Supplier: Thermon, Inc
Description: Circulation heaters are the equivalent to tube and shell heat exchangers with the particular feature that the core bundle is manufactured with electric tubular heating elements. Circulation heaters are used in applications where a process stream needs to be heated
- AC Voltage Required: Up to 660 volts
- Applications: Gases / Vapors, Medium Weight Oils
- Heater Type: Circulation Heater, Duct Heater, Tubular Heater
- Maximum Operating (Sheath) Temperature: Up to 1200 F
-
Supplier: Infinity Fluids Corp.
Description: heaters on the market. From 12 Volts to 600 Volts, from 50 watts to 500,000 watts, Infinity CRES heaters are the solution to all of your challenging applications. This patented product was developed around the CRES electric heater design and placed into a flow housing
- AC Voltage Required: 120 to 480 volts
- Applications: Gases / Vapors, Clean Water Heating, Process Waters, High Purity Waters
- Heater Type: Air Heater, Circulation Heater, Inline Heater, Water Heater
- Heating Capacity: 0.2500 to 10 kW
-
Supplier: Infinity Fluids Corp.
Description: Heating Nitrogen is a critical process, which requires a heater of minimal Watt Density (WSI), less than 25 watts/square inch is required to heat Nitrogen safely. All Infinity CRES-SFC Heaters provide the necessary WSI to safely heat all forms of gases. Units which use
- AC Voltage Required: 120 to 480 volts
- Applications: Drying, Gases / Vapors, Clean Water Heating, Process Waters, High Purity Waters
- Heater Type: Air Heater, Circulation Heater, Explosion Proof Heater, Inline Heater, Water Heater
- Heating Capacity: 0.2500 to 10 kW
-
-
Supplier: Backer Hotwatt Inc.
Description: Features The Pure Flow Air Heater is designed for applications where clean air is necessary, as in laboratories and environmental testing areas. This heater is unique in supplying non-contaminated heated air. The stream of air is heated by passing over an enclosed
- AC Voltage Required: 120 to 240 volts
- Applications: Other
- Heater Type: Air Heater, Heat Torch
- Heating Capacity: 0.1000 to 1.2 kW
-
Supplier: Thermon, Inc
Description: Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil designs, duct
- AC Voltage Required: 120 to 600 volts
- Heater Type: Air Heater
- Phase: Single Phase
- Sleeve (Sheath) Material: Steel
-
Supplier: OMEGA Engineering, Inc.
Description: The AHPF series heaters are used to heat low flows of air, gas, water, or aqueous solutions. Applications include those where clean air is necessary, as in laboratories and environmental testing areas. The stream of air is heated by passing over an enclosed heated surface rather
- AC Voltage Required: 120 to 240 volts
- Applications: Other
- Heater Type: Air Heater, Duct Heater
- Insulation Options: No Insulation
-
Supplier: UL Standards & Engagement
Description: 1.1 These requirements cover fixed electric duct heaters, and remote control assemblies for such equipment, rated at 600 volts or less to be employed in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70. 1.2 These requirements do not cover fan-coil units
-
Supplier: Berner International Corporation
Description: function check. The fan starts, directing a high velocity stream of hot air that heats the incoming cold air. Engineered for versatility the door heater can be mounted at any angle between horizontal and vertical to satisfy most applications. All heaters are factory
- AC Voltage Required: 208 to 480 volts
- Heater Type: Air Heater
- Maximum Air Flow: 6500 to 7900 SCFM
- Phase: Single Phase, Three Phase
-
Supplier: XeteX, Inc.
