Description: Standard measurement and test procedures are established for wide-bandgap semiconductor detectors such as cadmium telluride (CdTe), cadmium-zinc-telluride (CdZnTe), and mercuric iodide (HgI2) that can be used at room temperature for the detection and quantitative
-
Supplier: Electro Optical Components, Inc.
Description: Custom scintillation detectors assembly can be manufactured upon your request. Different scintillators and tubes can be integrated into gamma scintillation detectors. · NaI(Tl) scintillation detector 1”x1”,2”x2”,3”x3”,4”x4”x16” · LaBr3(Ce)/CeBr3 scintillation
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Electro Optical Components, Inc.
Description: CVD diamond is used as a radiation detector for medical and high energy physics applications. Major fields of application include medical dositry, neutron detectors, UV laser systems and X-ray and gamma detection. HIGH purity synthetic CVD Diamond presents unique
- Detectable Activity Range: 5,500 to 1 KeV
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray, Neutron, X-Ray
- Detector Style: Fixed Installation
-
-
Supplier: Micross Components, Inc.
Description: response to gamma radiation. This output can be used to protect electronic components. During gamma radiation, damage to both insulated gate (MOS) and PN junction (bipolar) devices may occur. The effects on electronic components can include, for example, reduction of
- Operating Temperature: -67 to 257 F
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
-
Supplier: Electro Optical Components, Inc.
Description: Detection of radioactive materials Reliable detection of low activities Energy range of gamma radiation: 40 keV – 3 MeV Sensitivity for gamma radiation: 662 keV, typical 2.4 cps/μSv/h Threshold setting range for photon Radiation: 0.15 – 3.60 μSv/h Dose rate range:
- Detectable Activity Range: 40 to 0.003 KeV
- Software: Application Software Included
- Features: Audio Alarm/Indicator
- Computer Interface: Computer
-
Supplier: Electro Optical Components, Inc.
Description: HZYH-01 standard handheld gamma spectrometer is mainly used to identify the types and categories of radionuclides in radioactive material on site, to detect and alarm gamma radiation level, and to search and locate radioactive sources. Our spectrometer is mainly aimed at the
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Landauer, Inc.
Description: LANDAUER dosimeters feature our proprietary OSL dosimetry technology, and can be packaged for occupational radiation monitoring, area radiation monitoring, patient monitoring, emergency response or other services for healthcare.
- Type of Monitoring: Area Monitoring, Personnel Monitoring
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray, X-Ray
- Detector Output: Dose
- Types of Radiation Detectors: Dosimeter
-
Supplier: LND, Inc.
Description: Multi-Window Alpha/Beta/Gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: End Window-alpha-beta-gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: Gamma Detector
- Operating Temperature: -67 to 167 F
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: Pancake Mica Window Alpha-beta-gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: Data Device Corporation (DDC)
Description: DDC’s HSN-3000 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its outputs from the normal high state to a low state with a propagation delay
- Operating Temperature: -67 to 257 F
- Detector Style: Detector Sensing Element Only
- Detector Output: Dose Rate
- Types of Ionizing Radiation Detected: Gamma Ray, Neutron
-
Supplier: First Sensor AG
Description: Alpha, beta, gamma, and X-ray radiation can be detected with silicon PIN photodiodes either directly via the absorption in the crystal lattice or indirectly via the measurement of the luminescence radiation of a scintillation crystal. The Series X from First Sensor features
- Detectable Activity Range: 1 to 10,000 KeV
- Operating Temperature: -4 to 140 F
- Detector Output: Count Rate
- Detector Style: Detector Sensing Element Only
-
Supplier: Sentinel
Description: Die cast aluminum belt worn alarm. Dual range for continuous warning. Alarm output is 100 decibels at 6 inches.
- Features: Audio Alarm/Indicator
- Types of Ionizing Radiation Detected: Gamma Ray
- Type of Monitoring: Personnel Monitoring
- Detector Style: Portable Detector
-
Supplier: Mirion Technologies
Description: radiation detection and instrumentation. Mirion Radiation Monitoring Systems Division - MGP Instruments and MGPI H&B critical state-of-the-art radiation, neutron flux and specific monitoring solutions for nuclear power, fuel processing, laboratories, and accelerators.
