Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Other
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online syngas analyzer Gasboard-3100 is a stationary analyzer with standard 19'' 3U rack enclosure, easy to be integrated inside industrial system. It is able to online continuously measure volume concentration of CO, CO2, CH4, H2 , O2 , CnHm, C2H2 , C2H4 simultaneously, and
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Fuji Electric Corp. of America
Description: Multigas analyser compact and light high performance multigas analyser. The ZSVS up to 4 gas components concentration measurement. Suited for gas monitoring in heat treatment furnaces, plant cultivation, and research-purpose chemical analysis. CO2 – CO – CH4 – O2
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2)
- Application: Confined Space Monitoring
-
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable natural gas analyzer Gasboard-3110P is a portable type analyzer and the best alternative of GC and MS that can be used for online measurement for natural gas composition and heating value second by second. It is widely used in various applications such as natural
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Handheld biogas analyzer Gasboard-3200Plus is handheld type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S and optional H2, CO gases, with high accuracy, stable performance and easy carrying features, widely used in anaerobic digestion biogas, waste
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online biogas analyzer Gasboard-3200 is a rack type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S with high accuracy, stable performance, can be easily integrated with biogas analysis system, widely used in anaerobic digestion biogas, waste water
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Self Calibration
-
Supplier: Teledyne Monitor Labs, Inc.
Description: The sensor-e® CO2 measures carbon dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy infrared light
- Number of Channels: 1
- Response Time: 10.00000000000002 seconds
- Operating Temperature: 41 to 104 F
- Application: Ambient Air Monitoring
-
Supplier: Teledyne Monitor Labs, Inc.
Description: The sensor-e® CO (TML30) measures carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass
- Number of Channels: 1
- Response Time: 10.00000000000002 seconds
- Operating Temperature: 41 to 104 F
- Application: Ambient Air Monitoring
-
Supplier: TOC Systems, Inc.
Description: Specific Interference-Free Gas Detection Dual-Wavelength Ratioing Compensates for Drift No Moving Parts Onboard Computer for Accuracy Sapphire Protected Optics Non-Corrosive, Non-ReflectiveHeated Sample Cell Prevents Condensation Detection Technique The NDIR CO 2 detector uses a solid-state,
- Gas Types: Carbon Dioxide (CO2)
- Instrument Type: Detector
- Mounting Type: Fixed
- Application: Process Gas
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Roscid Technologies
Description: The Model CO2Tracer is simple, accurate and very economic measurement of CO2 levels. One User specific measuring range The unit is offered in three different ranges: 0 -500ppm, 0-5%, 0-25% Sensor The CO2Tracer uses a special infrared cell to measure the CO2 concentration. The
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Current
-
Supplier: Siemens Process Instrumentation
Description: measurement of complex gas mixtures is also possible in many cases. This ensures measurements of low concentrations as well as low detection limits. Appropriate materials in the gas channel allow the analytical devices to be used even for measurements of gas mixtures with
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Methane (CH4) / Natural Gas, Nitric Oxide (NO), Sulfur Dioxide (SO2), Toxic Gas
- Application: Continuous Emissions Monitoring, Process Gas
-
Supplier: Siemens Process Instrumentation
Description: an innovative multi-component gas analyzer which can be equipped with the following sensors: IR detector for IR-active gases, UV photometer for UV-active gases, H2S sensor (electrochemical), O2 sensor (electrochemical or paramagnetic), and used accordingly in numerous applications and
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2), Sulfur Hexafluoride (SF6), Toxic Gas
-
Supplier: Siemens Analytical Products
Description: infrared active components in a single unit, the ULTRAMAT 6F up to two infrared active components. The use of optical couplers and the optional use of optical filters to increase the selectivity mean that, in many cases, the analyzers can be used for measurements even in complex
- Number of Channels: 2
- Operating Temperature: -22 to 158 F
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 5000 Series Portable Flue Gas analyzer has been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The 5000 uses customer replaceable sensors which respond quickly to the O2, CO2, SO2, CO,
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova Model 7200-1-F1 flue gas analyzer is specifically designed for use on the flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate
- Response Time: 20 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 5 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4
- Response Time: 15 seconds
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below.
