Supplier: WEH Technologies Inc.
Description: onto the vehicle's receptacle. Full 360° rotation makes for easy engagement with the vehicle's fuel receptacle. Compress the hand grip until locking lever engages and the fueling procedure begins. The natural gas can only flow through the line if there is a safe connection. After
- Maximum Pressure: 3,600 psi
- Orifice Size: 1,417.3236 mil
- Media: Fuel (Liquid)
- Application: Fuel Injection
-
Supplier: Panametrics
Description: display Velocity, volumetric and energy flow rates Totalized flow and trend data Applications: The DF868 liquid flowmeter is a complete ultrasonic flow metering system for measurement of: Water and wastewater Hot / chilled water Water / glycol solutions Refined hydrocarbons
- Pipe Diameter: 0.5 to 300 inch
- Media Temperature Range: -328 to 1,112 F
- Operating Pressure: 0 to 3,000 psi
- Velocity Flow Rate: -40.026246719160106 to 40.026246719160106 ft/sec
-
Supplier: Aggreko
Description: put the energy into the fluid, NOT the atmosphere. Using less fuel than other SuperHeaters, KRAKEN will reduce your carbon footprint. “Dial in” your desired fluid temperature – set it & forget it. Change between fuel types (diesel, propane, natural gas) at the flick of a switch.
- Heating Capacity: 7,327.5 kW
- Heater Type: Air Heater
- Fuel / Energy Source: Diesel / Fuel Oil / Gasoline / Kerosene, Natural Gas / Propane
-
-
Supplier: Spire Metering Technology
Description: generate any disturbance or cause any pressure drop. There is no moving parts to wear out. Model EF10 Flow Cell Flowmeter The best choice if accuracy is of crucial importance. Its transducer is a flow-cell (or spool-piece), where a pair of ultrasonic sensors have already been built in.
- Velocity Flow Rate: -32 to 32 ft/sec
- Operating Temperature: 140 F
- Features: Aggressive / Corrosive Process Media, Audible or Visual Alarms, Liquid, Recorder / Totalizer Functions, Velocity Meter
- Electrical Output: Analog Current, Switch
-
Supplier: Panametrics
Description: The TransPort PT900 portable ultrasonic liquid flow meter is Panametrics’ newest portable clamp-on flow meter. It easily attaches to the piping fixture to measure flow within the pipe. Users have no need to cut into the pipe and cause delays and downtime. The PT900 can also be
- Pipe Diameter: 0.5 to 300 inch
- Media Temperature Range: -328 to 752 F
- Velocity Flow Rate: 0.0984251968503937 to 39.993438320209975 ft/sec
- Operating Temperature: -4 to 131 F
-
Supplier: Higher Power Supplies, Inc.
Description: powder coated steel frame • Super efficient schedule 80 coil with one-piece molded insulation combustion chamber • Stainless steel coil wrap • Adjustable thermostat temperature control • Safety pressure relief valve • 9 gallon poly diesel fuel tank with fuel filter • In-line
- Water Jet Pressure: 4,000 psi
- Water Flow: 360 GPH
- Operation: Cleaning / Surface Preparation
- Power Source: Electric Motor
-
Supplier: Higher Power Supplies, Inc.
Description: powder coated steel frame • Super efficient schedule 80 coil with one-piece molded insulation combustion chamber • Stainless steel coil wrap • Adjustable thermostat temperature control • Safety pressure relief valve • 9 gallon poly diesel fuel tank with fuel filter • In-line
- Water Jet Pressure: 4,000 psi
- Water Flow: 180 GPH
- Operation: Cleaning / Surface Preparation
- Power Source: Electric Motor
-
Supplier: Higher Power Supplies, Inc.
Description: powder coated steel frame • Super efficient schedule 80 coil with one-piece molded insulation combustion chamber • Stainless steel coil wrap • Approximate Heat Rise 110° F • Adjustable thermostat temperature control • Safety pressure relief valve • 9 gallon poly diesel fuel tank with
- Water Jet Pressure: 4,000 psi
- Water Flow: 240 GPH
- Operation: Cleaning / Surface Preparation
- Power Source: Electric Motor
-
Supplier: Higher Power Supplies, Inc.
