Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: HORIBA Instruments, Inc.
Description: design of the TITAN T Series is optimized for steady state and transient testing of light and heavy duty gasoline and diesel engines. All systems are equipped with the flexible and powerful combination of SPARC ENGINE test stand controller and STARS ENGINE test automation
- Features: Integrated Data Logger
- Form Factor: Floor Mount
- Online Test Parameters: Power
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 312 Series Portable Flue Gas Analyzer for NOX utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOX found in flue gases or engine exhaust (except
- Application: Continuous Emissions Monitoring, Ambient Air Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Interchangeable Probes, Hazardous Environments, Sampling Pump, Temperature Measurement
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 312 Series Portable Flue Gas Analyzer for NOX utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOX found in flue gases or engine exhaust (except
- Application: Continuous Emissions Monitoring, Ambient Air Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Interchangeable Probes, Sampling Pump, Temperature Measurement
-
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 313 Series Portable Flue Gas Analyzer for NO, NO2, or NOx utilizes reliable, stable NO and/or NO2 sensors which respond quickly to the NO or NO2 present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust (except
- Application: Continuous Emissions Monitoring, Ambient Air Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Sampling Pump
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 313 Series Portable Flue Gas Analyzer for NO, NO2, or NOx utilizes reliable, stable NO and/or NO2 sensors which respond quickly to the NO or NO2 present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust (except
- Application: Continuous Emissions Monitoring, Ambient Air Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Hazardous Environments, Sampling Pump
-
Supplier: McElroy Manufacturing, Inc.
Description: up to 30 percent. Its improved cowling design aids in heat dissipation, and its powerful diesel engine allows it to be used on jobsites where gasoline is not permitted. Like other TracStar iSeries machines, the TracStar 412i is controlled via the DataLogger®, McElroy’s
Find Suppliers by Category Top
Featured Products Top
-
, partially burned fuels, varnish, and lacquers. All of these particles contaminate the oil. Sulfur Oxides (Sox) are common gases with sulfurous fuels (diesel, liquid fuel distillates, heavy fuel oil); Nitrous Oxides (NOx) are more pronounced with Natural gas (CNG, LNG, Propane) fueled engines. Hydrocarbon (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
Backup power is the lifeline of every data center, and its reliability depends on the quality of the diesel fuel stored on-site. Contaminated fuel can clog filters, damage engines, and cause generators to fail when they are needed most—putting uptime, cooling, and compliance at risk (read more)
Browse Filter Elements Datasheets for Kaydon Filtration Corporation -
This white paper reports diesel engine oil analysis data demonstrating use of filtergram particle quantifier x-ray fluorescence (FPQ spectroscopy) to quantify severity of wear and (read more)
Browse X-Ray Fluorescence Spectrometers Datasheets for AMETEK Spectro Scientific -
The HPT604-FW is a compact, high-accuracy sensor that detects water presence, fuel level, and temperature at the samet ime. Ideal for diesel , and other fuel tanks, it offers real-time alarms, reliable data, and excellent performance at a low cost (read more)
Browse Level Sensors Datasheets for Holykell Technology Company Limited -
We had a customer recently request a right angle spiral bevel gear design that was to be incorporated into a hybrid diesel/electrical power package to drive a bus. Much like a train power supply, the diesel engine was to drive a generator that (read more)
Browse Gearboxes and Gearheads Datasheets for DieQua Corporation -
°F (135 °C) under continuous ambient conditions. Featuring stainless steel construction and a selection of wetted seal materials, the EP Series valves are leak-tight, and are suitable for controlling both gases and a wide range of liquids including fuel (gasoline, JP and diesel (read more)
Browse Solenoid Valves Datasheets for Lee Co. (The) -
oscillations, and diesel and single cylinder engine/compressor drives. Additionally, when peak torques are unknown, an MCRT® 88700V reduces the risk of damage from unexpected or accidental torque spikes. About S (read more)
Browse Torque Sensors Datasheets for S. Himmelstein & Company -
meters, a more accurate measurement of total biodiesel and diesel dilution percentage can be obtained. Fuel dilution is one of the biggest problems identified in engine oil analysis. A new ability to make corrections to stored factory fluid data eliminates the need to create new user fluid (read more)
Browse Infrared Spectrometers Datasheets for AMETEK Spectro Scientific
Conduct Research Top
-
Data Logging for Diesel Engine Emissions Control
. This paper will review the data logging requirements for this application, the sensors required and sensor mounting considerations and data logger requirements. Why do these parameters need to be monitored? There are 2 main reasons why it's important to monitor these parameters. First, the engine
-
Exhaust System Monitoring for Diesel Engines
Incoming EPA regulations such as RICE NESHAP have made particulate emissions reduction important in the diesel engine industry. To help manufacturers achieve compliance, CAS DataLoggers has provided a dataTaker DT82I industrial data logger to monitor a new catalytic converter system for values
More Information Top
-
Monitoring Emissions in New York Harbor (.pdf)
To provide continuous monitoring of the diesel engines , each engine is fitted with a dataTaker DT80 data logger ; and where appropriate, a CANgate CANbus to serial gateway.
