Supplier: Edgetech Instruments Inc.
Description: The Edgetech Instruments Model DPS3 is a heated dew point hygrometer that can measure dew points up to 95 °C (203°F) and as low as -35 °C (-31°F). This integrated system includes a microprocessor based electronics, a chilled mirror dew point sensor, a sample flow meter
- Dew Point Accuracy: 0.3600 +/-F
- Dew Point Range: -31 to 203 F
- Digital Outputs: Serial Interface
- Electrical Outputs: Analog Current, Analog Voltage, Switch or Relay
-
Supplier: TSI Incorporated
Description: Mount enclosure to a standard survey tripod equipped with a 5/8"-11 threaded stud Water trap that prevents precipitation from entering the instrument Field portable Secure method of deploying the DustTrak aerosol monitor and its accessories On the South Coast AQMD pre-approved list of
-
Supplier: TSI Incorporated
Description: , Solar Power System, Cloud Data Management System and Heated Inlet Sample Conditioner Lockable, secure enclosure 360° omni-directional sampling inlet specifically designed to sample efficiently in a broad range of wind conditions Water trap prevents precipitation from entering the
-
-
Supplier: RainWise, Inc.
Description: recorded in hours and minutes. Product Features The surface of the board is heated, so that after precipitation has ended, the surface of the sensor will quickly dry. This heated surface also prevents the system from showing a false indication from dew. The sensor is
- Device Classification: Sensor Only
- Electrical Heater (For winter environments): Yes
- Measures Rain/Snow Fall: Yes
- Output Options: Switch or Relay
-
Supplier: E+E Elektronik
Description: The EE211 is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding climate control. It features a heated humidity probe and an interchangeable temperature probe. Excellent performance of EE
- Digital Outputs: Serial Interface
- Display: Digital Readouts
- Electrical Outputs: Analog Current, Analog Voltage
- Form Factor: Sensor / Probe
-
Supplier: TSI Incorporated
Description: programmable data logging functions Aerosol concentration range 0.001 to 400 mg/m³ Environmental protected and tamper-proof with Environmental DustTrak Enclosure Cloud Data Management System for efficient remote monitoring Heated Inlet Sample Conditioner to reduce humidity effects On
- Instrument Type: Monitor
-
Supplier: TSI Incorporated
Description: Environmental protected and tamper-proof with Environmental DustTrak Enclosure Cloud Data Management System for efficient remote monitoring Heated Inlet Sample Conditioner to reduce humidity effects On the South Coast AQMD pre-approved list of instruments for Rule 1466
- Instrument Type: Monitor
-
Supplier: Technic, Inc.
Description: and connecting arm. The tank is heated by a 1,000 watt L-type de-rated heater (10 watts/sq. in.) with integral thermal overload protection, digital readout temperature control (+ .25%) and a low solution level shut-off. The module also features a filter system for continuous
- Applications: Semiconductor Wafers
- Form Factor: Wafer Probing System
- Measurement Capability: Electrical Test - Wafer Sort / Functional
-
Supplier: Wisconsin Oven Corporation
Description: SBH Series - Heavy Duty Small Batch Oven (SBH Series) Features: 27 Standard Sizes Two (2) temperature ratings, 650° F and 1,000° F Electrically Heated via tubular incoloy sheathed elements Airflow pressure switches on all blowers 20
- Application: Aging, Annealing, Heat Treating, Preheating, Other
- Atmosphere: Air / Oxidizing
- Capacity: 8 to 45 cubic feet
- Controller Type: Programmable
-
Supplier: Fluid Components Intl. (FCI)
Description: drying effect on the sensors that results in effective measurement in moist gas applications. The ST51 Series electronics are housed in rugged, IP67 rated enclosure with dual conduit ports in either NPT or M20 threading. The instrument comes standard with dual 4-20 mA, NAMUR NE43
- Velocity Flow Rate: 0.3000 to 400 ft/sec
- Electrical Output: Analog Current
- End Fittings: Compression
- Interface Options: Serial / Digital, Other
-
Supplier: Fluid Components Intl. (FCI)
Description: drying effect on the sensors that results in effective measurement in moist gas applications. The ST51 Series electronics are housed in rugged, IP67 rated enclosure with dual conduit ports in either NPT or M20 threading. The instrument comes standard with dual 4-20 mA, NAMUR NE43
- Velocity Flow Rate: 0.3000 to 400 ft/sec
- Electrical Output: Analog Current
- End Fittings: Compression
- Interface Options: Serial / Digital, Other
Find Suppliers by Category Top
Featured Products Top
-
system indicates proper operation of connected devices with varying voltages with consistent LED light brightness. Lights will not dim as output power varies in connected devices. Applications include: Heat tapes on pipes, gutters, and other surfaces like heated walkways (read more)
Browse Datasheets for Osborne Industries, Inc. -
