-
Supplier: Accuris
Description: Connectors for electronic equipment - Part 7-51: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 500 MHz (IEC 48B/1694/CD:2006)
-
Resistive Temperature Devices (RTD) Elements - Thin Film DIN Class B Elements -- 5 Pack RTD ElementsSupplier: OMEGA Engineering, Inc.
Description: OMEGA thin film DIN Class "B" RTD elements have a resistance tolerance of 100.00 0.12, 500.00 0.60, or 1000.00 1.20 at 0C, and they meet the requirements of IEC751. They are sold with 0.2 mm diameter by 10 mm long gold palladium leads. Series WS elements have a donut shape that
- Length: 0.0906 to 0.3740 inch
- Nominal Resistance: 100 to 1000 R0 @ 0° C
- Operating Temperature: -94 to 932 F
- Sensor Technology: Thin Film
-
Supplier: Cole-Parmer
Description: • Ideal for critical process control and heat treating applications • Time Constant: 3 seconds or greater • Custom designs or changes to this product are available upon request Alpha coefficient is 0.003850 omega/omega/°C (DIN IEC 751). Resistance at ice
- Basic Element Used: RTD
-
-
Supplier: Gefran
Description: Temperature limits: - 200 ... +800°C Tolerance: UNI 7937, IEC 751 standards: ± 0.15°C at 0°C for class A (1/2 DIN) ± 0.30°C at 0°C for class B (1 DIN) ± 0.10°C at 0°C for 1/3 DIN class Insulation: > 100 MOhm for voltage values from 10 to 100 Vcc PT100 wire-wound
- Element Material: Platinum
- Reference Resistance: 100 Ohms (Most Common)
-
Supplier: Gefran
Description: Temperature limits: -200 ... +600°C Tolerance: UNI 7937, IEC 751 standards: ± 0.15°C at 0°C for class A (1/2 DIN) ± 0.30°C at 0°C for class B (1 DIN) ± 0.10°C at 0°C for 1/3 DIN class Insulation: Mineral Oxide (MgO) PT100 wire-wound resistance thermometer Min.
- Element Material: Platinum
- Reference Resistance: 100 Ohms (Most Common)
-
Supplier: Gefran
Description: Temperature Limits: -200 ... +600° C Tolerance: UNI 7937, IEC 751 standards: ± 0.15° C a 0° C for class A (1/2 DIN) ± 0.30° C a 0° C for class B (1 DIN) ± 0.10° C a 0° C for 1/3 DIN class Compact mineral insulated (MgO) resistance thermometer element (Pt100 at 0°C)
- # of Lead Wires Per Element: 2, 3, 4
- Diameter or Width Range: 0.1181 to 0.2362 inch
- Element Configuration: Single Element, Double Element
- Element Material: Platinum
-
Supplier: Gefran
Description: Temperature limits: - 40 ... + 300° C Tolerance: UNI 7937, IEC 751 standards: ± 0.15° C at 0° C for class A (1/2 DIN) ± 0.30° C at 0° C for class B (1 DIN) ± 0.10° C at 0° C for 1/3 DIN class Ceramic insulation of sensor, PT100 at 0° C Application versatility
- # of Lead Wires Per Element: 2, 3, 4
- Diameter or Width Range: 0.1969 to 0.4724 inch
- Element Configuration: Single Element, Double Element
- Element Material: Platinum
-
Supplier: Yageo Nexensos
Description: The Platinum Resistance Temperature Detector in a plastic housing is characterized by its standardized signal according to DIN EN 60751 (according to IEC 751), interchangeability, excellent long time stability and accuracy. It offers an optimal price-performance ratio in large
- Package Type / Mounting: Through Hole Technology (THT)
- RoHS Compliant: Yes
- Sensor Grade / Operating Range: Automotive, Industrial, Consumer
- Sensor Type: Temperature Sensor
-
Supplier: Baumer Ltd.
Description: The measuring principle in the Pt100 temperature sensor is based on the relationship between resistance and tem pe ra tu re in platinum. The platinum sensor is manufactured in accordance with DIN/EN/IEC 751, e.g. 0°C corresponds to 100 Ohm and 100°C to 138.5 Ohm. The sensors are
- Length: Up to 4.13 inch
- Operating Temperature: -58 to 401 F
- Sensor Technology: Wire Wound
- Width / Diameter: 0.2362 inch
-
Supplier: Yageo Nexensos
Description: resistance and a wide temperature range of -196°C to +500°C. C-type elements conform to the characteristic curve defined by DIN EN 60751 (according to IEC 751), and exhibit no hysteresis. These features make them best suited for applications in aerospace, chemical power
- Length: 0.1535 inch
- Nominal Resistance: 100 R0 @ 0° C
- Operating Temperature: -321 to 932 F
- Sensor Technology: Thin Film
-
Supplier: RCD Components, Inc.