-
Testing Cooling Systems in Diesel Generators
From CAS DataLoggers Use of a Grant Squirrel 2020 data logger to monitor temperatures at multiple locations in the cooling system of diesel engine drive generators.
-
In-Use Evaluation of Fuel Economy and Emissions from Coal Haul Trucks Using Modified SAE J1321 Procedures and PEMS
These were: 1 Coriolis meters for fuel consumption comparisons 2 Diesel-electric generation system engine speed signal for rpm comparisons 3 Diesel -electric generation system bhp signal for ECM … comparisons Analysts first aligned the ECM and data logger 1-second data, based…
-
Project Startup: Evaluating Coca-Cola's Class 8 Hybrid-Electric Delivery Trucks (Fact Sheet)
The following information will be evaluated during the study to enable comparison of the hybrid and diesel truck fuel economies and operating costs: • Vehicle fueling data from the fuel provider, the engine control module, and data loggers .
-
PEMS Light Duty Vehicles Application: Experiences in downtown Milan
In the first phase, three light duty diesel vehicles, running on their duty cycles (most often in a urban and congested area), were equipped with smart data loggers to retrieve engine and vehicle activity parameters from the engine Electronic Control Unit (ECU…
-
PEMS Light Duty Vehicles Application: Experiences in downtown Milan
In the first phase, three light duty diesel vehicles, running on their duty cycles (most often in a urban and congested area), were equipped with smart data loggers to retrieve engine and vehicle activity parameters from the engine Electronic Control Unit (ECU…
-
Development of Delhi Driving Cycle: A Tool for Realistic Assessment of Exhaust Emissions from Passenger Cars in Delhi
…the speed-time data collection through non-contact type optical speed sensor with real-time data logger , gear position, real-time vehicle position through GPS, engine rpm and recording of on-road fuel consumption data for both diesel as well as gasoline…
-
Exhaust System Monitoring for Diesel Engines
To help manufacturers achieve compliance, CAS DataLoggers has provided a dataTaker DT82I industrial data logger to monitor a new catalytic converter system for values such as … outgoing exhaust temperature, differential pressure in the converter chambers, and the diesel engine 's RPM.
-
Exhaust System Monitoring for Diesel Engines
Additionally, the dataTaker’s alarming capabilities provide a convenient failsafe--if a problem should occur with the data logger in future, alarms have been put in place that … the logger, as well as the operator of the diesel engine , that the engine is…
-
Effectiveness of a Cage Wheel as a Traction Aid
Item Specification Engine Type 4 cylinders, diesel Power 30 kW/2600 rpm Driving type 2 WD with optional front-wheel drive Total weight 18 … torque meter were digitized at a sampling rate of 333.3 samples/s and stored in a data logger .
Indicates content that may require registration and/or purchase.