Supplier: Accuris
Description: COOLANT FLUID, DIELECTRIC
-
Supplier: Accuris
Description: COOLANT FLUID, HYDROLYTICALLY STABLE, DIELECTRIC
-
Supplier: Accuris
Description: Coolant Fluid, Hydrolytically Stable, Dielectric
-
-
Supplier: Accuris
Description: Dielectric Ethylene Glycol Base Coolant For High Temperature Fuel Cell Coolant Loop \x96 Premix 50/50 DEX-COOL FC
-
Supplier: BP Lubricants North America
Description: points. They flush erosion particles from the work area and provide quick and easy separation in filter systems. BP® Dielectric Fluids provide high metal-removal rates and low electrode wear. BP® Dielectric Fluids possess low odor and fume generation, resist oxidation, and provide
- Type / Function: Dielectric (Transformer / EDM), Metal Working Fluid, Specialty / Other
-
Supplier: Cole-Parmer
Description: • Ideal for transferring hydrocarbons, gasoline, kerosene, heating oils, cutting compounds, and glycol based coolants Applications: Fuels and industrial lubricants—gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants.|Characteristics: Resists
- Maximum Inside Diameter / Size: 0.31102379 inch
- Pressure Rating: 15 psi
- Temperature Range: 165.2 F
- Type: Plastic Tubing
-
Supplier: Cole-Parmer
Description: • Ideal for transferring hydrocarbons, gasoline, kerosene, heating oils, cutting compounds, and glycol based coolants Applications: Fuels and industrial lubricants—gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants.|Characteristics: Resists
- Maximum Inside Diameter / Size: 0.03149608 inch
- Pressure Rating: 40 psi
- Temperature Range: 165.2 F
- Type: Plastic Tubing
-
Supplier: Cole-Parmer
Description: • Ideal for transferring hydrocarbons, gasoline, kerosene, heating oils, cutting compounds, and glycol based coolants Applications: Fuels and industrial lubricants—gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants.|Characteristics: Resists
- Maximum Inside Diameter / Size: 0.25196864 inch
- Pressure Rating: 20 psi
- Temperature Range: 165.2 F
- Type: Plastic Tubing
-
Supplier: Cole-Parmer
Description: • Ideal for transferring hydrocarbons, gasoline, kerosene, heating oils, cutting compounds, and glycol based coolants Applications: Fuels and industrial lubricants—gasoline, kerosene, heating oils, cutting compounds, and glycol-based coolants.|Characteristics: Resists
- Maximum Inside Diameter / Size: 0.18897648 inch
- Pressure Rating: 35 psi
- Temperature Range: 165.2 F
- Type: Plastic Tubing
-
Supplier: Mobil Industrial Lubricants
Description: Mobilgrind Series mineral oils are designed for conventional and high-speed grinding and honing applications across a wide range of materials and operations. They can be used in centralized systems or in individual machine tools. Designed to prevent staining of non-ferrous alloys and copper tubing
- Kinematic Viscosity (@ 40°C): 4 cSt
- Flash Point: 248 F
- Density / Specific Gravity (@15.6°C, 60°F): 0.83 specific gravity
- Type / Function: Dielectric (Transformer / EDM), Grinding Fluid, Lubricant, Metal Forming Fluid, Metal Working Fluid, Specialty / Other
-
Description: applications, especially as dielectric fluids in transformers, capacitors, and coolants.
-
Supplier: 3X Ceramic Parts Company Limited
Description: can be wrapped in 0.05-0.10mm thin brass strip and coated with 400 purpose silicon carbide paste. Coolant: In order to get precision tolerances, a proper amount of coolant should be added to cool the material, such as saponification liquid, kerosene or water. (for example) Workpiece
- Density: 2.4799984348048953 g/cc
- Thermal Conductivity: 1.71 W/m-K
- MOR / Flexural Strength: 15,663.978650577275 psi
- Compressive / Crushing Strength: 73,678.71439345607 psi
-
Supplier: SAE International
Description: conventional TEFC finned housing and rear fan would be replaced by a cylindrical aluminum housing. Special heat transfer oil was chosen as a coolant mainly due to its dielectric property. The liquid cooling housing geometry was defined by series of cooling passages to guide the liquid
-
Supplier: Eaton Cooper Power Systems
Description: completely immersed within a sealed insulating medium. A variety of fluid and gas insulating media are available, including E200 – a fire-resistant, non-toxic, biodegradable, liquid dielectric coolant. FEATURES Optional E200 fluid, the environmentally-preferred switchgear
- Maximum Voltage: 15,000 to 35,000 volts
- Maximum Current: 600 to 1,200 amps
- Features: Other
- Panels: Single-Panel
-
Supplier: Gelest, Inc.
