Supplier: Baltimore Aircoil Company
Description: FXT Cooling Towers deliver independently verified, fully rated thermal performance over a wide range of flow and temperature requirements. Standard design features satisfy today’s environmental concerns, minimize installation costs, maximize operating reliability, and simplify
- Cooling Capacity: 58 to 257 tons
- Design: Cross Flow, Counter Flow
- Motor Power: 3 to 20 HP
- Operating Weight: 3140 to 9490 lbs
-
Supplier: Baltimore Aircoil Company
Description: Series V Cooling Towers deliver independently verified, fully rated thermal performance over a wide range of flow and temperature requirements. The Low Profile Series V can be installed indoors and can accommodate limited ceiling or enclosure heights compared to other cooling
- Cooling Capacity: 16 to 272 tons
- Design: Cross Flow, Counter Flow
- Motor Power: 1.5 to 40 HP
- Operating Weight: 1620 to 9490 lbs
-
Supplier: Baltimore Aircoil Company
Description: Series 3000 Cooling Towers deliver independently verified, fully rated thermal performance over a wide range of flow and temperature requirements. Standard design features satisfy today’s environmental concerns, minimize installation costs, maximize year-round operating reliability,
- Cooling Capacity: 293 to 1303 tons
- Design: Cross Flow, Counter Flow
- Motor Power: 15 to 100 HP
- Operating Weight: 15170 to 49570 lbs
-
-
Supplier: Baltimore Aircoil Company
Description: Series V Closed Circuit Cooling Towers deliver independently verified, fully rated thermal performance over a wide range of flow and temperature requirements. They can be installed indoors and are as much as 6-1/2 feet lower in overall height than competitive counterflow units, making
- Cooling Capacity: 4 to 108 tons
- Design: Closed Loop
- Motor Power: 1.5 to 40 HP
- Operating Weight: 1875 to 18940 lbs
-
Supplier: U.S. Plastic Corporation
Description: The R400 Series is a high capacity float valve with male NPT inlet and outlet connections. The model features an adjustable short arm for customizing water level. Applications include cooling towers, livestock waterers, car washes, high pressure washes, swimming pools and
- Primary Material of Construction: Brass / Bronze
- Valve Size: 0.7500 inch
- Valve Type: Float Valves
-
Supplier: U.S. Plastic Corporation
Description: The R400 Series is a high capacity float valve with male NPT inlet and outlet connections. The model features an adjustable short arm for customizing water level. Applications include cooling towers, livestock waterers, car washes, high pressure washes, swimming pools and
- Primary Material of Construction: Brass / Bronze
- Valve Type: Float Valves
-
Supplier: U.S. Plastic Corporation
Description: The R400 Series is a high capacity float valve with male NPT inlet and outlet connections. The model features an adjustable short arm for customizing water level. Applications include cooling towers, livestock waterers, car washes, high pressure washes, swimming pools and
- Primary Material of Construction: Brass / Bronze
- Valve Type: Float Valves
-
Supplier: U.S. Plastic Corporation
Description: The R400 Series is a high capacity float valve with male NPT inlet and outlet connections. The model features an adjustable short arm for customizing water level. Applications include cooling towers, livestock waterers, car washes, high pressure washes, swimming pools and
- Primary Material of Construction: Brass / Bronze
- Valve Type: Float Valves
-
Description: . Also, this valve is not affected by water pressure. The remote float ball control valve is widely used for liquid level control in water towers, buildings, waterworks, and other water supply pipeline systems. In brief, we can describe it in three steps, and the
- Valve Type: Directional Valves, Float Valves, Pressure Relief Valves
Find Suppliers by Category Top
Featured Products Top
-
as the primary cooling towers in the power generation industry. Balancing Valves for HVACare used specifically for heating/air conditioning systems in multi (read more)
Browse Plug Valves Datasheets for DeZURIK, Inc. -
Water treatment Generators Cooling towers Condensate lines Evaporators Crude and refined product lines Steam lines Vacuum lines Breakers Metering pumps Hydraulic lines Air or Gas lines (read more)
Browse Check Valves Datasheets for DFT Inc. -
installations with long runs, hills or anywhere there are major changes in elevation. Pump Check Valves are also ideally suited for industrial process systems such as the primary cooling towers in the power generation industry. For more information visit (read more)
Browse Plug Valves Datasheets for DeZURIK, Inc. -
Water & Wastewater Treatment: Industrial: Treating process water, cooling tower water, boiler feed water, wastewater before discharge or reuse (e.g., from manufacturing plants, power plants). Desalination Pretreatment: Removing solids before reverse (read more)
Browse Filter Elements Datasheets for Harbory Filtration -
, natural gas power plants, diesel power backup power, or concentrated solar power (CSP) plants – actuators are needed throughout the plant for effective valve and damper automation. Some typical uses of actuators in this industry include automated control of boiler feedwater, water for cooling (read more)
Browse Electric Rotary Actuators Datasheets for Indelac Controls, Inc.
More Information Top
-
Environmental Report 1998
On July 21, 1998, the Building 812 cooling tower float valve stuck in the open position, with the result that the capacity of the percolation pit was exceeded and the pit overflowed to ground.
-
LEGIONELLOSIS: ENVIRONMENTAL ASPECTS
… of the water reservoir must be maintained to prevent any possibility of a health risk created by back-siphonage from the cooling tower should potable- water pressure drop to or near zero at the water-supply float valve for the cooling tower .
-
Top Operations and Maintenance (O&M) Efficiency Opportunities at DoD/Army Sites - A Guide for O&M/Energy Managers and Practitioners
A float valve within the cooling tower will then allow treated makeup water to enter the system and maintain the given water levels.
-
The eco-friendly management of hotel industry
The ball float valve of the cooling tower must be set in correct level to avoid water drainage.
-
http://www.architects.uga.edu/sites/default/files/pdf/standards/Division%2023%20Heating%20Ventilating%20and%20Air%20Conditioning.pdf
For new cooling towers , provide mechanical float valve (s) on make-up(s) at the tower.
-
MSRE DESIGN AND OPERATIONS REPORT. PART I. DESCRIPTION OF REACTOR DESIGN
1-1/2-in. schd 40 pipe t o provide makeup f o r the cooling tower basin through the float -operated valve , LCV-890.
-
Application of Pulsed Electrical Fields for Advanced Cooling and Water Recovery in Coal-Fired Power Plant
During the fouling test, the artificial water in the reservoir was automatically moved to the reservoir of the cooling tower by gravity via a floating -ball valve , which was installed to control the inflow of make-up water to the cooling tower.
-
City of El Centro geothermal energy utility core field experiment. Final report, February 16, 1979-November 30, 1984
A ball type float valve was to regulate the water level in the cooling tower basin by controlling inflow of makeup water.
-
Power Systems Development Facility. Quarterly report, July 1--September 30, 1996
The float valve that regulates the flow of make up water to the cooling tower basin from the raw water tank continues to malfunction.
Indicates content that may require registration and/or purchase.