Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ifm electronic gmbh
Description: Accurate flow measurement of ultrapure water, water, oils and glycol solutions A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance Can be used for mobile applications User-friendly communication and parameterisation via
- Media Temperature Range: -40 to 248 F
- Liquid Volumetric Flow Rate: 63.4 GPM
- Operating Pressure: 1,450.377 psi
- Operating Temperature: -13 to 140 F
-
Supplier: Radwell International
Description: FLOW METER, MEASURING RANGE: 7-360 GPH, 3/4 INCH THREADED NPT CONNECTION, 2 DIGITAL OUTPUTS, 1 ANALOG OUTPUT, MEDIA: LIQUIDS/WATER/GLYCOL SOLUTIONS/COOLANTS, PRESSURE RATING: 40 BAR, MEDIUM TEMPERATURE: 14-212 DEGREES FARENHEIT, 18-30 VDC. FREE 2 YEAR RADWELL WARRANTY
- Process Media Type: Gas
-
Supplier: Badger Meter
Description: The Universal meters use an oscillating piston to measure SAE 5…50 motor oils, SAE 80…240 gear oils, and antifreeze fluid (ethylene glycol). Used primarily as an inventory control device in lubricant dispensing systems, they are accurate, rugged, and lightweight. Accurate, Rugged, &
- Liquid Volumetric Flow Rate: 0.4 to 4 GPM
- Operating Pressure: 0 psi
- Mass Flow Rate: 0.000882 to 0.00882 lbs/min
- Mass Flow Rate Range: 0.000882 to 0.00882 lbs/min
-
-
Supplier: ifm efector inc.
Description: Reliable detection of flow and medium temperature Suitable for water, oils and glycol solutions For installation in pipes With two programmable switching outputs Clearly visible numerical display Learn more Article to be discontinued Discontinuation date: 12/31/2025 Alternative articles:
- Media Temperature Range: 14 to 176 F
- Liquid Volumetric Flow Rate: 13.2 GPM
- Operating Pressure: 232.06032 psi
- Operating Temperature: 14 to 140 F
-
Supplier: Macnaught USA, Inc.
Description: Macnaught MT Overview Macnaught MT Turbine Flow Meters are Heavy Duty Industrial Grade Velocity Flow Fluid Measuring Devices. Our MT Meters utilize decades of proven cost-effective technology. Additionally, each meter is machined from solid 316 Stainless Steel Billet for
- Liquid Volumetric Flow Rate: 0.75 to 1,200 GPM
- Operating Pressure: 800 to 5,000 psi
- Operating Temperature: -100 to 150 F
- End Fittings: Flanged, Threaded
-
Supplier: Badger Meter
Description: The Hedland® water-based fluid meter is designed to monitor fluid flow rates of water and oil emulsions, including glycol mixtures, water-in-oil, glycerin and other various coolants. Meter Flexibility. Accurate Fluid Monitoring. The Hedland water-based fluid meter
- Pipe Diameter: 0.25 to 3 inch
- Liquid Volumetric Flow Rate: 0.02 to 300 GPM
- Mass Flow Rate: 0.0000441 to 0.6615 lbs/min
- Operating Temperature: -20 to 240 F
-
Supplier: Meter Group
Description: NEW Bench-Top Water Activity Meter for Measuring Volatiles The AquaLab 4TEV is designed specifically for measuring formulations that include volatiles such as propylene glycol and ethanol. The dual sensor block uses both a chilled-mirror dewpoint sensor and a capacitance sensor for
- RH/aw Range: 5 to 100 %
- RH/aw Accuracy: 0.3 to 1.5 %
- Operating Temperature: 41 to 122 F
- Technology: Capacitive, Infrared
-
Supplier: Macnaught USA, Inc.
Description: and 2” stocked sizes Designed for Precise Volumetric Clean Process Fluid Totalizing Measurement No Flow Conditioning – put the meter where you need it Large Stock of Meter and Display Inventory including Hazard Classification Meters Immediate response to Flow Meter
- Liquid Volumetric Flow Rate: 0.5 to 32 GPM
- Operating Pressure: 500 psi
- Operating Temperature: 176 F
- End Fittings: Flanged, Threaded
-
Supplier: Macnaught USA, Inc.