Description: to perform on-the-fly calculations of mass flow rate. Heating was accomplished with a super-efficient double-pass heat exchanger, and an electric heater with modulating SCR controls. These components provided a supply air stream at the specified conditions and with the
- Application: Residential
- System Type: Heat Recovery Ventilator (ERV)
-
Supplier: ASTM International
Description: stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1.3 Limitations
-
Supplier: ASTM International
Description: stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1.3 Limitations
-
Supplier: ASTM International
Description: in the stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1
-
Supplier: ASTM International
Description: stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1.3 Limitations
-
Supplier: SAE International
Description: evaporation. The thermal decomposition of the nitric acid produced a nitrogen dioxide rich stream that then reacted with metered diesel fuel over two automotive-style, platinum based, three way catalysts (TWCs). In the laboratory, heat energy for acid evaporation and reduction was
Find Suppliers by Category Top
Featured Products Top
-
The Cata-Dyne™ LH Line Heater prevents equipment freezing and possible hydrate formation during pressure reduction at natural gas regulating sites. The Cata-Dyne™ Line Heater heats the gas stream using infrared radiant heat transfer, eliminating the use of burners, glycol fluid and (read more)
Browse Explosion Proof Heaters Datasheets for Thermon, Inc -
Circulation heaters are the equivalent to tube and shell heat exchangers with the particular feature that the core bundle is manufactured with electric tubular heating elements. Circulation heaters are used in applications where a process stream needs to be heated to a finely controlled set (read more)
Browse Circulation Heaters Datasheets for Thermon, Inc -
cylinders as possible in order to heat and wrap from the hottest exhaust gases stream. Process of heating the sensor slows down the regulation process of the onboard controller because of the feedback. In addition, using the exhaust pipe as a signal ground requires sensor’s thread to be coated with (read more)
Browse Industrial Heaters Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil designs, duct (read more)
Browse Duct Heaters Datasheets for Thermon, Inc -
INDIRECT ELECTRIC TANK HEATER Indirect Electric Tank Heaters are designed to heat tank contents indirectly without the need to drain the tank for heater replacement. These heaters use open coil heater elements supported by high temperature ceramics. The elements slide inside of a (read more)
Browse Coil Heaters Datasheets for Gaumer Process -
Learn about electric heat and types of electric heaters as well as heat transfer, heat losses, basic heat equations, specific applications with example and watt density in a five page PDF. (read more)
Browse Electric Heaters Datasheets for Backer Hotwatt Inc. -
The simplest definition of an electric heater is any device that changes electrical energy into heat energy. But from that simple explanation, electric heaters explode into a myriad of types, sizes, applications, and designs depending upon what’s being heated, the degree of (read more)
Browse Electric Heaters Datasheets for Backer Hotwatt Inc. -
Indirect Electric Tank Heaters are designed to heat tank contents indirectly without the need to drain the tank for heater replacement. These heaters use open coil heater elements supported by high temperature ceramics. The elements slide inside of a pipe that is welded to the mating (read more)
Browse Explosion Proof Heaters Datasheets for Gaumer Process -
White paper: Role of electric heaters in chillers refrigeration heater Description: This white paper details how heat plays an essential role in the chilling process, making electric heaters an ideal solution for chilling applications. Download today! (read more)
Browse Electric Heaters Datasheets for WATTCO -
immersion heater is an electric heating apparatus consists of a bundle of tubular heating elements which are submerged in a tank or container to heat a liquid, such as water, oils of various viscosity, viscous materials, solvents, process solutions, liquidous chemicals, and (read more)
Browse Immersion Heaters Datasheets for Gaumer Process
More Information Top
-
Economy of a lastganggerechten regenerative industrial power supply
Increase of the cover with renewable current. The use of Power-to-Heat, by which in heat an electrical process heater current converts ●.
-
Thermal transfer
it carries • By ˙q∗ W = const for an increase of the temperature of the radiator by unchanged heat flux .
-
Thermal transfer
It carries W = const for an increase of the temperature of the radiator by unchanged heat flux .
-
Evaluation of 241-AZ tank farm supporting phase 1 privatization waste feed delivery
Upon exiting the HEME, the gas stream is heated by electric heaters to protect the downstream HEPA and HEGA filter banks.
-
Some hydrogen-control considerations for ice-condenser nuclear plants. [PWR]
The air stream is heated by electric heaters to about 1300°F, requiring 5 MW of electric input for the 50 units.
-
Thorium utilization program. Quarterly progress report for the period ending May 31, 1977
An electric heater will heat the stream to about 350°C to prepare for NO conversion.
-
Room climate technique
There are also extending data for room heating surfaces with the heat outputs and water currents of radiators (see the table D2.6-4).
-
Physics for engineers
For exercise Ü 3.5-1 Which 's convective heat flux , does a vertical plate radiator with the height h = 0,6 m and the width b give off = 1,2 m turbulently to the Umgebungs air when the uniform surface temperature…
-
Experimental and numerical studies of the lower flammability limit of mixtures of C1–C5 hydrocarbons with air
For this, the outer tubes of the burner were equipped with electric heaters which heated the blowing stream , and the latter, in turn, heated the inner tubes of the burner and the combustible mixture.
-
An Investigation of EGR Treatment on the Emission and Operating Characteristics of Modern Diesel Engines
The EGR stream was heated up with the electric heater (set at 0.75 kW) to enable catalytic reactions.
Indicates content that may require registration and/or purchase.