-
Description: Standard measurement and test procedures are established for wide-bandgap semiconductor detectors such as cadmium telluride (CdTe), cadmium-zinc-telluri de (CdZnTe), and mercuric iodide (HgI2) that can be used at room temperature for the detection and quantitative
-
Supplier: First Sensor AG
Description: Alpha, beta, gamma, and X-ray radiation can be detected with silicon PIN photodiodes either directly via the absorption in the crystal lattice or indirectly via the measurement of the luminescence radiation of a scintillation crystal. The Series X from First Sensor features
- Detectable Activity Range: 1 to 10000 KeV
- Detector Output: Count Rate
- Detector Style: Detector Sensing Element Only
- Operating Temperature: -4 to 140 F
-
Supplier: Mirion Technologies
Description: Our organization is comprised of over 1000 talented professionals, passionate about delivering world class products, services, and solutions in the world of radiation detection and protection. From our 13 operating facilities across North America, Europe, and Asia, Mirion Technologies offers
- Area Monitoring: Yes
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
- Types of Radiation Detectors: Ionization Chamber, Scintillation Detector, Semiconductor Diode Detector
-
-
Supplier: Electro Optical Components, Inc.
Description: Custom scintillation detectors assembly can be manufactured upon your request. Different scintillators and tubes can be integrated into gamma scintillation detectors. · NaI(Tl) scintillation detector 1”x1”,2”x2”,3”x3”,4”
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Electro Optical Components, Inc.
Description: A Scintillator Detector is used to measure charged particles and gamma rays. The scintillations produced by these charged particles and gamma rays in a phosphor are detected and amplified by a photomultiplier, giving an electrical output signal.
- Display Options: Digital
- Local Interface: Computer
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Electro Optical Components, Inc.
Description: Detection of radioactive materials Reliable detection of low activities Energy range of gamma radiation: 40 keV – 3 MeV Sensitivity for gamma radiation: 662 keV, typical 2.4 cps/µSv/h Threshold setting range for photon Radiation: 0
- Application Software Included: Yes
- Audio Alarm/Indicator: Yes
- Computer Interface Options: Serial
- Detectable Activity Range: 0.0030 to 40 KeV
-
Supplier: Electro Optical Components, Inc.
Description: HZYH-01 standard handheld gamma spectrometer is mainly used to identify the types and categories of radionuclides in radioactive material on site, to detect and alarm gamma radiation level, and to search and locate radioactive sources. Our spectrometer is mainly aimed at the
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Data Device Corporation (DDC)
Description: DDC’s HSN-3000 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its outputs from the normal high state to a low state with a propagation delay
- Detector Output: Dose Rate
- Detector Style: Detector Sensing Element Only
- Operating Temperature: -67 to 257 F
- Types of Ionizing Radiation Detected: Gamma Ray, Neutron
-
Supplier: Data Device Corporation (DDC)
Description: DDC's HSN-1000 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its output from the normal high state to a low state with a propagation delay
- Detector Output: Dose Rate
- Detector Style: Detector Sensing Element Only
- Operating Temperature: -67 to 257 F
- Types of Ionizing Radiation Detected: Gamma Ray, Neutron
-
Supplier: Landauer, Inc.
Description: LANDAUER dosimeters feature our proprietary OSL dosimetry technology, and can be packaged for occupational radiation monitoring, area radiation monitoring, patient monitoring, emergency response or other services for healthcare.
- Area Monitoring: Yes
- Detector Output: Dose
- Detector Style: Portable Detector
- Personnel Monitoring: Yes
-
Supplier: Sentinel
Description: Portable siren with stand and 25 ft (7.62 m) cable Radiography ranges: 0 to 50 and 0 to 500 mR/hr X-ray ranges: 0 to 5 and 0 to 50 mR/hr 120V AC Dual range area monitor with selectable alarm trip points Two 120V AC remote alarm trip outlets
- Area Monitoring: Yes
- Audio Alarm/Indicator: Yes
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Sentinel
Description: Portable 120V AC hard wired or plug in area monitor Internal detector Non-adjustable trip point set at 2mR/hr Two 5 AMP 120V AC remote alarm outlets
- Area Monitoring: Yes
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
- Local Interface: Analog
-
Supplier: Sentinel
Description: FEATURES Rugged and Reliable Nylon holster or optional see-through holster Removable rubber sleeve for extra protection Water resistant Low power technology (600 hour operation) LCD Screen can be rotated 180o Battery life indicator Large display with backlight Top alarm indication (Can be operated
- Area Monitoring: Yes
- Audio Alarm/Indicator: Yes
- Computer Interface Options: Serial
- Detectable Activity Range: 0.0013 to 45 KeV
-
Supplier: Sentinel
Description: Portable red rotating light with stand, siren, and 25 ft (7.62 m) cable Radiography ranges: 0 to 50 and 0 to 500 mR/hr X-ray ranges: 0 to 5 and 0 to 50 mR/hr 120V AC Dual range area monitor with selectable alarm trip points Two 120V AC remote alarm trip outlet
- Area Monitoring: Yes
- Audio Alarm/Indicator: Yes
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Ultra Energy
Description: Custom built facility from which we design, manufacture, test and support neutron flux detectors.
- Detector Style: Fixed Installation
- Types of Ionizing Radiation Detected: Gamma Ray, X-Ray, Neutron
-
Supplier: LND, Inc.