Description: Macnaught MX Overview Macnaught MX Oval Gear Flow Meters are Industrial Grade Positive Displacement Flow Meter devices. Our MX Meters provide true volumetric measurement of liquid thru the meter – not of scale, but actual flow measurement. MX Meter bodies are
- Liquid Volumetric Flow Rate: 0.00216666666666667 to 320 GPM
- Operating Pressure: 175 to 2,000 psi
- Operating Temperature: 248 F
- End Fittings: Flanged, Threaded
-
Supplier: Panametrics
Description: The TransPort PT900 portable ultrasonic liquid flow meter is Panametrics’ newest portable clamp-on flow meter. It easily attaches to the piping fixture to measure flow within the pipe. Users have no need to cut into the pipe and cause delays and downtime. The PT900 can also be used to
- Pipe Diameter: 0.5 to 300 inch
- Media Temperature Range: -328 to 752 F
- Velocity Flow Rate: 0.0984251968503937 to 39.993438320209975 ft/sec
- Operating Temperature: -4 to 131 F
-
Supplier: Panametrics
Description: The Panametrics DigitalFlow DF868 is a fixed-installed liquid flow meter designed for measuring energy and flow in all industries. Using its own patented digital signal processing, Transit-Time, the DF868 provides drift-free measurements in ultrapure and most dirty liquids, such as fluids
- Pipe Diameter: 0.5 to 300 inch
- Media Temperature Range: -328 to 1,112 F
- Operating Pressure: 0 to 3,000 psi
- Velocity Flow Rate: -40.026246719160106 to 40.026246719160106 ft/sec
-
Supplier: FLEXIM AMERICAS Corp.
Description: concentrated sulfuric acid Measurement of hot liquids, such as heat transfer media (water/glycol at 480°F) and thermal oils
- Pipe Diameter: 0.25 to 432 inch
- Media Temperature Range: -40 to 390 F
- Operating Temperature: -4 to 140 F
- Media Temperature: -40 to 390 F
-
Supplier: Clark Solutions
Description: movement. Our flow meters are suited to a wide range of applications where affordability, reliability and ruggedness are important considerations. Liquid flow meters are suitable for potable and nonpotable water, irrigation water, glycol-water mixtures, fuel oils, lubricating
- Pipe Diameter: 0.25 to 8 inch
- Gas Volumetric Flow Rate: 0.166666666666667 to 66.6666666666667 SCFM
- Operating Temperature: -80 to 350 F
- Operating Pressure: 10 to 400 psi
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the density or relative density of glycols, glycerin, heat transfer fluids, engine coolant concentrates, and aqueous engine coolants. 1.2 This test method should not be applied to samples so dark in color that the absence of air bubbles in the
-
Supplier: Cole-Parmer
Description: • Built-in 1000
RTD sensor provides direct temperature measurement of media • Rugged PPA molded construction • Excellent media compatabilty These economical vortex flowmeters are suitable for water and water glycol-based heat exchange systems. The transmitters work on the vortex - Liquid Volumetric Flow Rate: 3.96 GPM
- Operating Temperature: 41 to 365 F
- Operating Pressure: 261 psi
- Meter Technology: Vortex (Shedding) Meter
-
Supplier: OMEGA Engineering, Inc.
Description: The FV100 Series vortex flow meters are inline flow meters that utilizes the vortex shedding measuring principle. The fluid strikes a bluff body which imparts alternating vortices downstream of the bluff which create a pressure on a sensor body containing a piezoelectric crystal. The
- Pipe Diameter: 0.25 to 4 inch
- Media Temperature Range: 210.2 F
- Liquid Volumetric Flow Rate: 0.4 to 200 GPM
- Operating Pressure: 200 to 300 psi
-
Supplier: Cole-Parmer
Description: • Built-in 1000
RTD sensor provides direct temperature measurement of media • Rugged PPA molded construction • Excellent media compatabilty These economical vortex flowmeters are suitable for water and water glycol-based heat exchange systems. The transmitters work on the vortex - Liquid Volumetric Flow Rate: 39.6 GPM
- Operating Temperature: 41 to 365 F
- Operating Pressure: 261 psi
- Meter Technology: Vortex (Shedding) Meter
-
Supplier: Cole-Parmer
Description: • Built-in 1000
RTD sensor provides direct temperature measurement of media • Rugged PPA molded construction • Excellent media compatabilty These economical vortex flowmeters are suitable for water and water glycol-based heat exchange systems. The transmitters work on the vortex - Liquid Volumetric Flow Rate: 13.2 GPM
- Operating Temperature: 41 to 365 F
- Operating Pressure: 261 psi
- Meter Technology: Vortex (Shedding) Meter
-
Supplier: ASTM International
Description: density meter, ethylene glycols and propylene glycols analyses, and inductively couple plasma-atomic emission spectroscopy tests shall be performed.