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: Emerson Automation Solutions – Rosemount
Description: measurement capability Robust all solid state See the Features & Benefits tab below for more details. Cascade’s CT4000 system monitors in real time NO, NO2, SO2, CH4, H2O, CO and CO2 levels in ambient environments of up to 70°C (158°F) and gas temperatures of 190°C (374°F).
- Operating Temperature: -4 to 158 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Process Sensing Technologies USA
Description: Environmental protection rating to IP65 Optional inbuilt audible and visual alarms Programmable O2, CO2 and CO alarms output Two isolated 4-20Ma analogue outputs Zirconia oxygen sensor Infrared CO2 sensor Electrochemical CO sensor
- Operating Humidity: 15 to 95 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Gas Types: Oxygen (O2)
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using
- Number of Channels: 4
- Response Time: 30 seconds
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Continuous gas analysis for process and emission monitoring applications, combining TDL and QCL technologies to measure up to twelve components simultaneously down to low ppm. Improve Measurement Control with Fast, Reliable, Real-time Data Quantum Cascade Laser (QCL) multi-component
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Measurement Type: %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NxOx), Oxygen (O2), Sulfur Dioxide (SO2)
-
Supplier: ABB Measurement & Analytics
Description: This instrument can easily be integrated into a continuous emission monitoring solution. Based on Fourier-transform infrared (FTIR) technology, the MBGAS-3000 Analyzer provides exceptional stability, sensitivity, and photometric accuracy. Based on hot/wet sample extraction. No sample
- Operating Temperature: 41 to 104 F
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrocarbons, Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Nitrogen Dioxide (NO2), Sulfur Dioxide (SO2), Water Vapor
- Instrument Type: Analyzer
- Application: Continuous Emissions Monitoring
-
Supplier: ABB Measurement & Analytics
Description: technology Intuitiv operation via five buttons UV photometer Infrared photometer Paramagnetic oxygen analyzer Electrochemical oxygen sensor Thermal conductivity analyzer Trace oxygen analyzer Flame Ionization Detector Extensive self-diagnosis functions Internal QAL3
- Operating Temperature: 41 to 122 F
- Operating Humidity: 50 %
- Response Time: 2.5 seconds
- Measurement Type: %Volume, Trace
-
Supplier: MIDAC Corporation
Description: For years, MIDAC has provided customized solutions for demanding gas analysis applications. This accumulated experience uniquely qualifies us to provide "total solutions" for virtually any gas analysis need - from environmental to industrial process applications. The versatility of
-
Supplier: Linseis Inc.
Description: Possible Techniques: FTIR: Fourier Transform Infrared Spectroscopy: Measurement of basic and trace gas components until ppm range (for example H2O, CO2, CO, H2S...). Polar Molecules are necessary. Raman-Spectroscopy: Measurement of basic gas components. Also not polar
- Features: Fourier Transform (FT-Raman)
-
Supplier: Analytical Systems Int’l. Keco
Description: The petrochemical, gas processing, and gas pipeline industry has required an accurate and dependable, low maintenance and cost-effective CO2 analyzer for quality and process control purposes. Analytical Systems International has met these requirements with their proven
- Dissolved CO2 Range: 1,000,000 ppm
- Operating Temperature: 32 to 122 F
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Features and Functionality: Built-in or Self-calibration
-
Supplier: LI-COR Biosciences
Description: The LI-820 CO2 Analyzer is a low maintenance, economical gas analyzer designed for continuous monitoring applications. It is an absolute, non-dispersive infrared (NDIR) gas analyzer based upon a single path, dual wavelength, thermostatically
-
Supplier: COSA Xentaur Corporation
Description: The ZSS is a Highly Efficient Ammonia (NH3), Hydrochloric Acid (HCl), Moisture, Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) and Methane (CH4) Optical Gas Analyzer For Stack Gas Applications. COSA ZSS The ZSS uses a non-dispersive infrared absorbance
- Response Time: 1.999999999999998 seconds
- Operating Temperature: -4 to 131 F
- Operating Humidity: 0 to 90 %
- Gas Types: Ammonia (NH3), Hydrogen Chloride (HCl)
-
Supplier: GasLab
Description: logging is desired. Using an accurate optical chemical sensors to measure oxygen and an infrared NDIR sensor to measure carbon dioxide, the TecPen MAP Oxygen and CO2 Headspace Gas Analyzers are designed to last for years. Features Accurate optochemical oxygen sensor
-
Supplier: LI-COR Biosciences
Description: The LI-840A CO2/H2O Analyzer is a low maintenance, economical gas analyzer designed for continuous monitoring applications. It is an absolute, non-dispersive infrared (NDIR) gas analyzer based upon a single path, dual wavelength, thermostatically