Description: powder coated steel frame • Super efficient schedule 80 coil with one-piece molded insulation combustion chamber • Stainless steel coil wrap • Adjustable thermostat temperature control • Safety pressure relief valve • 9 gallon poly diesel fuel tank with fuel filter • Approximate
- Water Jet Pressure: 4,000 psi
- Water Flow: 240 GPH
- Operation: Cleaning / Surface Preparation
- Power Source: Electric Motor
-
Supplier: Weiss Technik North America, Inc.
Description: Pumping fuel out of the vehicle Emptying system The fuel can be cooled and heated. The controller for the fuel is situated directly in front of the petrol-filling pistol (outlet of the fuel line). In front of the discharge nozzle is an additional digital volume
- Temperature Control: Cooling, Heating
- Features: Windows
-
Supplier: Reverso Pumps, Inc.
Description: Description: Self-priming vane pump that can be used for transferring medium viscosity oils and diesel fuel. Usually ships within one business day. 110V, 60 Hz and On/off Switch (80-2999), 1 left Features Specifications Options Spare Parts Related Products For medium viscosity oils and
- Maximum Discharge Flow: 7 GPM
- Pump Type: Positive Displacement Pumps, Rotary Vane Pumps
-
Supplier: Spire Metering Technology
Description: generate any disturbance or cause any pressure drop. There is no moving parts to wear out. Model EF10 Flow Cell Flowmeter The best choice if accuracy is of crucial importance. Its transducer is a flow-cell (or spool-piece), where a pair of ultrasonic sensors have already been built in.
- Velocity Flow Rate: -32 to 32 ft/sec
- Operating Temperature: 140 F
- Features: Aggressive / Corrosive Process Media, Audible or Visual Alarms, Liquid, Recorder / Totalizer Functions, Velocity Meter
- Electrical Output: Analog Current, Switch
-
Supplier: Spire Metering Technology
Description: generate any disturbance or cause any pressure drop. There is no moving parts to wear out. Model EF10 Flow Cell Flowmeter The best choice if accuracy is of crucial importance. Its transducer is a flow-cell (or spool-piece), where a pair of ultrasonic sensors have already been built in.
- Velocity Flow Rate: -32 to 32 ft/sec
- Operating Temperature: 140 F
- Features: Aggressive / Corrosive Process Media, Audible or Visual Alarms, Liquid, Recorder / Totalizer Functions, Velocity Meter
- Electrical Output: Analog Current, Switch
-
Supplier: Reverso Pumps, Inc.
Description: Description: Self-priming vane pump that can be used for diesel fuel only. Usually ships within one business day. FITTINGS SHOWN ARE NOT INCLUDED. Ports are 1" Female BSPP. Features Specifications Options Spare Parts Related Products For diesel only Self-priming Self-ventilated
- Pump Type: Positive Displacement Pumps, Rotary Vane Pumps, Self-Priming Pump
-
Supplier: Westerbeke Corporation
Description: remote starting capability Easy-to-read operator’s manual and parts list Emergency stop switch Steel mounting skid Electronic governor (Optional) User-friendly trouble-free controls Optimum vibration isolation Engine Features Low maintenance costs Low fuel consumption Self-bleeding
- Wattage: 8,000 watts
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: capability Easy-to-read operator’s manual and parts list Emergency stop switch Steel mounting skid Electronic governor (standard) User-friendly trouble-free controls Optimum vibration isolation Engine Features Low maintenance costs Low fuel consumption Self-bleeding fuel system Easy
- Wattage: 8,900 watts
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: consumption Self-bleeding fuel system Easy one-side servicing Water-cooled cast iron block for a longer life Cooling designed for high ambient temperatures 12 volt starter motor 12 volt 50 ampere alternator Electric fuel pump Safety shutdowns: High water temperature, Low oil pressure
- Wattage: 14,000 watts
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
- Applications: Industrial
-
Supplier: Westerbeke Corporation
Description: Easy-to-read operator’s manual and parts list Emergency stop switch Steel mounting skid Electronic governor (Optional) User-friendly trouble-free controls Optimum vibration isolation Engine Features Low maintenance costs Low fuel consumption Self-bleeding fuel system Easy one-side
- Wattage: 5,700 watts
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
- Applications: Industrial
-
Supplier: Caterpillar Oil & Gas