-
Supplier: Envent Engineering Ltd.
Description: Foul resistant. The M70 offers industry leading value in price while still maintaining reliability. The rugged sensor is resistant to chemical fouling such as amines and glycols and methanol and can be washed with alcohol without permanent damage.
- Operating Temperature: 32 to 122 F
- Moisture Content Accuracy: 2 ±%
- Electrical Outputs: Analog Current
- Display: Digital Readouts
-
Supplier: Burger & Brown Engineering, Inc.
Description: BTU's per Minute Calculation with Optional Glycol % Input 3/8", 1/2", 3/4" and 1" NPT(F) or BSPP(F) flow connection sizes Local or remote mount user interface Pressure gauges are available Specifications Connection Size Flow Range LPM Flow Range GPM 3/8" & 1/2" 1 to 15 .3 to 4 3/8" & 1/2" 2
- Features: Liquid
-
Supplier: CEF Industries LLC
Description: motor cavity to provide heat transfer and bearing lubrication. Utilizing hydrodynamic bearings, these pumps eliminate shaft seals and have an unusually long life pumping oil, coolanol, ethylene glycol and water.
- Maximum Discharge Flow: 0.85 to 10 GPM
- Maximum Discharge Pressure: 38 to 120 psi
- Media Temperature: -40 to 185 F
- Power Source: AC Powered
-
Supplier: Process Technology
Description: Provides general control for consistent plating and etch rates in most aqueous processes. FEATURES Large, easy to read dial.. Fluoropolymer (FEP) covered 5-foot (1.5m) copper bulb and capillary provided standard with the control. Provides extended service in corrosive liquids. Ethylene glycol
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Number of Zones (if applicable): 1 zones
- Temperature: Heating Control
-
Supplier: Process Technology
Description: Provides general control for consistent plating and etch rates in most aqueous processes. FEATURES Large, easy to read dial. Fluoropolymer (FEP) covered 5-foot (1.5m) copper bulb and capillary provided standard with the control. Provides extended service in corrosive liquids. Ethylene glycol
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Number of Zones (if applicable): 1 zones
- Temperature: Heating Control
-
Supplier: Vaisala
Description: functional temperature range is from -196°C to +90°C. The probe is compatible with the VaiNet RFL100 wireless temperature data logger. The TMP115 probe comes with a 0.5 or 3 meter cord and has several cable options to meet your application needs. For more details, please refer to the Order
- Sensed Temperature: -320.8 to 194 F
- Diameter or Width Range: 0.55 inch
- Reference Resistance: 100 Ohms (Most Common)
- Probe Features: Available as an Assembly, Tip Sensitive
-
Supplier: Process Sensing Technologies USA
Description: liquid analyzers may be combined via the multi-channel control unit. Features: Simple, cost efficient operation and low-maintenance Immune to chemical attack from H2S, mercaptans and other sulphides Protected against glycol or other liquid contaminants Accurate direct dew-point measurement at
- Operating Temperature: -40 to 140 F
- Instrument Type: Analyzer
- Display: Digital
- Application: Process Gas
Find Suppliers by Category Top
Featured Products Top
-
. ifm's SU ultrasonic flowmeter and SM magnetic inductive flow meter offer (read more)
Browse Liquid Flow Meters Datasheets for ifm efector inc. -
– Features one or two layers of high-strength steel wire braiding for superior pressure resistance and flexibility. Wide Media Compatibility – Suitable for petroleum-based hydraulic oil, water, ethylene glycol, lubricating oil, and air (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
-medium Compatibility: Compatible with petroleum-based hydraulic oil, lubricating oil, water, ethylene glycol and compressed air, one hose meets multiple fluid transmission demands, simplifying customer spare parts inventory management. Reliable Quality & Customization (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
, wear-resistant and durable, suitable for harsh working conditions such as mining and construction Full-Media & Wide Temperature Adaptation: Compatible with petroleum-based hydraulic oil, water, ethylene glycol and other media, stable operation from (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
