Products & Services

See also: Categories | Featured Products | More Information

More Information Top

Lock Indicates content that may require registration and/or purchase. Powered by IHS Goldfire

  • Carcinoma of the breast wire localisation post nuclear medicine sentinel lymph node imaging. Are radiologists receiving a significant dose?
    Instantaneous dose-rate (IDR) measurements of patients were also made at the time of each wire localisation procedure using a Geiger counter/ radiation detector ( Gamma Scout , Eurami Group).
  • Neutrons from Piezonuclear Reactions
    We used three types of detectors of ionizing radiation : geiger counter Gamma Scout [19] with a mica window transparent to α, β and γ radiation, and provided with two aluminium filters 1 mm and 3 mm thick, to screen α radiation and …
  • Piezonuclear Reactions
    Measurements of ionizing (α, β and γ) radiation background were carried out by using three types of detectors : Geiger counter Gamma Scout [43] with a mica window transparent to α, β and γ radiation, and provided with two aluminium filters 1 mm …
  • MC and A instrumentation catalog
    128 Scout Nuclear Material ID Kit 129 Gamma Spectrometer 130 SpectrometericDevice for the Gamma EnergyAnalysisand Flux Density Control 131 Spectrometric … … for Gamma EnergyAnalysis 132 Hand-Held AU-Weather Spectrometer of the NucIear Radiation 133 Installationfor the X … … SpectrometricSystem Based on Scintillation Detector .
  • Combined, solid-state molecular property and gamma spectrometers for CBRNE detection
    … mass and type of material, the type and amount of shielding, the background radiation from natural and … The gamma spectrometer module in the C- Scout ™ (Figure 3) includes a solid-state detector , a low-power ASIC, and a microprocessor.
  • Combined, solid-state molecular property and gamma spectrometers for CBRN&E detection
    The C- Scout ™ gamma spectrometer module is shown in Fig. 3. It includes a solid-state detector , a low-power ASIC, and a microprocessor and detects radiation in the energy range of 30 keV-3MeV with a resolution of 1.5% to 2.5% FWHM at 662 keV, which is superior to comparable …
  • Praxis Manned Spaceflight Log 1961–2006
    In addition to Hennen's Terra Scout package, there was also a range of monitoring and observation experiments … The Shuttle Activation Monitor (SAM) measured the radiation environment on board the orbiter and its e€ect on gamma ray detectors .
  • SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output
    For given camera and radiation parameters, a simulation of the scintillation camera output entails trac- ing the generation, transport and readout for an ensemble of gamma rays with fixed input position and/or direction. … and sub-states of the light paths (each volume and boundary of the detector ) are treated in … Development and testing of SCOUT was aided using process-flow diagrams (e.g., fig- ures 2 and …
  • Geiger Counter Calibration and Technical Advice For First Responders from International Medcom
    For example, Americium 241 mostly emits alpha radiation as well as a little bit of low energy gamma radiation . Americium 241 is found in household smoke detectors and many industrial devices, and this radionuclide could easily … In fact, a few years ago, a boy scout gathered enough Americium 241 for a science experiment …
  • Nuclear Terrorism and National Preparedness
    The Bio/Geo- Scout (see Fig. 9.9) allows the fast and reliable detection of radioactivity in food … A large volume (200 200 ) NaI detector (used in Marinelli-geometry) in combination with a Gamma spectroscope gives the possibility to detect six pre- defined nuclides like Americium, Cesium or Iodine. … to minimize the required sample time, the instrument should be placed at locations with low background radiation .