Supplier: Infinity Fluids Corp.
Description: market. From 12 Volts to 600 Volts, from 50 watts to 500,000 watts, Infinity CRES heaters are the solution to all of your challenging applications. This patented product was developed around the CRES electric heater design and placed into a flow housing designed specifically to
- AC Voltage Required: 120 to 480 volts
- kWatts: 0.25 to 10 kW
- Flange or Thread Diameter: 0.25 to 0.5 inch
- Inlet and Outlet Separation: 12 to 16 inch
-
Supplier: Infinity Fluids Corp.
Description: Heating Nitrogen is a critical process, which requires a heater of minimal Watt Density (WSI), less than 25 watts/square inch is required to heat Nitrogen safely. All Infinity CRES-SFC Heaters provide the necessary WSI to safely heat all forms of gases. Units which use
- AC Voltage Required: 120 to 480 volts
- kWatts: 0.25 to 10 kW
- Watt Density: 25 W/in²
- Flange or Thread Diameter: 0.25 to 0.5 inch
-
Supplier: UL Standards & Engagement
Description: heating furnaces, panel or cable type radiant heating equipment, electric boilers, baseboard heaters, air heaters, nor any other electric heating equipment or appliances which are covered in or as a part of separate, individual requirements. 1.3 Duct heaters
-
-
Supplier: Thermon, Inc
Description: Circulation heaters are the equivalent to tube and shell heat exchangers with the particular feature that the core bundle is manufactured with electric tubular heating elements. Circulation heaters are used in applications where a process stream needs to be heated
- Maximum Operating (Sheath) Temperature: 1,200 F
- AC Voltage Required: 660 volts
- Maximum Operating Temperature: 1,200 F
- Heater Type: Circulation Heater, Duct Heater, Tubular Heater
-
Supplier: Backer Hotwatt Inc.
Description: Features The Pure Flow Air Heater is designed for applications where clean air is necessary, as in laboratories and environmental testing areas. This heater is unique in supplying non-contaminated heated air. The stream of air is heated by passing over an enclosed heated surface
- Heating Capacity: 0.1 to 1.2 kW
- AC Voltage Required: 120 to 240 volts
- Maximum Air Temperature: 800 F
- Maximum Air Flow: 15 SCFM
-
Supplier: Berner International Corporation
Description: starts, directing a high velocity stream of hot air that heats the incoming cold air. Engineered for versatility the door heater can be mounted at any angle between horizontal and vertical to satisfy most applications. All heaters are factory assembled and shipped ready
- AC Voltage Required: 208 to 480 volts
- Maximum Air Flow: 6,500 to 7,900 SCFM
- Heater Type: Air Heater
- Features: Electric, Natural Gas / Propane
-
Supplier: Thermon, Inc
Description: Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil designs, duct
- AC Voltage Required: 120 to 600 volts
- Heater Type: Air Heater
- Features: Electric, Hot Water / Steam
- Phase: Single Phase
-
Supplier: OMEGA Engineering, Inc.
Description: The AHPF series heaters are used to heat low flows of air, gas, water, or aqueous solutions. Applications include those where clean air is necessary, as in laboratories and environmental testing areas. The stream of air is heated by passing over an enclosed heated surface rather
- AC Voltage Required: 120 to 240 volts
- Number of Elements: 1 #
- Height: 6 to 12 inch
- Duct Depth: 1.13 inch
-
Supplier: ASTM International
Description: Electric CurrentsThe arc-heated gas stream may have free electric currents that will contribute to measured experimental heat transfer rates. 1.3.5 Nonuniform Pressure ProfileA nonuniform pressure profile in the region of the stream at the point of the heat
-
Supplier: XeteX, Inc.
