Supplier: Electro Optical Components, Inc.
Description: Custom scintillation detectors assembly can be manufactured upon your request. Different scintillators and tubes can be integrated into gamma scintillation detectors. · NaI(Tl) scintillation detector 1”x1”,2”x2”,3”x3”,4”x4”x16” · LaBr3(Ce)/CeBr3 scintillation
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Electro Optical Components, Inc.
Description: CVD diamond is used as a radiation detector for medical and high energy physics applications. Major fields of application include medical dositry, neutron detectors, UV laser systems and X-ray and gamma detection. HIGH purity synthetic CVD Diamond presents unique
- Detectable Activity Range: 5,500 to 1 KeV
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray, Neutron, X-Ray
- Detector Style: Fixed Installation
-
Supplier: Micross Components, Inc.
Description: response to gamma radiation. This output can be used to protect electronic components. During gamma radiation, damage to both insulated gate (MOS) and PN junction (bipolar) devices may occur. The effects on electronic components can include, for example, reduction of
- Operating Temperature: -67 to 257 F
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
-
-
Supplier: Electro Optical Components, Inc.
Description: Detection of radioactive materials Reliable detection of low activities Energy range of gamma radiation: 40 keV – 3 MeV Sensitivity for gamma radiation: 662 keV, typical 2.4 cps/μSv/h Threshold setting range for photon Radiation: 0.15 – 3.60 μSv/h Dose rate range:
- Detectable Activity Range: 40 to 0.003 KeV
- Software: Application Software Included
- Features: Audio Alarm/Indicator
- Computer Interface: Computer
-
Supplier: Electro Optical Components, Inc.
Description: HZYH-01 standard handheld gamma spectrometer is mainly used to identify the types and categories of radionuclides in radioactive material on site, to detect and alarm gamma radiation level, and to search and locate radioactive sources. Our spectrometer is mainly aimed at the
- Detector Style: Detector Sensing Element Only
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Scintillation Detector
-
Supplier: Landauer, Inc.
Description: LANDAUER dosimeters feature our proprietary OSL dosimetry technology, and can be packaged for occupational radiation monitoring, area radiation monitoring, patient monitoring, emergency response or other services for healthcare.
- Type of Monitoring: Area Monitoring, Personnel Monitoring
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray, X-Ray
- Detector Output: Dose
- Types of Radiation Detectors: Dosimeter
-
Supplier: LND, Inc.
Description: Multi-Window Alpha/Beta/Gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: End Window-alpha-beta-gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: Gamma Detector
- Operating Temperature: -67 to 167 F
- Types of Ionizing Radiation Detected: Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: LND, Inc.
Description: Pancake Mica Window Alpha-beta-gamma Detector
- Operating Temperature: -40 to 167 F
- Types of Ionizing Radiation Detected: Alpha Particles, Beta Particles, Gamma Ray
- Types of Radiation Detectors: Geiger-Mueller Counter
-
Supplier: Data Device Corporation (DDC)
Description: DDC’s HSN-3000 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its outputs from the normal high state to a low state with a propagation delay
- Operating Temperature: -67 to 257 F
- Detector Style: Detector Sensing Element Only
- Detector Output: Dose Rate
- Types of Ionizing Radiation Detected: Gamma Ray, Neutron
-
Supplier: First Sensor AG
Description: Alpha, beta, gamma, and X-ray radiation can be detected with silicon PIN photodiodes either directly via the absorption in the crystal lattice or indirectly via the measurement of the luminescence radiation of a scintillation crystal. The Series X from First Sensor features
- Detectable Activity Range: 1 to 10,000 KeV
- Operating Temperature: -4 to 140 F
- Detector Output: Count Rate
- Detector Style: Detector Sensing Element Only
-
Supplier: Sentinel
Description: Die cast aluminum belt worn alarm. Dual range for continuous warning. Alarm output is 100 decibels at 6 inches.