Description: stainless steel wire seal Four turbochargers with watercooled bearings (center mounted) Exhaust outlet, dual 203 mm (8 in) round flange Flywheel and Flywheel Housings Flywheel, SAE No. 0, 151 teeth Flywheel housing, SAE No. 0 Fuel System Primary fuel filter Fuel priming pump
- Horse Power: 2,250 to 2,500 HP
- Displacement: 0.9651972957012854 liters
- Length: 113.8 inch
- Width: 64.2 inch
-
Supplier: Airmar Technology Corporation
Description: sensors to report, alert and filter data through user programmed parameters. Diesel Flow Meter data via SmartBoat’s exclusive single and dual chamber (differential) models. These CAN based DFM sensors are easily connected to the ASM and configured using SmartFlex View. Fuel
- Features: Serial Data Converter, Serial Hub
-
Supplier: SAE International
Description: Stricter regulatory standards are continuously adopted worldwide to control heavy duty emissions, and at the same time, fuel economy requirements have significantly lowered exhaust temperatures. The net result is a significant increase in Precious Group Metal (PGM) usage with current
Find Suppliers by Category Top
Featured Products Top
-
The fuel flow meter provides accurate and reliable measurement of fuel consumption for diesel and gasoline systems. It helps optimize fuel efficiency, reduce operating costs, and ensure stable performance in vehicles, generators, and industrial fuel monitoring applications (read more)
Browse Flow Meters Datasheets for Holykell Technology Company Limited -
readings across wide temperature ranges without drifting. Resistant to adhesion, buildup, and foam interference, ideal for gasoline, diesel, kerosene, water, saline solution, chemical liquids, lubricating oil and other liquids. Robust full-metal housing, durable against drops (read more)
Browse Level Sensors Datasheets for Holykell Technology Company Limited -
prevent microbial growth in stored diesel Prevent premature degradation of stored diesel Accommodate green fuel products such as Hydrotreated Vegetable Oil (HVO) and Biodiesel blends Mitigate contamination resulting from storage tank agitation Exceed the most (read more)
Browse Filtration Equipment Datasheets for Kaydon Filtration Corporation -
The HPT604-FW is a compact, high-accuracy sensor that detects water presence, fuel level, and temperature at the samet ime. Ideal for diesel , and other fuel tanks, it offers real-time alarms, reliable data, and excellent performance at a low cost (read more)
Browse Level Sensors Datasheets for Holykell Technology Company Limited -
Industrial Precision Flow Meters for Hydraulics, Fuel Transfer & Dosing High-Precision flow measurement for demanding industrial applications (read more)
Browse Liquid Handling Pumps Datasheets for jbj Techniques Limited -
Model OF is the oval-gear flow sensor that is compact and does not require any straight pipe length so that it can be easily built in the machines and systems. Fluids including fuels such as kerosene and heavy oil can be measured. Due to its excellent repeatability, it has merits (read more)
Browse Flow Meters Datasheets for Aichi Tokei Denki Co., Ltd. -
five process variables (mass flow, volumetric flow, temperature, pressure, and density). It relies on true physical calculations from advanced 3D polynomial data tables to deliver the flow data you rely on. These diagnostics make switching gases faster and easier, with absolutely no loss in accuracy (read more)
Browse Gas Flow Meters Datasheets for Sierra Instruments, Inc. -
Common Applications Adhesives Heating Chemical Component Heating Diesel Fuel Heating in cold weather (read more)
Browse Drum Heaters Datasheets for Tempco Electric Heater Corporation -
and VAE series valves for superior performance. Choose valves made by DynaQuip, the proven manufacturer that has been setting the standard for decades. Applications for VME, VLE, VAE, VHC, Series Valves • For use as fuel line shutoffs for gasoline and diesel (read more)
Browse Industrial Valves Datasheets for DynaQuip Controls -
before filling or application. Crucial for spray application quality. Oil & Petrochemical Industry: Fuels: Filtering diesel, gasoline, kerosene, jet fuel, biodiesel (both feedstocks and finished fuel). Lubricants: Filtering base oils and (read more)
Browse Filter Elements Datasheets for Harbory Filtration
More Information Top
-
Self‐sustained reformation of diesel fuel using a SiC block with penetrating walls
At this moment the diesel spray was switched on—the fuel and air flow rates about 6 ml/min, and 20 l/min, respectively.
