Supplier: Madison Company
Description: The M8000 miniature liquid level switch has a polypropylene stem and a polypropylene float. Polypropylene is typically suitable for use with acidic liquids such as those found in electroplating and metal cleaning. It is also a great option for lower temperature food operations (up to
- Liquid specific gravity: 0.8000 (Specific Gravity #)
- Material Temperature Range: 221 F
- Maximum Operating Pressure: 100 psi
- Meter Technology: Mechanical / Magnetic Floats
-
Supplier: Madison Company
Description: The M8000-C miniature liquid level switch has a polypropylene stem and a polypropylene float. Polypropylene is typically suitable for use with acidic liquids such as those found in electroplating and metal cleaning. It is also a great option for lower temperature food operations (up to
- Liquid specific gravity: 0.8500 (Specific Gravity #)
- Material Temperature Range: 140 F
- Maximum Operating Pressure: 50 psi
- Meter Technology: Mechanical / Magnetic Floats
-
Supplier: Watson McDaniel Company
Description: Condensate return systems on low pressure steam applications where the condensate temperatures do not exceed 190ºF. As condensate flows into the receiver tank of the pump package from the steam system, the tank fills with water. The float on the
- Discharge Size: 0.5000 inch
- Housing Material: Cast Iron
- Maximum Discharge Pressure: 30 psi
- Maximum Discharge Flow: 6 GPM
-
-
Supplier: Solutions with Innovation, LLC
Description: single entry, the L500E can track changing levels within the tank as well as monitoring liquid interfaces of dissimilar liquids in a single tank like oil water separations, chemical emulsions or condensate levels.
- Configuration (Normal State): Normally Open (NO), Normally Closed (NC)
- Material Temperature Range: -40 to 300 F
- Maximum Operating Pressure: 750 psi
- Media Type: Liquid
-
Supplier: RS Components, Ltd.
Description: condensate tanks, header tanks, storage tanks or for providing an alarm for low levels of lubricating oils or fuels. The mini switch can be side mounted or in an external chamber. The M-Switch has excellent construction and is highly reliable. 25mm
- Maximum Current: 15 amps
- Maximum Operating Pressure: 276 psi
- Pole and Throw Specifications: Single Pole, Double Throw (SPDT)
-
Supplier: RS Components, Ltd.
Description: condensate tanks, header tanks, storage tanks or for providing an alarm for low levels of lubricating oils or fuels. The mini switch can be side mounted or in an external chamber. The M-Switch has excellent construction and is highly reliable. 25mm
- Maximum Operating Pressure: 276 psi
- Pole and Throw Specifications: Single Pole, Double Throw (SPDT)
Find Suppliers by Category Top
Featured Products Top
-
Certified Excellence: Recognized to fulfill the latest UL60335-2-89 requirements, ensuring compliance with ease. Enhanced Safety: Featuring side-mounted float (read more)
Browse Evaporators Datasheets for Backer-Springfield -
supply high wattage suitable for non-low flash point refrigerants. When activated by the float switch, the heating element with a wattage range from 200 watts to 3000 watts will provide the required heat into the application to eliminate condensation water. See the DataSheet (read more)
Browse Evaporators Datasheets for Backer-Springfield -
original electric condensate evaporator pan takes advantage of a traditional style element design that can reliably supply high wattage suitable for non-low flash point refrigerants. When activated by the float switch, the heating element with a wattage range from 200 watts to 3000 watts will provide the required heat into the application to eliminate condensation water. (read more)
Browse Electric Heaters Datasheets for Backer-Springfield -
condensate evaporator pan takes advantage of a traditional style element design that can reliably supply high wattage suitable for non-low flash point refrigerants. When activated by the float switch, the heating element with a wattage range from 200 watts to 3000 watts will provide the required heat into the application to eliminate condensation water. (read more)
Browse Industrial Heaters Datasheets for Backer-Springfield -
element design that can reliably supply high wattage suitable for non-low flash point refrigerants. When activated by the float switch, the heating element with a wattage range from 200 watts to 3000 watts will provide the required heat into the application to eliminate condensation water. (read more)
Browse Immersion Heaters Datasheets for Backer-Springfield -
supply high wattage suitable for non-low flash point refrigerants. When activated by the float switch, the heating element with a wattage range from 200 watts to 3000 watts will provide the required heat into the application to eliminate condensation water. See the DataSheet (read more)
Browse Evaporators Datasheets for Backer-Springfield -
rigorous testing and are UL recognized in the USA and Canada. The original electric condensate evaporator pan takes advantage of a traditional style element design that can reliably supply high wattage suitable for non-low flash point refrigerants. When activated by the float (read more)
Browse Evaporators Datasheets for Backer-Springfield -
. In turn, this shuts down the failed pump, preventing further fluid from escaping. The SPILLSTOP can be equipped with an optional warning alarm whistle, pneumatic-to-electric switch to power warning lights or connect to a SCADA panel, and additional pump shutoff valves for multiple pumps, high suction tank applications, and/or backup pump startup. (read more)
Browse Spill Containment Systems Datasheets for Blacoh Fluid Control, Inc. -
it is now possible to continuously measure even larger filling heights with a single sensor. So far, cascading switches have usually been used for flat non-contact measurements. However, switch solutions on the outer wall of the tank are very complex due to the required cabling and at the same time (read more)
Browse Level Sensors Datasheets for EBE Elektro-Bau-Elemente GmbH -
remove slag and oil; Intelligent control, automatic operation; Easy to install and maintain; The oil separator is equipped with stirring and heating functions to prevent oil from settling in winter; It is equipped with time control switch, which can flexibly (read more)
Browse Oil and Water Separators Datasheets for KINTEP NEW POWER
More Information Top
-
FINAL EVALUATION REPORT-HALLAM NUCLEAR POWER FACILITY. VOLUME II
Level switches and floats in the condensate tanks and steam traps throughout the system operate properly.
-
Building Design and Construction Handbook, Sixth Edition > STEAM-HEATING SYSTEMS
A float switch in the tank starts the pump to return this condensate to the boiler against boiler steam pressure.
-
DESIGN AND FEASIBILITY STUDY OF A PEBBLE BED REACTOR-STEAM POWER PLANT
Condenser hotwell, deaerator, condensate and other storage tanks , and feedwater heaters will be equipped with float switches to actuate annuciator alarms in the event of high or low levels.
Indicates content that may require registration and/or purchase.