- Features: Audio Alarm/Indicator
- Types of Ionizing Radiation Detected: Gamma Ray
- Type of Monitoring: Personnel Monitoring
- Detector Style: Portable Detector
-
Supplier: Sentinel
Description: Rugged, watertight, dustproof radiographic survey meter. Two piece nylon reinforced fiberglass case. Large 3.5 in Mil-Spec meter indicator. Meter face in both mR/hr and uSv/hr. Three Ranges: 0 to 10, 0 to 100 and 0 to1000 mR/hr
- Display Options: Analog
- Type of Monitoring: Area Monitoring
- Detector Output: Dose Rate
- Types of Ionizing Radiation Detected: Gamma Ray, X-Ray
-
Supplier: Sentinel
Description: Portable 120V AC hard wired or plug in area monitor Internal detector Non-adjustable trip point set at 2mR/hr Two 5 AMP 120V AC remote alarm outlets
- Display Options: Analog
- Type of Monitoring: Area Monitoring
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Mirion Technologies
Description: radiation detection and instrumentation. Mirion Dosimetry Services Division - Radiation monitoring services (x-ray badges) and dosimetry solutions for a wide range of applications Radiation monitoring services are the foundation of any radiation safety program. In
- Detectable Activity Range: 25 to 0.015 KeV
- Features: Audio Alarm/Indicator
- Types of Ionizing Radiation Detected: Beta Particles, Gamma Ray, Neutron, X-Ray
- Detector Output: Count Rate, Dose, Dose Rate
-
Supplier: Sentinel
Description: FEATURES Rugged and Reliable Nylon holster or optional see-through holster Removable rubber sleeve for extra protection Water resistant Low power technology (600 hour operation) LCD Screen can be rotated 180o Battery life indicator Large display with backlight Top alarm indication (Can be operated
- Detectable Activity Range: 45 to 0.0013 KeV
- Type of Monitoring: Area Monitoring, Personnel Monitoring
- Features: Audio Alarm/Indicator, Memory for Data Storage
- Computer Interface: Computer
-
Supplier: Ultra Energy
Description: Wide Measurement Range; Easy to Read Logarithmic Display; Sensitive, Stable Detection; Simple Electronics – Zero Maintenance; Easily Cleaned Stainless Steel Enclosure. The Ultra Electronics HC833 is a self-contained gamma monitoring system for use within shielded areas containing radioactive
- Display Options: Analog, Digital
- Type of Monitoring: Area Monitoring
- Detector Style: Fixed Installation
- Types of Ionizing Radiation Detected: Gamma Ray
-
Supplier: Bruker Corporation
Description: The deliberate or accidental release of radioactive material is an increasing threat to modern society. Terrorists fabricating and detonating a dirty bomb with radiological material is a common scenario for emergency services. Radiological material can be easily obtained from medical waste,
- Type of Monitoring: Area Monitoring
- Computer Interface: Computer
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
-
Supplier: Ultra Energy
Description: CMS Gamma is a compact, mains-powered, continuous monitoring station for measurement of gamma dose rate, providing essential, reliable information to personnel. It is designed for building, area and process monitoring in nuclear facilities.
- Type of Monitoring: Area Monitoring
- Computer Interface: Computer
- Display Options: Digital
- Detector Output: Dose Rate
-
Supplier: Ultra Energy
Description: ANV S2 radiation monitoring system has been developed by Ultra to supply a robust and affordable solution for land and sea applications. The system continuously checks the radiological environment both within the vehicle and external to the platform.
