DC or from 20 Hz
-
Supplier: ValueTronics International, Inc.
Description: mains power battery charger as standard equipment for optimized instrument availability and low operating costs DAkkS calibration certificate as standard feature Reduced operating costs for use within ISO 9000 quality systems, documented traceability Applications: The new METRA
Find Suppliers by Category Top
Featured Products Top
-
: P14 W The standard P14-W humidity sensor capacitor is a passive humidity component. The sensor is designed to withstand dew formation and provides extraordinary cross contamination results when applied in (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Innovative Sensor Technology IST USA Division -
In the present time a consecutive phaseout from generally usable, modular, analog standard NIMelectronics to compact single purpose devices utilizing digital signal processing hardware takes place. As example one of the main supliers of nuclear measurement electronics, Mirion Technologies (read more)
Browse Power Supplies Datasheets for Daitron Co., Ltd. -
from 800 MHz to 12.8 GHz. The ADF4378 integrates all necessary power-supply bypass capacitors, which saves board space on compact boards. For multiple data converter and MxFE clock applications, the ADF4378 simplifies clock alignment and calibration routines required with other clock (read more)
Browse RF and Microwave Connectors Datasheets for DigiKey -
. P14-W The standard P14-W humidity sensor capacitor was developed to satisfy applications in HVAC, test & measurement, white goods and in industrial fields and is ideal for use in various application needs where long term durability under extreme conditions are a relevant factor for the (read more)
Browse Humidity Controllers Datasheets for Innovative Sensor Technology IST USA Division -
, and power consumption are important considerations. Supporting Standard SPI, Dual SPI, and Quad SPI operation, the device offers significantly higher read performance than conventional single-I/O serial Flash while retaining a compact eight-pin interface. With a maximum clock frequency of up (read more)
Browse Memory Chips Datasheets for ERSAELECTRONICS PTE. LTD.
More Information Top
-
Evaluation of a Capacitance Scaling System
[7] S. Avramov-Zamurovic, B. Waltrip, A. Koffman, and G. Piper, “ Standard capacitor calibration procedure implemented using control software,” in Proc. Amer. Soc. Eng. Educators Conf., Salt Lake City, UT, Jun. 20–23, 2004.
-
Effect of a magnetic field on the high-frequency dielectric properties of tap water
A change in tan5 changes the Q, while the change in e-K changes the circuit capacitance, since the measuring capacitor is switched by switch S in parallel with a standard calibrated capacitor ; this is done either with unmagnetized water (C1) or…
-
A novel method for the measurement of the C-V characteristic of a solar photovoltaic cell
In order to evaluate the practicality of the proposed technique, a calibrated standard capacitor of value 1.0 μF with negligible leakage resistance was used with different known values of resistances connected in parallel to simulate different RP.
-
Units and standards of electrical measurement. A review of progress
The methods employed for calibrating standard capacitors by reference to the inductance standards are described in another paper by Rayner and Ford.33 For small capacitances, standard air capacitors are employed, and the chief cause of variability in them is atmospheric humidity.
-
Reducing AC impedance measurement errors caused by the DC voltage dependence of broadband high-voltage bias-tees
The AC power of capacitors as calibration standards would help, but a voltage- the VNA was set at PAC = 0 dBm.
-
Study of Standard Mica Capacitors with Respect to Time and Temperature
The standard capacitors are calibrated at a particular fre- quency, voltage and temperature.
-
Workshop on measurement quality assurance for ionizing radiation: Proceedings
Bach electometer and standard capacitor is calibrated usinj Nlsrf-traceable standnrds prior to . installation.
-
Calibration of four-terminal-pair resistor
4TP standard capacitors are calibrated by the network analysis method [3-5].
-
Metrological traceability for AC High-Voltage in Inmetro up to 40 kV
A capacitance and tanδ bridge, with a built-in current comparator, was used in combination with two standard capacitors to calibrate a standard potential transformer (PT), both in ratio and phase angle.
-
Capacitance measurement
Calibration of standard capacitors .
Indicates content that may require registration and/or purchase.