Description: a single package (Type PTD) Meets DIN 43760 and IEC 751 Choice of temperature ratings (up to +640°C) SPECIAL MODIFICATIONS (Consult Factory) Non-standard resistance values up to 2000 ? Surface Mount chip elements Insulated extension wires Assembly into stainless steel probes
- Length: 0.1250 to 0.6750 inch
- Multi-element: Yes
- Operating Temperature: -58 to 1184 F
- Response Time: 0.0800 to 80 seconds
-
Supplier: RS Components, Ltd.
Description: Pt100 4 wire class B resistance thermometer with DIN B head. Various probe available lengths. 6mm diameter in 316 stainless steel. Stainless steel plug. Sensor temperature rating -100ºC to +450 ºC. Conforms to IEC 751 Sensor Type = PT100 Probe Length = 500mm Probe
- Length: 19.69 inch
- Nominal Resistance: 100 R0 @ 0° C
- Operating Temperature: -148 to 842 F
- Width / Diameter: 0.2362 inch
-
Supplier: RS Components, Ltd.
Description: Ambient and external resistance probes for air conditioning applications. Pt 100 in ceramic DIN IEC 751 Class B, 2- or 3-wire fitting. Mainly used to measure temperature inside and outside. For temperatures of between -30 and +80 °C (200 °C). Versions with 4 - 20 mA measurement
- Nominal Resistance: 100 R0 @ 0° C
- Operating Temperature: 32 to 140 F
- Wire Wound Types: Platinum
-
Supplier: RS Components, Ltd.
Description: DIN IEC 751 Class B ceramic Pt100 probes, 3-wire assembly. 316L stainless steel protective sheath. PTFE-silicone cable. Output protected by bending spring. Sensor Type = PT100 Probe Length = 200mm Probe Diameter = 6mm Minimum Temperature Sensed = -50°C Maximum Temperature
- Length: 7.87 inch
- Nominal Resistance: 100 R0 @ 0° C
- Operating Temperature: -58 to 392 F
- Width / Diameter: 0.2362 inch
-
Supplier: RS Components, Ltd.
Description: DIN IEC 751 Class B ceramic Pt100 probes, 3-wire assembly with screw terminals. 316L stainless steel protective sheath. Aluminium alloy connection head. Removable base allows for easy transmitter integration. Sensor Type = PT100 Probe Length = 150mm Probe Diameter = 8mm Minimum
- Length: 5.91 inch
- Nominal Resistance: 100 R0 @ 0° C
- Operating Temperature: -58 to 482 F
- Width / Diameter: 0.3150 inch
-
Supplier: Conax Technologies
Description: , and IEC 751, Class B tolerance. * High accuracy * Stock a single sensor for various applications * Fast delivery * 100 ohm Platinum RTD Sensor * Maximum service temperature: 400°F (204°C) * Available Lengths: . Minimum Sheath Length – 6 inches . Maximum Sheath Length – 5 feet .
- # of Lead Wires Per Element: 4
- Element Material: Platinum
- Probe Configuration: Straight Probe
- Probe Features: Available as an Assembly
-
Supplier: Cole-Parmer
Description: drive or transferred to PC through an USB cable. Wireless data transfer can be done with an added optional module. Both Precision Thermometers allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also
- Celsius Scale: -200 to 850 C
- Digital Technology Type: RTD Technology
- Fahrenheit Scale: -328 to 1562 F
-
Supplier: Cole-Parmer
Description: drive or transferred to PC through an USB cable. Wireless data transfer can be done with an added optional module. Both Precision Thermometers allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also
- Celsius Scale: -200 to 850 C
- Digital Technology Type: RTD Technology
- Fahrenheit Scale: -328 to 1562 F
-
Supplier: Cole-Parmer
Description: drive or transferred to PC through an USB cable. Wireless data transfer can be done with an added optional module. Both Precision Thermometers allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also
- Celsius Scale: -200 to 850 C
- Digital Technology Type: RTD Technology
- Fahrenheit Scale: -328 to 1562 F
-
Supplier: PR electronics
Description: functions are required. Linearized temperature measurement with Pt100 (to IEC 751) or Ni100 (to DIN 43760) sensors. Conversion of linear resistance change to standard analog current/voltage signal from for example valves or linear movements with attached potentiometer. Signal
- AC Input Voltage: 208 to 230 volts
- DC Output Current: 2 amps
- DC Output Power: 48 watts
- DC Output Voltage: 15 to 24 volts
-
Supplier: Enercorp Instruments Ltd.