- Display Options: Analog, Digital
- Type of Monitoring: Area Monitoring
- Detector Style: Fixed Installation
- Types of Ionizing Radiation Detected: Gamma Ray
Find Suppliers by Category Top
Featured Products Top
-
precision components. With an approximately 1.7 times greater density than lead, tungsten guarantees radiation exposure is kept to a minimum. Benefits Of Using Tungsten Tungsten’s higher density means the material provides better gamma ray absorption and radiation shielding (read more)
Browse Radiation Shielding Datasheets for MarShield -
SemeaAlert-Gamma is a Personal Alarm for exposure to ionizing radiation hazards. It is designed to alert those who are concerned about accidental exposure to ionizing radiation hazards in the environment. This product features high sensitivity and a quick response time ( of about a second (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
SemeaAlert-Gamma is a Personal Alarm for exposure to ionizing radiation hazards. It is designed to alert those who are concerned about accidental exposure to ionizing radiation hazards (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc.
More Information Top
-
Carcinoma of the breast wire localisation post nuclear medicine sentinel lymph node imaging. Are radiologists receiving a significant dose?
Instantaneous dose-rate (IDR) measurements of patients were also made at the time of each wire localisation procedure using a Geiger counter/ radiation detector ( Gamma Scout , Eurami Group).
-
Neutrons from Piezonuclear Reactions
We used three types of detectors of ionizing radiation : geiger counter Gamma Scout [19] with a mica window transparent to α, β and γ radiation, and provided with two aluminium filters 1 mm and 3 mm thick, to screen α radiation and …
-
Piezonuclear Reactions
Measurements of ionizing (α, β and γ) radiation background were carried out by using three types of detectors : Geiger counter Gamma Scout [43] with a mica window transparent to α, β and γ radiation, and provided with two aluminium filters 1 mm …
-
MC and A instrumentation catalog
128 Scout Nuclear Material ID Kit 129 Gamma Spectrometer 130 SpectrometericDevice for the Gamma EnergyAnalysisand Flux Density Control 131 Spectrometric … … for Gamma EnergyAnalysis 132 Hand-Held AU-Weather Spectrometer of the NucIear Radiation 133 Installationfor the X … … SpectrometricSystem Based on Scintillation Detector .
-
Combined, solid-state molecular property and gamma spectrometers for CBRNE detection
… mass and type of material, the type and amount of shielding, the background radiation from natural and … The gamma spectrometer module in the C- Scout ™ (Figure 3) includes a solid-state detector , a low-power ASIC, and a microprocessor.
-
Combined, solid-state molecular property and gamma spectrometers for CBRN&E detection
The C- Scout ™ gamma spectrometer module is shown in Fig. 3. It includes a solid-state detector , a low-power ASIC, and a microprocessor and detects radiation in the energy range of 30 keV-3MeV with a resolution of 1.5% to 2.5% FWHM at 662 keV, which is superior to comparable …
-
Praxis Manned Spaceflight Log 1961–2006
In addition to Hennen's Terra Scout package, there was also a range of monitoring and observation experiments … The Shuttle Activation Monitor (SAM) measured the radiation environment on board the orbiter and its eect on gamma ray detectors .
-
SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output
For given camera and radiation parameters, a simulation of the scintillation camera output entails trac- ing the generation, transport and readout for an ensemble of gamma rays with fixed input position and/or direction. … and sub-states of the light paths (each volume and boundary of the detector ) are treated in … Development and testing of SCOUT was aided using process-flow diagrams (e.g., fig- ures 2 and …
-
Geiger Counter Calibration and Technical Advice For First Responders from International Medcom
For example, Americium 241 mostly emits alpha radiation as well as a little bit of low energy gamma radiation . Americium 241 is found in household smoke detectors and many industrial devices, and this radionuclide could easily … In fact, a few years ago, a boy scout gathered enough Americium 241 for a science experiment …
-
Nuclear Terrorism and National Preparedness
The Bio/Geo- Scout (see Fig. 9.9) allows the fast and reliable detection of radioactivity in food … A large volume (200 200 ) NaI detector (used in Marinelli-geometry) in combination with a Gamma spectroscope gives the possibility to detect six pre- defined nuclides like Americium, Cesium or Iodine. … to minimize the required sample time, the instrument should be placed at locations with low background radiation .
Indicates content that may require registration and/or purchase.