Description: perform on-the-fly calculations of mass flow rate. Heating was accomplished with a super-efficient double-pass heat exchanger, and an electric heater with modulating SCR controls. These components provided a supply air stream at the specified conditions and with the
- System: Heat Recovery Ventilator (ERV)
- Application: Residential
-
Supplier: ASTM International
Description: general operation of a Cone Calorimeter. PMMA should not be used with this standard as the heat release rate is too high. 1.3 The rate of heat release is determined by measurement of the oxygen consumption as determined by the oxygen concentration and the flow rate in the exhaust
-
Supplier: ASTM International
Description: general operation of a Cone Calorimeter. PMMA should not be used with this standard as the heat release rate is too high. 1.3 The rate of heat release is determined by measurement of the oxygen consumption as determined by the oxygen concentration and the flow rate in the exhaust
-
Supplier: SAE International
Description: electric resistance heaters. Real-world applications would use waste heat from the engine and scrubber process for acid evaporation and reduction. The system was evaluated with a fixed acid injection rate and various fuel flow rates to validate the thermal decomposition of
Find Suppliers by Category Top
Featured Products Top
-
The Cata-Dyne™ LH Line Heater prevents equipment freezing and possible hydrate formation during pressure reduction at natural gas regulating sites. The Cata-Dyne™ Line Heater heats the gas stream using infrared radiant heat transfer, eliminating the use of burners, glycol fluid and (read more)
Browse Explosion Proof Heaters Datasheets for Thermon, Inc -
Circulation heaters are the equivalent to tube and shell heat exchangers with the particular feature that the core bundle is manufactured with electric tubular heating elements. Circulation heaters are used in applications where a process stream needs to be heated to a finely controlled set (read more)
Browse Circulation Heaters Datasheets for Thermon, Inc -
cylinders as possible in order to heat and wrap from the hottest exhaust gases stream. Process of heating the sensor slows down the regulation process of the onboard controller because of the feedback. In addition, using the exhaust pipe as a signal ground requires sensor’s thread to be coated with (read more)
Browse Industrial Heaters Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil designs, duct (read more)
Browse Duct Heaters Datasheets for Thermon, Inc -
INDIRECT ELECTRIC TANK HEATER Indirect Electric Tank Heaters are designed to heat tank contents indirectly without the need to drain the tank for heater replacement. These heaters use open coil heater elements supported by high temperature ceramics. The elements slide inside of a (read more)
Browse Coil Heaters Datasheets for Gaumer Process -
Learn about electric heat and types of electric heaters as well as heat transfer, heat losses, basic heat equations, specific applications with example and watt density in a five page PDF. (read more)
Browse Electric Heaters Datasheets for Backer Hotwatt Inc. -
The simplest definition of an electric heater is any device that changes electrical energy into heat energy. But from that simple explanation, electric heaters explode into a myriad of types, sizes, applications, and designs depending upon what’s being heated, the degree of (read more)
Browse Electric Heaters Datasheets for Backer Hotwatt Inc. -
Indirect Electric Tank Heaters are designed to heat tank contents indirectly without the need to drain the tank for heater replacement. These heaters use open coil heater elements supported by high temperature ceramics. The elements slide inside of a pipe that is welded to the mating (read more)
Browse Explosion Proof Heaters Datasheets for Gaumer Process -
White paper: Role of electric heaters in chillers refrigeration heater Description: This white paper details how heat plays an essential role in the chilling process, making electric heaters an ideal solution for chilling applications. Download today! (read more)
Browse Electric Heaters Datasheets for WATTCO -
immersion heater is an electric heating apparatus consists of a bundle of tubular heating elements which are submerged in a tank or container to heat a liquid, such as water, oils of various viscosity, viscous materials, solvents, process solutions, liquidous chemicals, and (read more)
Browse Immersion Heaters Datasheets for Gaumer Process
More Information Top
-
Economy of a lastganggerechten regenerative industrial power supply
Increase of the cover with renewable current. The use of Power-to-Heat, by which in heat an electrical process heater current converts ●.
-
Thermal transfer
it carries • By ˙q∗ W = const for an increase of the temperature of the radiator by unchanged heat flux .
-
Thermal transfer
It carries W = const for an increase of the temperature of the radiator by unchanged heat flux .
-
Evaluation of 241-AZ tank farm supporting phase 1 privatization waste feed delivery
Upon exiting the HEME, the gas stream is heated by electric heaters to protect the downstream HEPA and HEGA filter banks.
-
Some hydrogen-control considerations for ice-condenser nuclear plants. [PWR]
The air stream is heated by electric heaters to about 1300°F, requiring 5 MW of electric input for the 50 units.
-
Thorium utilization program. Quarterly progress report for the period ending May 31, 1977
An electric heater will heat the stream to about 350°C to prepare for NO conversion.
-
Room climate technique
There are also extending data for room heating surfaces with the heat outputs and water currents of radiators (see the table D2.6-4).
-
Physics for engineers
For exercise Ü 3.5-1 Which 's convective heat flux , does a vertical plate radiator with the height h = 0,6 m and the width b give off = 1,2 m turbulently to the Umgebungs air when the uniform surface temperature…
-
Experimental and numerical studies of the lower flammability limit of mixtures of C1–C5 hydrocarbons with air
For this, the outer tubes of the burner were equipped with electric heaters which heated the blowing stream , and the latter, in turn, heated the inner tubes of the burner and the combustible mixture.
-
An Investigation of EGR Treatment on the Emission and Operating Characteristics of Modern Diesel Engines
The EGR stream was heated up with the electric heater (set at 0.75 kW) to enable catalytic reactions.
Indicates content that may require registration and/or purchase.