Description: food service. Platinum RTD's Our standard smokehouse RTD's use one or two 100 ohm platinum thin film elements to DIN 43 760 (IEC 751) with a tolerance of ± 0.3°C. We also supply RTDS's with a tolerance of ± 0.1°C in values of 100 and 1000 ohms
-
Supplier: Enercorp Instruments Ltd.
Description: are available to special order. The sheath length must be specified at order time. Industrial Temperature Sensors standard assembly is rated for measuring temperatures up to 200°C. 400°C and 600°C versions are available to special order. We use a thin film RTD sensor to DIN 43 760 or
-
Supplier: Enercorp Instruments Ltd.
Description: be specified at order time, although 4" and 6" lengths are normally available from stock. The assembly is rated for measuring temperatures up to 200°C and uses a thin film RTD sensor to DIN 43 760 or IEC 751. This same construction is available in thermocouple versions if
- Basic Element Used: RTD
-
Supplier: U.S. Sensor
Description: from -50°C to +500°C. Higher temperature ratings are available by special order High accuracy: Resistance and temperature deviation can be controlled to within ±0.06% and ±0.15°C, a tolerance that corresponds to Class œA of IEC 751 or 1/2 DIN of DIN 43760
- Nominal Resistance: 100 to 1000 R0 @ 0° C
- Operating Temperature: -50 to 500 F
- Sensor Technology: Wire Wound, Thin Film
- Wire Wound Types: Platinum
-
Supplier: ValueTronics International, Inc.
Description: are supported. Also, DIN/IEC 751 Platinum RTDs are supported Totalize Events on the Totalizing Input Alarm Limits and Digital Output Alarm Indication 4-Terminal Resistance Measurements (Channels 1 through 10 only) RS-232 Computer Interface Operation
Find Suppliers by Category Top
More Information Top
-
Hot Plate Gas Sensors—Are Ceramics Better?
The temperature versus resistance characteristics were approximated with second-order polynomial according to the industry standard DIN IEC 751 :5 .
-
http://www.sigmaaldrich.com/etc/medialib/docs/Sigma-Aldrich/Instructions/1/ets-d5_manual.Par.0001.File.tmp/ets-d5_manual.pdf
±0,2 + Fühlertoleranz PT 1000 DIN IEC 751 Klasse A .
-
http://www.anton-paar.com/corp-en/products/details/density-sensors-l-dens-4x7-l-dens-427-also-with-class-1-div-1-atex-certification/density-sensor/?eID=documen...
Temperature range - sample Temperature measurement Accuracy in the adjusted range* -25 to +125 °C (T5: to +70 °C) Pt100 integrated (1/10 DIN IEC 751 CL.
-
http://www.anton-paar.com/corp-en/products/details/density-sensors-l-dens-4x7-l-dens-427-also-with-class-1-div-1-atex-certification/density-sensor/?eID=documen...
Temperature range - sample Temperature measurement Accuracy in the adjusted range* -40 to +125 °C (T5: to +70 °C) Pt100 integrated (1/10 DIN IEC 751 CL.
-
Millikelvin Thermometer: MKT 50 :: Anton-Paar.com
• DIN IEC 751 for industrial Platinum Resistance Thermometers (PRT .
-
Analysis of Boundary-Layer Statistical Properties at Dome C, Antarctica
Six Väisälä hygrometers (4 HMP155 and 2 HMP45AC), six pt100 DIN IEC 751 thermistors, and six Young 45106 aero- vanes were mounted at 3.6 m, 11 m, 18.6 m, 25.9 m, 33.2 m, and 42.4 m.
-
Building Refurbishment for Energy Performance
3 DIN IEC 751 :1983, Temperature/Resistance Table for Platinum Sensors .
-
Characterization of commercial-off-the-shelf electronic components at cryogenic temperatures
PT 100 sensors, according to DIN IEC 751 , have been used in order to measure the temperature of the different components in the printed circuit.
Indicates content that may require registration and/or purchase.