– Synthetic rubber tube and cover withstand -40°F to 250°F (-40°C to 121°C), resisting petroleum-based oils, water, ethylene glycol, lubricants, and air. Predictable performance – Meets SAE J517 100R17 and ISO 9001 quality standards, ensuring consistent (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
high-pressure conditions, avoiding leakage risks and guaranteeing operational safety Full-Scenario Media Compatibility: Suitable for petroleum-based hydraulic oil, water, ethylene glycol, lubricating oil, air and other media, no need for frequent hose (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
machinery (tractors) and other fields, suitable for petroleum-based hydraulic oil, water, ethylene glycol, lubricating oil, air and other multi-media transmission needs. Super High-Pressure Resistant Structure: Synthetic rubber inner tube + two braids of steel wire (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
hydraulic presses, and heavy machinery hydraulic circuits. Multiple Media Compatibility Works safely with petroleum-based hydraulic oil, water, ethylene glycol, lubricating oil, and air. This versatility allows professional buyers to stock one hose type for multiple fluid (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
-based hydraulic oil, water, ethylene glycol, lubricating oil, air, and more. One single assembly type covers multiple working conditions, significantly reducing spare parts inventory and improving overall equipment operation and maintenance efficiency. Stable (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd. -
hose ensures superior performance. Applications 1.Applicable media:Petroleum based hydraulic oil, Water, Ethylene glycol, Lubricating oil, Air and Water 2.Inner tube: Synthetic rubber 3.Reinforcement: One braid of steel wire 4.Cover:Synthetic rubber 5 (read more)
Browse Hydraulic Hose Datasheets for Ningbo TIP Fluid Technology Co., Ltd.
Conduct Research Top
-
Propylene Glycol Precision Batching
Client needed highly accurate batching devices for precise metering of PG binders with a number of other blended chemistries. Common in fragrance, food, pharmaceutical and aerosols - this process loop manufactures vaporization products
More Information Top
-
On Farm Methods of Biodiesel Blend Detection
Commercially a hydrometer similar to an ethyl glycol meter could significantly reduce this cost and could be made readily accessible to the farmer.
-
TULSA UNIVERSITY PARAFFIN DEPOSITION PROJECTS
Glycol Flow Meter .
-
Mensa Project: System Design and Operation
Condensate removed from the glycol is metered and reinjected into the export oil lines.
-
TULSA UNIVERSITY PARAFFIN DEPOSITION PROJECTS
Glycol Flow Meter .
-
The choice of a thermostatic expansion valve for a CFC12 refrigeration system retrofitted with HFC134 a
WATER/ GLYCOL fLOW METER .
-
Development and Application of Insulating Packer Fluids in the Gulf of Mexico
12 – Glycol orifice meter ; 13 – 250-ton refrigeration unit; .
-
At-line process monitoring of polyester production by mid-IR spectroscopy
For production batches the desired quantity of glycols were metered into the reactor as warm liquids.
-
Effects of fenvalerate on field- and laboratory-developed estuarine benthic communities
Technical grade fenvalerate (100%) dissolved in a stock solu- tion consisting of 15% acetone and 85% triethylene glycol was metered by syringe pump into and mixed with the seawater entering the center of the constant-head box of each apparatus receiving fenvalerate.
-
Isolation and identification of the volatile sulphides produced during chill‐storage of north sea cod ( gadus morhua )
2 metre Carbowax 1540 on AW-DCMS Chromosorb W, 80-100 mesh, 8 :92 and 2 metre polypropylene glycol LB 550-X on Chromosorb W, 80-100 mesh, 15 : 85.
-
Surface Facilities Considerations for the Production of a Large Sour Gas Resource and the Injection of Sour and/or Acid Gas
13.5 m3 of stripping gas per cubic metre of glycol being supplied in a separate glycol stripper.
Indicates content that may require registration and/or purchase.