Supplier: Newport MKS
Description: The 76992 is especially suited to laser or focal plane use and applications including beam modulation at frequencies up to 150 Hz in burst mode. Burst frequency rating is specified for four seconds maximum with one minute minimum between bursts. In continuous mode (defined as the
-
Description: Description / Abstract This standard defines the characteristics of front and focal-plane shutters which affect the control of exposure and motion-stopping ability of the shutter and the camera in which it is mounted. Tests suited for two general purposes are described;
-
Supplier: InfraTec GmbH
Description: flexibility Precise long-time measurements without shutter With its ImageIR® 8800, InfraTec offers another top-level thermographic camera model belonging to the ImageIR® high-end camera series. It is equipped with a cooled LWIR-focal-plane array photon detector that provides a
- Measurement Range: -40 to 2,000 C
- Spectral Range: 7.7 to 10.2 microns
- Accuracy: 1 ±% Full Scale
- Temperature Resolution: 0.024999999999999998 C
-
-
Supplier: Panavision, Inc.
Description: or 4-perf configurations to enable significant savings in film costs without compromising image quality. The camera has a crystal controlled speed range of 4-36 fps forward and reverse in 1/10 frame increments, along with a separate switch for 29.97 fps. A variable in-shot focal plane
- Maximum Frame Rate: 4 to 36 fps
- Application / Industry: Broadcast
- Monochrome / Color: Color
- Imaging Technology: Film
Find Suppliers by Category Top
More Information Top
-
Multilens Cameras For High Velocity/Low Altitude Photo Reconnaissance
After an outline of fundamentals of the multilens array combined with focal plane shutter and angle- correct FMC the KA -106() and KA -107C will be described.
-
Review of image-blur models in a photographic system using the principles of optics
Analysis of the effect of the focal plane shutter on the lens OTF can be analyzed by using the Huygens-Fresnel principle.
-
On the testing of a novel photographic shutter
…in keeping with the high standards of the National Physical Laboratory, but I am sure he will agree with me that there is something wrong with a formula that assesses at 90 per cent. a focal plane shutter which has distortion, and…
-
Simplified Streak/Strip And Scanning Photographic Systems
In this presentation the principles of slit shutter and scanning photographic techniques are related to ordinary focal plane shutter operation parameters.
-
Modeling of image shutters and motion blur in analog and digital camera systems
The Focal Plane Shutter is close to the focal plane, right in front of the sensor.
-
KS-121A CAMERA SYSTEM FOR THE FR-5A/E AIRCRAFT
Included are the two major mechanical elements: the focal plane shutter and the film transport (magazine).
-
An application of the photo-electric cell to a comparison of the efficiencies of photographic shutters
As the efficiency of a focal plane shutter can be determined theoretically from measurements of the width of the opening in the blind, the distance of the blind from the focal plane, and the relative effective aperture of the camera lens, the…
-
On the results of some tests on photographic shutters at the national physical laboratory
I n testing focal plane shutters a similar method is followed.
-
THE SOFT-FOCUS LENS AND ANGLO-AMERICAN
PICTORIALISM
6.19 Folmer & Schwing focal plane shutter .
-
Engineering Measurements: Methods and Intrinsic Errors
There are particular types of errors which can occur with this method when focal plane shutters (as on a typical SLR camera) are used, and these are covered in the same section.
Indicates content that may require registration and/or purchase.