Materials: Sheath material of the tubular heating element is determined by its corrosion resistance property and maximum operating temperature, choose from Incoloy or stainless steel. Terminal Housing or Enclosures: Based on different levels of ingress protection, choose (read more)
Browse Electric Heaters Datasheets for Gaumer Process -
Materials: Sheath material of the tubular heating element is determined by its corrosion resistance property and maximum operating temperature, choose from Incoloy or stainless steel. Terminal Housing or Enclosures: Based on different levels of ingress protection, choose (read more)
Browse Electric Heaters Datasheets for Gaumer Process -
-Thin Flexible Heaters is less than 0.22mm (0.0087 inches) and each typically weighs only 0.04 g/cm2 (0.009oz/in2). They are ideal heaters for applications with limited space such as defense electronics, aircraft, portable medical instruments, laboratory research, optical (read more)
Browse Flexible Heaters Datasheets for Pelonis Technologies, Inc. -
a heated NEMA 4X enclosure and includes an ULTIMA® X5000 gas monitor, pump, filter, calibration port and 3-way valve. Maintenance and calibration are simple procedures. If an obstruction occurs in the sample line, the unit provides (read more)
Browse Gas Instruments Datasheets for MSA Safety
Conduct Research Top
-
Understanding NFPA 86: Safety Ventilation and Continuous LFL Monitoring
oxidizers, and any other heated enclosure used for processing of materials and related equipment.
-
What is a Water to Air Heat Exchanger?
A water-to-air heat exchanger uses a steady supply of water to dissipate heat within an electrical enclosure or equipment cabinet. In this type of cooling system, water is circulated through a finned-tube coil. As heated air from the enclosure passes through the coil, the water absorbs the heat
-
What is an Air to Air Heat Exchanger?
element to remove excess heat. The cooled air is then routed back into the sealed enclosure while the heated air is forced out of the system.
-
The TURBO-DRYER
one revolution. The trays are contained in an enclosure in which heated air or gas is circulated.
-
Cladding Lack of Adherence in Facades of Buildings (.pdf)
of the consequent danger it poses to people and things. The research was based on the laboratory construction of two wall models simulating an enclosure type of facade. Those models were built with stone placated of 20 and 30 mm respectively, stuck to the brick factory with a mortar of glue cement
More Information Top
-
Training in the use of electrical heat tracing “a course outline”
Heated instrument enclosures are also available as prefabricated assemblies for winterization and elevated temperature maintenance.
-
Automating Trace Heating Designs from Plant 3-D Models
is currently the Electrical Design Supervisor for Jacobs * Heated instrument enclosures .
-
50 years of excellence in science and engineering at the Savannah River Site
Steam tracing was used for small lines, and generally electrical heating for instrument enclosures .
-
Operations and maintenance manual for the light duty utility arm (LDUA) at-tank instrument enclosure (ATIE) (LDUA system 4300)
The ATlE consists of a weatherproof (NEMA-4) instrument enclosure with heating and air conditioning; internal power distribution circuits for providing 120 VAC power to installed instrumentation; and miscellaneous instrument cabling as required to support interfacing between at-tank portions of the …
-
Ukpik: testbed for a miniaturized robotic astronomical observatory on a high Arctic mountain
built-in redundancies provide the best chance of obtaining data despite system failures, for example, an important implementation was the combination of a retractable weather-proof enclosure and heated instrument windows, as was the backup of wind power generation.
-
Oxygen Analysis and Control System addresses EPA’s MACT requirements
Other design features include climate controlled instrument enclosures and heat traced sample lines â features that extend the operating range of the system and, if necessary, allow it to be installed outdoors.
-
Oxygen analysis and control system addresses EPA's MACT requirements
Other design features include climate controlled instrument enclosures and heat traced sample linesâfeatures that extend the operating range of the system and, if necessary, allow it to be installed outdoors.
-
Flexible heat pipes for CCD cooling on the Advanced Camera for Surveys
The primary purpose of the CCD heat pipes is to transport the TEC generated heat to the instrument enclosure .
-
Quasidynamic calibration of stroboscopic scanning white light interferometer with a transfer standard
The halogen light also possibly causes more heating inside the instrument enclosure than the LED lighting.
-
Heated tubing: Prefabricated or field trace and insulate?
The independent mounting of the heated enclosure and the instrument tubing can create stress on this transition/connection.