-
Modulation in comprehensive two-dimensional gas chromatography: 20 years of innovation
The authors successfully used the flow - switching system to analyse a mixture of VOCs, diesel fuel and aromatics in gasoline [74, 77].
-
Comprehensive two dimensional gas chromatography review
The use of flow - switching GC6GC to analyze complex hydrocarbon mixtures such as diesel fuel , motor oil, and petroleum-contaminated environmental samples was demonstrated by Seeley et al. [118].
-
Multi-Fuel Fuel Processor and PEM Fuel Cell System for Vehicles
Without stopping, the fuel supply was switched to diesel fuel and, after a brief dip in reformate flow , the power returned to 5.3 kWe in under 10 seconds.
-
Ultra-Clean Transient Operation of a Compression Ignition Engine Fuelled with Upgraded Hydrous Bioethanol
As highlighted in Table 1, the fuel volume flow to be injected in the cylinder doubles when switching from fossil Diesel to OBATE™ fuel.
-
Federal Register > Wednesday, December 27, 2006 > [71 FR 77872] Fuel Economy Labeling of Motor Vehicles: Revisions To Improve Calculation of Fuel Economy Estim...
…128 seconds (i.e., at 130 seconds), simultaneously switch the sample flows from the "US06 City" bags and samples to the "US06 Highway" bags and samples, switch gas flow measuring device No. 1 (and the petroleum- fueled diesel hydrocarbon integrator No. 1…
-
Code of Federal Regulations > Title 40 - Protection of Environment > Clean Air Act / Air Programs (CAA) > [40 CFR Part 86] Control of Emissions from New and in...
…128 seconds (i.e., at 130 seconds), simultaneously switch the sample flows from the “US06 City” bags and samples to the “US06 Highway” bags and samples, switch gas flow measuring device No. 1 (and the petroleum- fueled diesel hydrocarbon integrator No. 1…
-
Federal Register > Thursday, December 1, 2011 > [76 FR 74854] 2017 and Later Model Year Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel ...
…to occur at 594 seconds, simultaneously switch the sample flows from the SC03 bags and samples to the "HFET" bags and samples, switch off gas flow measuring device No. 1, switch off the No. 1 petroleum- fueled diesel hydrocarbon integrator, mark the…
-
Trade-off between NOX, Soot and EGR rates for
an IDI diesel engine fuelled with JB5
…supply system was connected in two fuel tanks, one for diesel fuel and another for JB5, two control valves which allowed rapid switching between the diesel oil used as a … and the test alternative fuel , and fuel flow detector Ono Sokki model…
-
DUIT: Distributed Utility Integration Test
…switching; load banks • Ability to test in both radial and network circuit configurations • Grid supply – voltage, megavolt amperes, switching arrangements, and limitations • Fuel supply and storage – … line size, pressure, and flow rate; diesel , hydrogen, gasoline, and liquefied…
Indicates content that may require registration and/or purchase.