Description: Additional Properties Surface Tension (mN/m) 37.3 Safety Packaging Under Nitrogen Thermal Silicone Fluid High phenyl content fluids are utilized as heat-exchange fluids, dielectric coolants, impregnants for sintered metal bearing, and base oils for high temperature fluids. Low phenyl
- Viscosity: 35 to 40 cP
- Index of Refraction: 1.556
- Chemical System: Silicone
-
Supplier: Hernon Manufacturing, Inc.
Description: unchanged. Typical applications include sealing or unitizing over-molded electrical components against leakage of air, water, coolants, oils and other fluids. As a good insulator, HPS 59801 may also be used to improve the dielectric strength across gaps between high voltage conductors.
- Industry: Aerospace, Automotive, Electrical Power / HV, Electronics, Military / Government (MIL-SPEC / GG), OEM / Industrial
- Features: Impregnating Resin, Specialty / Other
- Cure / Technology: Thermosetting / Crosslinking
-
Supplier: ToneCooling Technology Co., Ltd
Description: easy integration into liquid cooling systems. Supports diverse cooling fluids, such as water, glycol-based mixtures, or dielectric coolants. 6. Efficient Heat Distribution Even heat dissipation across the cooling plate to prevent thermal hotspots. Ensures stable performance of
- Device: Liquid Cooler/Cold Plate
-
Supplier: Eaton Cooper Power Systems
Description: Envirotran™ transformers are the industry’s first transformers to use an edible vegetable oil-based, high-fire-point dielectric coolant. This technological and environmental design breakthrough is the result of years of research and development in dielectric fluids and their use
- Output Type: AC
- Transformer Type: High-Voltage Transformer, Power Transformer, Substation Transformer
- Mounting: Pad-Mounted
- Features: Power / Power System / Distribution Transformer
-
Supplier: ValueTronics International, Inc.
Description: 6) Accessory Pouch User Guide Supply lead for battery charger AC power lead - US Applications: Oil has been used as an insulating medium in transformers for over one hundred years. From the earliest days of transformer design, oil has been recognised as being an efficient coolant with a high
-
Supplier: ToneCooling Technology Co., Ltd
Description: High-quality materials ensure long-term reliability under continuous high-load operation. Supports Liquid Cooling Systems: Compatible with water or dielectric coolant setups for optimal thermal management. Enhanced GPU Lifespan: Maintains safe operating temperatures to reduce wear and
Find Suppliers by Category Top
Featured Products Top
-
Coolant distribution units (CDUs) for data centers: Advanced chip cooling Liquid cooling is an (read more)
Browse Liquid Flow Meters Datasheets for ifm efector inc. -
operating life. • Insulation Resistance: Minimum 1000 Megohms (MΩ) at 1000VDC for high-power circuits; minimum 500 MΩ at 500VDC for signal circuits. This ensures excellent electrical isolation and prevents leakage currents. • Dielectric Strength (Hi (read more)
Browse Slip Rings Datasheets for JiuJiang Ingiant Technology Co., Ltd.
More Information Top
-
Composite-dielectriques All to know on Composites-dielectriques | Techniques of the Ingénieur
In the area of the électronique of power where the essential problem is the evacuation... of the losses, liquids can be used as dielectric refrigerants .
-
Characteristics of liquid dielectrics - general Presentation | Techniques of the Ingénieur
In the area of the électronique of power where the essential problem is the evacuation of losses, liquids can be used as dielectric refrigerants .
-
Dielectrique All to know on Dielectrique | Techniques of the Ingénieur
In the area of the électronique of power where the essential problem is the evacuation... of the losses, liquids can be used as dielectric refrigerants .
-
Natural and synthetic ester dielectric fluids: their relative environmental, fire safety, and electrical performance
Single and three phase prototype field installations using these new dielectric coolants are discussed.
-
Advanced Materials for Thermal Management of Electronic Packaging
Table 10.1 Thermophysical properties of dielectric coolants and water at atmospheric pressure Property .
Indicates content that may require registration and/or purchase.