Description: Thin Wall Beta-gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: Gamma Ionization Chamber
- Operating Temperature: -58 to 212 F
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Ionization Chamber
-
Supplier: LND, Inc.
Description: 200 Cm² Beta- Gamma Proportional Counter
- Operating Temperature: 32 to 122 F
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray
- Types of Radiation Detectors: Proportional Counter
-
Supplier: LND, Inc.
Description: End Window-alpha-beta-ga mma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: Ultra Energy
Description: Low-cost area gamma monitor: single or dual detectors, wide dynamic range (suitable for a variety of applications), detector measurement options, including GM sensors, ionization chambers, and scintillation detectors, Ethernet communications. The CMS Gamma is a new
- Area Monitoring: Yes
- Computer Interface Options: Serial
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Ultra Energy
Description: ANV S2 radiation monitoring system has been developed by Ultra to supply a robust and affordable solution for land and sea applications. The system continuously checks the radiological environment both within the vehicle and external to the platform.
- Area Monitoring: Yes
- Detector Style: Fixed Installation
- Display Options: Digital
- Local Interface: Analog, Digital
-
Supplier: Ultra Energy
Description: CMS Gamma is a compact, mains-powered, continuous monitoring station for measurement of gamma dose rate, providing essential, reliable information to personnel. It is designed for building, area and process monitoring in nuclear facilities.
- Area Monitoring: Yes
- Computer Interface Options: Serial
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Mirion Technologies
Description: Our organization is comprised of over 1000 talented professionals, passionate about delivering world class products, services, and solutions in the world of radiation detection and protection. From our 13 operating facilities across North America, Europe, and Asia, Mirion Technologies offers
- Audio Alarm/Indicator: Yes
- Detectable Activity Range: 0.0150 to 25 KeV
- Detector Output: Count Rate, Dose, Dose Rate
- Detector Style: Fixed Installation, Portable Detector
-
Supplier: Bruker Corporation
Description: The deliberate or accidental release of radioactive material is an increasing threat to modern society. Terrorists fabricating and detonating a dirty bomb with radiological material is a common scenario for emergency services. Radiological material can be easily obtained from medical waste, research
- Area Monitoring: Yes
- Computer Interface Options: Serial
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
Find Suppliers by Category Top
More Information Top
-
Cadmium telluride in tellurium—cadmium films consisting of ultradispersed particles
INTRODUCTION CdTe based semiconductor detectors are now widely used to detect gamma radiation .
-
Soft gamma-ray detector for the ASTRO-H Mission
[18] Takahashi, T., Watanabe, S., and Ishikawa, S., “High-resolution cdte detectors and application to gamma - ray imaging,” Semiconductor Radiation Detection Systems CRC Press, Chapter 8 (2010).
-
Uranium detection using small scintillators in a maritime environment
The authors previously performed a detailed examination of the very low energy gamma - radiations emitted by uranium using room temperature CdZnTe and CdTe semiconductor detectors for detecting small quantities of enriched uranium.3 The low energy portion of the spectrum up …
-
Future of semiconductor gamma-ray spectrometers
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; 440103* --Instrumentation-- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS ; * GAMMA SPECTROMETERS-- SEMICONDUCTOR DETECTORS; *SEMICONDUCTOR DETECTORS; BORON IODIDES; CADMIUM SELENIDES; MERCURY IODIDES; NUCLEAR MEDICINE; TIN SELENIDES .
-
Further evaluations of CdTe as a gamma-ray detector.
N46110* --Instrumentation-- Radiation Detection Instruments-- General Detectors & Monitors; CDTE SEMICONDUCTOR DETECTORS; EFFICIENCY; GAMMA DETECTION .
-
New generation of individual safeguard systems
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; N52100 --Nuclear Materials & Waste Management--Accountability & Safeguards; 440103* --Instrumentation-- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS -- FABRICATION; * GAMMA SPECTROMETERS-- HGI2 SEMICONDUCTOR DETECTORS; *HGI2 SEMICONDUCTOR DETECTORS-- FABRICATION; *SAFEGUARDS; CRYSTAL GROWTH; PERFORMANCE …
-
Development of energy-discriminate CdTe imaging detector for hard x-ray
Cadmium telluride ( CdTe ) semiconductors have been studied for their applications in nuclear radiation detectors , especially for high-energy gamma -ray radiation, because CdTe has good properties for these detectors wide bandgap, high atomic number and good charge transport properties.
-
Super-resolution x-ray imaging by CdTe discrete detector arrays
Cadmium telluride ( CdTe ) semi - conductors have been studied for their applications in nuclear radiation detectors , especially for high-energy gamma -ray radiation, because CdTe has good properties for these detectors wide bandgap, high atomic number and good charge transport properties.
-
Cadmium telluride nuclear radiation detectors
N46130* --Instrumentation-- Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS -- PERFORMANCE; * GAMMA SPECTROMETERS-- CDTE SEMICONDUCTOR DETECTORS; ALUMINIUM; CARRIER MOBILITY; CHLORINE ADDITIONS; CRYSTAL GROWTH; IMPURITIES; POLARIZATION .
-
Defect-induced optical transitions in CdTe and Cd0.96Zn0.04Te
The wide bandgap binary semiconductor CdTe is used as a source material for the preparation of detectors of gamma and X- radiation , as a substrate for fabricating detectors of infrared radiation on the basis of (CdHg)Te and also as a …
Indicates content that may require registration and/or purchase.