- Type of Monitoring: Area Monitoring
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
- Types of Radiation Detectors: Ionization Chamber, Scintillation Detector, Semiconductor Diode Detector
-
Supplier: Sentinel
Description: Rugged, watertight, dustproof radiographic survey meter. Two piece nylon reinforced fiberglass case. Large 3.5 in Mil-Spec meter indicator. Meter face in both mR/hr and uSv/hr. Three Ranges: 0 to 10, 0 to 100 and 0 to1000 mR/hr
- Display Options: Analog
- Type of Monitoring: Area Monitoring
- Detector Output: Dose Rate
- Types of Ionizing Radiation Detected: Gamma Ray, X-Ray
-
Supplier: Sentinel
Description: Portable 120V AC hard wired or plug in area monitor Internal detector Non-adjustable trip point set at 2mR/hr Two 5 AMP 120V AC remote alarm outlets
- Display Options: Analog
- Type of Monitoring: Area Monitoring
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Mirion Technologies
Description: radiation detection and instrumentation. Mirion Dosimetry Services Division - Radiation monitoring services (x-ray badges) and dosimetry solutions for a wide range of applications Radiation monitoring services are the foundation of any radiation safety program. In
- Detectable Activity Range: 25 to 0.015 KeV
- Features: Audio Alarm/Indicator
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray, Neutron, X-Ray
- Detector Output: Count Rate, Dose, Dose Rate
-
Supplier: Sentinel
Description: FEATURES Rugged and Reliable Nylon holster or optional see-through holster Removable rubber sleeve for extra protection Water resistant Low power technology (600 hour operation) LCD Screen can be rotated 180o Battery life indicator Large display with backlight Top alarm indication (Can be operated
- Detectable Activity Range: 45 to 0.0013 KeV
- Type of Monitoring: Area Monitoring, Personnel Monitoring
- Features: Audio Alarm/Indicator, Memory for Data Storage
- Computer Interface: Computer
-
Supplier: Ultra Energy
Description: Wide Measurement Range; Easy to Read Logarithmic Display; Sensitive, Stable Detection; Simple Electronics – Zero Maintenance; Easily Cleaned Stainless Steel Enclosure. The Ultra Electronics HC833 is a self-contained gamma monitoring system for use within shielded areas containing radioactive
- Display Options: Analog, Digital
- Type of Monitoring: Area Monitoring
- Detector Style: Fixed Installation
- Types of Ionizing Radiation Detected: Gamma Ray
-
Supplier: Bruker Corporation
Description: The deliberate or accidental release of radioactive material is an increasing threat to modern society. Terrorists fabricating and detonating a dirty bomb with radiological material is a common scenario for emergency services. Radiological material can be easily obtained from medical waste,
- Type of Monitoring: Area Monitoring
- Computer Interface: Computer
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Ultra Energy
Description: CMS Gamma is a compact, mains-powered, continuous monitoring station for measurement of gamma dose rate, providing essential, reliable information to personnel. It is designed for building, area and process monitoring in nuclear facilities.
- Type of Monitoring: Area Monitoring
- Computer Interface: Computer
- Display Options: Digital
- Detector Output: Dose Rate
-
Supplier: Ultra Energy
Description: ANV S2 radiation monitoring system has been developed by Ultra to supply a robust and affordable solution for land and sea applications. The system continuously checks the radiological environment both within the vehicle and external to the platform.
- Display Options: Analog, Digital
- Type of Monitoring: Area Monitoring
- Detector Style: Fixed Installation
- Types of Ionizing Radiation Detected: Gamma Ray
Find Suppliers by Category Top
More Information Top
-
Cadmium telluride in tellurium—cadmium films consisting of ultradispersed particles
INTRODUCTION CdTe based semiconductor detectors are now widely used to detect gamma radiation .
-
Soft gamma-ray detector for the ASTRO-H Mission
[18] Takahashi, T., Watanabe, S., and Ishikawa, S., “High-resolution cdte detectors and application to gamma - ray imaging,” Semiconductor Radiation Detection Systems CRC Press, Chapter 8 (2010).
-
Uranium detection using small scintillators in a maritime environment
The authors previously performed a detailed examination of the very low energy gamma - radiations emitted by uranium using room temperature CdZnTe and CdTe semiconductor detectors for detecting small quantities of enriched uranium.3 The low energy portion of the spectrum up …
-
Future of semiconductor gamma-ray spectrometers
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; 440103* --Instrumentation-- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS ; * GAMMA SPECTROMETERS-- SEMICONDUCTOR DETECTORS; *SEMICONDUCTOR DETECTORS; BORON IODIDES; CADMIUM SELENIDES; MERCURY IODIDES; NUCLEAR MEDICINE; TIN SELENIDES .
-
Further evaluations of CdTe as a gamma-ray detector.
N46110* --Instrumentation-- Radiation Detection Instruments-- General Detectors & Monitors; CDTE SEMICONDUCTOR DETECTORS; EFFICIENCY; GAMMA DETECTION .
-
New generation of individual safeguard systems
N46130* --Instrumentation--Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; N52100 --Nuclear Materials & Waste Management--Accountability & Safeguards; 440103* --Instrumentation-- Radiation Instrumentation-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS -- FABRICATION; * GAMMA SPECTROMETERS-- HGI2 SEMICONDUCTOR DETECTORS; *HGI2 SEMICONDUCTOR DETECTORS-- FABRICATION; *SAFEGUARDS; CRYSTAL GROWTH; PERFORMANCE …
-
Development of energy-discriminate CdTe imaging detector for hard x-ray
Cadmium telluride ( CdTe ) semiconductors have been studied for their applications in nuclear radiation detectors , especially for high-energy gamma -ray radiation, because CdTe has good properties for these detectors wide bandgap, high atomic number and good charge transport properties.
-
Super-resolution x-ray imaging by CdTe discrete detector arrays
Cadmium telluride ( CdTe ) semi - conductors have been studied for their applications in nuclear radiation detectors , especially for high-energy gamma -ray radiation, because CdTe has good properties for these detectors wide bandgap, high atomic number and good charge transport properties.
-
Cadmium telluride nuclear radiation detectors
N46130* --Instrumentation-- Radiation Detection Instruments-- Nuclear Spectroscopic Instrumentation; * CDTE SEMICONDUCTOR DETECTORS -- PERFORMANCE; * GAMMA SPECTROMETERS-- CDTE SEMICONDUCTOR DETECTORS; ALUMINIUM; CARRIER MOBILITY; CHLORINE ADDITIONS; CRYSTAL GROWTH; IMPURITIES; POLARIZATION .
-
Defect-induced optical transitions in CdTe and Cd0.96Zn0.04Te
The wide bandgap binary semiconductor CdTe is used as a source material for the preparation of detectors of gamma and X- radiation , as a substrate for fabricating detectors of infrared radiation on the basis of (CdHg)Te and also as a …
Indicates content that may require registration and/or purchase.