-
Supplier: LI-COR Biosciences
Description: The LI-7500A is a high speed, high precision, non-dispersive infrared gas analyzer that accurately measures densities of carbon dioxide and water vapor in-situ. With the eddy covariance technique, these data are used in conjunction with sonic anemometer wind speed to determine
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova Model 7900P Series Heat Treat analyzers utilize a three channel high stability infrared detector for the simultaneous measurement of CO, CO2, and CH4 in exothermic or endothermic gas mixtures. In addition, the analyzer can be supplied with a fully
- Response Time: 20 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: ABB Measurement & Analytics
Description: (FID) technology and oxygen measurement. The high resolution FTIR spectrometer provides selective measurement of infrared active gas molecules with high sensitivity and stability. The multi-component analyzer system ACF5000 offers: Simultaneous measurement of up to 15 gas
- Response Time: 400 seconds
- Operating Temperature: 41 to 86 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
Find Suppliers by Category Top
Featured Products Top
-
The Palm CO Analyzer is a compact, portable instrument designed to detect carbon monoxide contamination in breathing air and compressed gas systems. It provides fast, reliable CO measurement to help prevent exposure to dangerous carbon monoxide levels (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
fuel analysis is a necessity. It fulfills the requirements of ASTM D 6728, Standard Test Method for Determination of Contaminants in Gas Turbine and Diesel Engine Fuel by Rotating Disc Electrode Atomic Emission Spectrometry. The SpectrOil M/F-W is a compact, rugged and easy to use (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
The Chemgard Photoacoustic Infrared Gas Monitor with IR sensing technology provides precise, low-cost, high-performance monitoring for one hundred different industrial gases! These gases include 59 standard gases such hydrocarbons, solvents, alcohols, CO2, and CO to name a few (read more)
Browse Gas Instruments Datasheets for MSA Safety -
Measurement: Follows ASTM D8092 (New), using 60 microliters of oil without sample preparation. The viscosity test duration ranges from 2 seconds to 6 minutes, depending on the sample. The test is temperature-controlled at 40°C and requires no solvents or chemicals. Elemental (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
industry expertise and relationships that have cemented CO2Meter as a true "go-to-source" for customers and partners. Their technologies encompass a wide range of product categories from fixed gas detectors, portable gas analyzers, and gas controllers that are installed and used widespread across the (read more)
Browse Gas Instruments Datasheets for CO2Meter.com -
High-Performance Infrared CO? Sensors for Diverse Applications Dynament offers an extensive selection of carbon dioxide sensors based on non-dispersive infrared (NDIR) technology, delivering accurate CO? detection across a broad measurement range, from 500 ppm to 100 (read more)
Browse Gas Sensors Datasheets for Dynament -
Dynament’s advanced dual-gas infrared sensors are engineered to measure methane (CH?) and carbon dioxide (CO?) simultaneously within a single compact sensor unit—while consuming the power of just one standard infrared sensor. This efficient design helps extend battery life (read more)
Browse Gas Sensors Datasheets for Dynament -
CO2Meter Inc., a worldwide leader in gas detection and safety monitoring, released its new portable CO2 welding gas analyzer that verifies correct CO2 concentrations in welding gas mixes. The highly anticipated CM-1650 measures mixed cylinder gas or blended gas at a mixer to ensure the (read more)
Browse Data Loggers and Data Recorders Datasheets for CO2Meter.com -
wide range of gases, including R32, R454B, R454C, R290, and R744 (CO?). Based on proven non-dispersive infrared (NDIR) sensing technology, Dynament sensors deliver stable performance, long operating life, and high measurement accuracy. The platform has been (read more)
Browse Gas Sensors Datasheets for Dynament -
The Platinum Series Hydrocarbon Sensor is a fully integrated gas-sensing platform designed for accurate measurement of methane and propane across a wide range of industrial applications. Combining optics, electronics, and embedded firmware within a single package, the sensor delivers a (read more)
Browse Gas Sensors Datasheets for Dynament
More Information Top
-
A whole‐tree chamber system for examining tree‐level physiological responses of field‐grown trees to environmental variation and climate change
An infrared CO2 gas anal- yser in each chamber (SBA-1, PP Systems, Hitchin, UK) was used to measure chamber [CO2] at 90 s intervals.
