Products/Services for Fluid Data Calorimeters
-
Calorimeters and Thermal Analyzers - (117 companies)Specific heat capacity is the measurement of heat a gram of a given substance needs to exchange with its surroundings under certain conditions in order to change its temperature by one degree. Calorimeters and thermal...Thermal Analyzer TypeCalorimeter TypeCooling Available -
Fluid Standards and Reference Fluids - (12 companies)Viscosity standards and reference fluids are oils, fluids, greases, or gels with stable and verified viscosity values and flow properties for calibration of viscometers, rheometers, and other standards. Viscosity standards and reference fluids...
-
Data Loggers and Data Recorders - (1128 companies)Data loggers and data recorders acquire digital data from sensors and other signals. They are primarily used to store data for subsequent downloads to a host PC, but may also include real-time features such as monitors and alarms. Data loggers... -
Fluid Couplings - (57 companies)Fluid couplings are torque-transmitting couplings that use hydraulic oil or water to transmit power. They differ from torque converters in that the input torque is equal to the output torque (no multiplication of torque). Fluid couplings are much...
-
Fluid Feedthroughs - (28 companies)Fluid feedthroughs use a hermetic seal to transmit fluids through the walls of a pressurized or vacuum system. Devices include nitrogen, air, and water feedthroughs. Fluid feedthroughs are designed to transmit fluids into high and ultrahigh vacuum... -
Data Acquisition - (2215 companies)Data acquisition is the digitizing and processing of multiple sensor or signal inputs for the purpose of monitoring, analyzing and/or controlling systems and processes. Signal conditioning includes the amplification, filtering, converting, and other...
-
Hydraulic Oils and Transmission Fluids - (363 companies)Hydraulic oils and transmission fluids are used to transmit power in hydraulic equipment and power transmission applications. Hydraulic oils and transmission fluids transmit power in hydraulic equipment and are used in power transmission...
-
Data Collection Terminals - (118 companies)Data collection terminals are portable or handheld devices that are used to input, read, and/or log data. They often have barcode and wireless data transmission capability. Data collection terminals are portable or handheld devices used to input...
-
Fluid Dispensing Equipment - (936 companies)Fluid dispensing equipment includes all manner of devices that dispense, mix and dispense, or mix, meter and dispense fluid media. Fluid dispensing equipment includes all manner of devices that dispense, mix and dispense, or mix, meter, and dispense...
-
Data Input Modules - (310 companies)Data input modules accept sensor and other signal output for data acquisition systems. They may include signal conditioning prior to the analog-to-digital conversion stage. About Data Input Modules. Data input modules receive signals from devices...
Product News
-
AMETEK Spectro Scientific
Hydraulic fluid analysis Hydraulic systems are used in industrial, mobile and aviation applications to transmit power to operate equipment. They are incredibly efficient, compact, and lightweight relative to a mechanical equivalent. Hydraulic fluids transmit force in the system, and as such are carefully chosen by the system maker. Chemical stability, high flash and fire points, viscosity, and oxidation resistance are all valued, and as a result mineral and synthetic hydrocarbon fluids are selected for mobile... (read more)Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
Hilliard Corporation (The)
Fluid Sample Analysis from HILCO Hilliard 's Fluid Sample Analysis provides a detailed evaluation of fluid condition, helping operators maintain system performance and extend equipment life through data-driven maintenance. Key benefits include: Comprehensive fluid evaluation: Tests identify the type, quantity, and severity of contaminants such as particulates, water, varnish, and degradation byproducts. Physical property analysis: Assesses viscosity, acidity, oxidation, and other key characteristics to determine fluid health... (read more) -
E-Labs, Inc.
Fluid Contamination Testing | Climatics Services . Experienced technical staff -- subject-matter experts in contamination control. Fast, reliable results -- actionable data you can trust. Custom test plans & thresholds -- tailored to your system or spec. Detailed reporting & consultation -- interpretation, recommendations & trends. Contact E-Labs today to discuss your Fluid Contamination Testing needs, request a quote, or learn more about how our services can protect your systems. (read more) -
Hamilton Company
Syringe Pumps - OEM Fluid Handling with ceramic, PTFE, and CTFE inserts for delivering chemically inert flow paths. Comprehensive selection of specialty syringes provide long life for the most precise and reliable fluid handling. Self-contained, bi-directional valve positioner with a wide choice of valves for easy replacement and accurate port alignment. Quick Links: Overview and data sheets for our extensive line of Syringe Pumps... Email our trained technicians your specific application questions or pricing inquiries... (read more)Browse Syringe Pumps Datasheets for Hamilton Company -
Assured Automation
Sanitary Valves and Data Centers Assured Automation 's Role in Data Centers. Assured Automation provides automated valve solutions that help data centers maintain reliable, responsive control across critical cooling, fire protection, and fluid-handling systems. Recommended Reading: Data Center Applications. For a deeper look at how Assured Automation applies valve automation specifically in data center environments, the following article is recommended: How Sanitary Valves Are Gaining Interest in Data Center Cooling Systems... (read more)Browse Sanitary Valves Datasheets for Assured Automation -
AGC Chemicals Americas, Inc.
