Products/Services for Fire Hydrant Bollards
-
Bollards - (206 companies)...bike lanes, and fire lanes, or they can be used to restrict access to certain areas. Figure 8: Bollards. Source: Kenneth Allen/CC BY-SA 2.0 Security Anti-ram bollards can protect people, property, and infrastructure from vehicle-based attacks... -
Traffic Safety Equipment - (375 companies)...vehicles or axles for traffic or traffic flow control. The sensor data would be fed into a traffic control or tolling system. Markers and indicators that are used in deep snow to locate fire hydrants and utility boxes are another example of traffic safety... -
Hydrants - (83 companies)Hydrants are valve devices that are used to dispense large volumes of liquid. Hydrants are valves made to deliver a large flow of water, hence its name "Hydrant " as it relates to water. Types of Hydrants. Fire Hydrants. The most common and visible... -
Fire Protection Services - (258 companies)...and nozzles. fire pump controllers. hydrants. non-water based chemical extinguishing systems. Some fire protection services install, monitor, and maintain pipe hangers, seismic sway-brace components for sprinkler systems, underground pipe and fittings...
-
Fire Sprinkler Heads - (80 companies)Fire sprinkler heads deliver a high-pressure flow of water or dry chemicals to a fire. They are usually are heat-activated and part of a larger fire prevention and safety system. Fire sprinkler heads deliver a high-pressure flow of water or dry... -
Fire Alarm Control Panels - (241 companies)Fire alarm control panels (FACPs) transmit signals between fire detection devices and alarms, suppression systems, and monitoring centers. This device reduces the potential for fatalities and property loss from structure fires. Fire alarm control...
-
Fire Suppression Systems - (269 companies)Fire suppression systems are used to suppress flames in the event of a fire. There are several types of suppression systems including wet sprinkler systems, dry sprinkler systems, deluge sprinkler systems and dry chemical suppression systems...
-
Flammability and Fire Testing Services - (47 companies)Flammability and fire testing services evaluate finished products or components through specialized environmental exposure tests. A number of industries take great interest and participate in costly implementations using flammability and fire...
-
Posts, Spacers, and Standoffs - (517 companies)Posts, spacers and standoffs are threaded and used in applications where boards, plates, or other items need to be fastened to each other.
-
Lamps - (1859 companies)Lamps are light sources that emit incoherent light for illumination. There are many different types of products. Examples include fluorescent lamps, halogen lamps, heat lamps, incandescent lamps, LED lamps, projection lamps, spectral lamps, and stage lamps. Specialized and proprietary lamps are also available.
Product News
-
McGard Special Products Division
McGard Super Strength Fire Hydrant Lock McGard's Hydrant Lock is a super strength ultimate security solution. Features & Benefits: Controls water access and usage. Easy installation and operation. No modification needed to existing hydrants. Machined from alloy steel and ductile iron. Operating wrench comes equipped with a standard fireman 's tool and McGard operating key head. Environmentally sealed and electro-plated to resist the elements. Not affected by weather extremes. Heavy duty models available for most hydrant types... (read more) -
Lowell Corporation
Ratcheting Hydrant Wrenches When a hydrant has to be opened in a hurry, Lowell's three rugged, ratcheting hydrant wrenches make the job faster and easier. Mount a wrench on a pentagonal or square nut, tighten the thumb screw, and you're in business. Long bolts or worn or frozen nuts? No problem. The Model 52F has a 15" iron handle, the Model 53F has a 20" iron handle, and the Model 252F has a stamped double handle and is 32 1/2" long. All three feature Lowell's heavy duty ratcheting mechanisms. The long handles of the 52F... (read more)Browse Wrenches Datasheets for Lowell Corporation -
InfraTec GmbH
Fire Prevention - FIRE-SCAN Fire Preven tion - FIRE-SCAN. Fire protection with thermography solutions for companies and the environment. Surveillance of open areas and warehouses with fire detection and prevention systems. Thermal imaging cameras timely detect and locate critical temperature conditions. Contactless, high-resolution temperature measurement at great distances for early fire detection and prevention. Automatic documentation and alerting. Monitoring objects and fire even in case of smoke and dusty air. follow... (read more)Browse Heat Detectors Datasheets for InfraTec GmbH -
LAND
Prevent Battery Fires Protect Your People, Protect Your Profits, Prevent Battery Fires. The burgeoning adoption of lithium-ion batteries across industries has ushered in a new era of energy efficiency. However, this technological advancement comes with a significant caveat: the heightened risk of thermal runaway and subsequent fires. At AMETEK Land, we're committed to safeguarding lives and assets by offering cutting-edge solutions to mitigate these dangers. Our latest innovation, the LWIR-640 smart radiometric... (read more) -
Isabellenhutte USA
Lowering The Risk of Battery Fires. vehicles require higher voltages and more electrical energy than in conventional cars with an internal combustion engine. As a result, the hazards caused by electric current increase, if the current flows are not precisely controlled. A battery management system that checks the state of charge and helps to prevent deep discharge or overload, either in the battery or in individual battery cells, provides monitoring, control and protection while also lowering the risk of battery fires. Isabellenh utte... (read more)Browse RTD Temperature Probes Datasheets for Isabellenhutte USA -
Insaco, Inc.