-
Consequences of Incomplete Surface Energy Balance Closure for CO2 Fluxes from Open-Path CO2 /H2 O Infrared Gas Analysers
Twine et al. (2000) provide experimental evidence suggesting that the magnitude of CO2 fluxes measured using closed-path H2O/ CO2 infrared gas analy- sers (IRGA) may be underestimated by the same factor as latent heat fluxes.
-
Research on desorption and regeneration of simulated decarbonization solution in the process of CO2 capture using ammonia method
Infra- red CO2 gas analyzer (manufactured by Angwei Co., Shen- zhen, China) with the measurement range of 0 to 100% (volume percent) and precision within ±3% was used.
-
Belowground carbon input and translocation potential of fodder radish cover-crop
Additionally, a chamber CO2 concentra- tion monitoring system was developed by connecting a Licor-800 infrared CO2 gas analyzer via teflon tubes (Ø=0.6 mm) to the 14 CO2 assimilation chamber throughout the labelling period.
-
An Alternative Approach for CO2 Flux Correction Caused by Heat and Water Vapour Transfer
Energy and CO2 fluxes are commonly measured above plant canopies using an eddy covariance system that consists of a three-dimensional sonic anemometer and an H2O/ CO2 infrared gas analyzer .
-
Comparison of Overall Gas‐Phase Mass Transfer Coefficient for CO 2 Absorption between Tertiary Amines in a Randomly Packed Column
…installed and played a crucial role in conducting the absorption experiment, including an air compressor, a CO2 cylinder, two gas mass flow meters, a constant liquid-flow pump, a thermostatic water bath, an infra- red CO2 gas analyzer , a probe of digital…
-
In situ assessment of the velocity of carbon transfer by tracing 13 C in trunk CO 2 efflux after pulse labelling: variations among tree species and seasons
13 CO2 infrared gas analyser (S710; SICK⁄MAIHAK, Reute, Germany; accuracy 5%) calibrated by diluting pure CO2 from gas tanks having different 13 C⁄12 CO2 (10, 50 and 100%) in a stream of CO2 free air using mass flow controllers.
-
Carbon dioxide flux in the centre of Łódź, Poland—analysis of a 2‐year eddy covariance measurement data set
The measurement system includes a Kipp and Zonen's (Delft, Holland) CNR1 net radiometer, RMYoung (Traverse City, Michigamn, USA) 81000 sonic anemometer and Li‐cor (Lincoln, Nebraska, USA) 7500 open path H2O/ CO2 infrared gas analyser .
-
BENTHIC METABOLISM ON A SHELTERED ROCKY SHORE: ROLE OF THE CANOPY IN THE CARBON BUDGET
Changes in CO2 mole fraction (ppm) in air upon rocky substratum were measured with an infrared CO2 gas analyzer (LiCor Li-800; LI-COR Inc., Lincoln, NE, USA).
-
Impact of severe dry season on net ecosystem exchange in the Neotropical rainforest of French Guiana
The system measured the in- crease in CO2 concentration in the headspace by circulat- ing the air through Synflex 1300 tubing to a closed-path CO2 infrared gas analyser (Li840; LI-COR Inc.).
Indicates content that may require registration and/or purchase.