Performance Materials for Data Centers enhance filtration media and protect equipment. These materials can: Provide electrical insulation and durability. Enable high-speed data transmission. Protect from aggressive fluids. Improve air handling performance. Follow us on: YouTube. LinkedIn. twitter. Our Blog. Watch > > >AGC Group Overview. ABOUT AGC CHEMICALS AMERICAS. For almost a century, AGC Chemicals has been manufacturing high-performance materials serving industrial customers. Already the world's largest, longstanding custom compounder... (read more)Browse Electrical and Electronic Resins Datasheets for AGC Chemicals Americas, Inc. -
AMETEK Spectro Scientific
Technologies Behind Portable Fluid Analysis System Downtime for critical equipment is costly in terms of dollar expense, productivity and human lives. Oil analysis is one of the most important and reliable techniques to keep these assets up and running. When deploying field solutions, careful consideration must be given to turnaround time, technique, and data integrity. The FieldLab Commercial series on-site oil analysis system provides fast results with the data integrity of a commercial oil analysis lab. The FieldLab is a rugged, portable... (read more)Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
AMETEK Spectro Scientific
FieldLab 58 Expeditionary Fluid Analysis System Florescence (XRF) spectrometer for elemental analysis. - Filter Particle Quantifier (FPQ) pore blockage particle counter. - Infrared (IR) spectrometer. - Kinematic viscometer (40 C). 4 tests generate more than 20 oil analysis parameters in less than 10 minutes. Built-in controller for measurement, data, and asset with touch screen interface. Uses only 12 mL of oil. ASTM compliant. Operating principles. Particle Count and Elemental Analysis -- ASTM D812. Particle counts are generated using our patented... (read more)Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
Waukesha Bearings
Custom Fluid Film Thrust Bearings - Hidrax HT hardness at oil bath temperatures of 300 C (572 F) and higher. The rated unit load of the Hidrax HT thrust bearing is 8 MPa (1160 psi). The design uses the well-proven Hidrax platform, with durable ceramic/cermet lining on the tilting pads and the thrust collar. The superior strength and hardness of ceramic/cermet materials also provide the ability to crush abrasive debris that may enter the system through damage to a mechanical seal or contamination of the lubricating oil. Technical Data. Rated... (read more)Browse Plain Bearings and Sleeve Bearings Datasheets for Waukesha Bearings -
Fuji Electric Corp. of America
HMI Displays for Data Center Monitoring HMI Units. Fuji Electric HMI 's provide the ability to closely monitor energy usage, and system status. Our HMI Displays aid in keeping you appraised of the health of your Data Center HVAC systems. The color touchscreen HMI display provides easy operation, as well as comprehensive information and diagnostics. View Products. View Flyer. Watch Video. Features & Benefits: Operation Log Function - Allows viewing of the operation procedures that cause defects and production settings based... (read more)Browse Human Machine Interfaces Datasheets for Fuji Electric Corp. of America
-
Flammability Screening and Fire Hazard of Industrial Fluids Using the Cone Calorimeter
These data support the likelihood that small scale test data on fluids in the cone calorimeter will have some relevance to larger scale processes.
-
Cryogenic Thermal-Conductivity Measurements of Insulating Materials
In order to insure that changes hi the equilibrium boiling points of the calorimeter fluid are small and will not introduce transients into the test data , control must be maintained over the calorimeter fluid vapor pres- sure.
-
Alternative refrigerants and refrigeration cycles for domestic refrigerators
This compressor calorimeter data is needed to help select the best fluids for additional testing and to ascertain if changes in RF prototype performance are attributable to the thermodynamics .
-
New products
Fluid - Data Inc. is marketing its Flo-Cal calorimeter which permits measurement of heat value in fuel gases in hazardous, Class I, Group C&D Electrical Division areas, in close proximity to blending and mixing facilities.
-
Production, characterisation and application of monosize alloy droplets
state.19 Above 0?46 m, the data and the simulation agreed because the droplets entered the calorimeter fluid after nucleation and recalescence had taken place, giving up most of their enthalpy to the calorimeter.
-
C6H12 and C6H14
…00050; ⌠(HE)/J mol-1 = 0.30 + 0.005 |HE/J mol-1| Raal, J. D.; Naidoo, P. Excess enthalpy measurements using a novel highly refined microflow calorimeter and the prediction of … liquid equilibria from such data Fluid Phase Equilib.1990,57…
-
C6H14 and C7H8
…30 + 0.005 |HE/J mol-1| See SELF for the totality of data Raal, J. D.; Naidoo, P. Excess enthalpy measurements using a novel highly refined microflow calorimeter and the prediction of … liquid equilibria from such data Fluid Phase Equilib.1990,57…
-
Power Systems For Space Flight > Inflatable Foam-Rigidized Approach To Solar Concentrators
…10-ft-diam concentrators* A typical calorimeter, as shown in Fig. 17, was used to determine the total energy available in the focal region* These data were obtained by simultaneous measurement of fluid -flow rate through the calorimeter and temperature rise in…
-
Application of Exchangeable Biochemical Reactors with Oxidase‐Catalase‐Co‐immobilizates and Immobilized Microorganisms in a Microfluidic Chip‐Calorimeter
The calorimeter contains an electronic control unit for data acquisition, automatic operation of fluid units and tempera- ture control.
-
Thermal analysis of biochemical systems
Although the long-term drift of these 40 experiments is large, the data does demonstrate the repeatability of the entire calorimeter system including the semi-automated fluid handling and temperature control.
Indicates content that may require registration and/or purchase.