Designing with post-fired ceramics Working with ceramics? Start with the spec, not the guess. Designing with post-fired ceramics is different from designing with metal or plastic. The materials are harder, more brittle, and require different rules of engagement. That 's why we created a free Designer's Guide for engineers working with: - Sapphire. - Alumina. - Quartz. - Zirconia. - Macor. - and other hard materials. The guide covers everything from recommended minimum wall thickness to tolerancing best practices --based on 75... (read more)Browse Industrial Ceramic Materials Datasheets for Insaco, Inc. -
Acme Engineering Products
Gas Fired Steam Superheater ACME Steam Superheaters are available for operating pressures of up to 800 PSIG and temperatures up to 1200 deg. F. Steam flow is only limited by practical size considerations. Pressure sections are built to ASME code with National Board or CRN registration. Burners are AGA or CGA listed with UL, CSA or other gas train standards as requested or applicable. The ACME Steam Superheater is delivered to the site prewired and prepiped requiring only steam, gas, main power and stack connections. (read more)Browse Boilers (industrial) Datasheets for Acme Engineering Products -
Dexter Research Center, Inc.
Thermopiles...Fire Suppression / Detection Dexter Research Center, Inc. - Fire Suppression / Detection - Thermopiles from Dexter Research. A variety of products based on yoour specific requirements (8 products): Attributes include: Thin Film vs Silicon, Signal to Noise Ratio (SNR), Package Type, Number of Channels and more. More Information... 1M Series - A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas. 2M... (read more)Browse Thermopiles Datasheets for Dexter Research Center, Inc. -
Shanghai Thinktank Process Management Co., Ltd
Fire-Safe Thermal Shutoff Valve In hazardous processing environments, fire incidents and abnormal temperature rise can cause catastrophic leakage, fire escalation, and safety risks. Conventional valves may fail under extreme heat, leaving systems without reliable emergency isolation. This fire-safe valve is engineered to enhance protection in critical services: * Automatic thermal shut-off device that activates at preset fusing temperatures (74 C / 100 C). * API 607 fire-safe design to maintain sealing performance during fire... (read more)Browse Industrial Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
Control Instruments Corp.
Prevent Fires/Explosions in Scrubber Applications Add monitoring equipment like the PrevEx Flammability Analyzer to the outlet of your scrubber to stay safe. It's extremely short response time allows quick reaction to prevent fire or explosion. Read the case study to learn more. (read more)Browse Gas Instruments Datasheets for Control Instruments Corp.
-
Comparison of Nozzle and Flow Straighteners for Tank Waste Sluicing Applications Letter Report
The monitor was bolted to a steel skid, which was secured in place by butting it against a fire hydrant bollard and staking the other end to the pavement.
-
Comparison of Nozzles and Flow Straighteners for Tank Waste Sluicing Applications
The monitor was bolted to a steel ski~ which was secured in place by butting it against a fire hydrant bollard and staking the other end to the pavement.
-
The Facility Management Handbook
For example, identify all fire hydrants , shutoff valves, barricades, bollards , emergency phones, and gate access locations on a campus by their geographic digital locations so that information can be generated immediately through the computer.
-
CRACKING THE CODE OF SMALL DOWNTOWNS:
A comparison of four small downtowns and the codes used to shape their built form
The amount of street furniture, planters and other items including fire hydrants , benches, bike rack, bollards , railings, parking meters, trash cans, mailboxes etc. could be evaluated as fair within the study area and slightly better along King Street East (Figure 4-7…
-
AMS NBC-protection training unit
The PTU contains realistic training areas comprising the following: a large waterproofed area representing a surface warship upper deck, laid out with various equipment such as bollards , lockers, instrument pinnacles, a gun, hatches, fire hydrants and so on; a ship citadel airlock…
-
Chloride attack of reinforced concrete: an overview
The most vulnerable is the concrete wetted by sea water only occasionally, such as areas around bollards (where wet ropes are coiled) or in the vicinity of fire hydrants (using sea water), or in industrial areas subjected to periodic washdown with sea…
-
Facility Piping Systems Handbook: For Industrial, Commercial, and Healthcare Facilities, Third Edition > LIQUID FUEL STORAGE AND DISPENSING SYSTEMS
Bollards are the most often used and are similar to those used to protect fire hydrants .
-
States > Delaware > State > Regulations > Title 1 - Authorities‚ Boards and Commissions > 700 - Delaware State Fire Prevention Commission > [1 DE Admin C...
2.5.4 Minimum four inch (4") diameter steel bollards filled with concrete and marked yellow shall be installed at the outermost corners of the fire hydrant demarcation area.
-
Emergency Management for Facility and Property Managers > Fire Protection
There should be an exchange of information: such as providing the fire department with a plan of fire hydrant locations, fire department connection (FDC) locations, telephone numbers, points of contact, keys for locked gates or bollards , and location of "knox" boxes where…
-
Time-Saver Standards for Urban Design > Parking and circulation dimensions
Bollards at least 36 in. (~90 cm) tall or bumpers can be used to protect buildings, trees, fire hydrants or other structures within harm’s way.
Indicates content that may require registration and/or purchase.