-
Supplier: Pope Scientific, Inc.
Description: Efficient thermal separation with minimum product decomposition and maximum product quality; these are results you can expect using Wiped Film - Short Path process for distillation, evaporaton, concentration, separation, purification or deodorization. Performance is superior to flash
- Application: Food Processing, Pharmaceutical Processing, Research and Development, Solvent Recovery, Other
- Heating / Power Source: Electric
- Operation: Laboratory
- Process: Vacuum Distillation, Wiped Film
-
Supplier: Pope Scientific, Inc.
Description: Efficient thermal separation with minimum product decomposition and maximum product quality; these are results you can expect using Wiped Film - Short Path process for distillation, evaporaton, concentration, separation, purification or deodorization. Performance is superior to flash
- Application: Food Processing, Pharmaceutical Processing, Research and Development, Solvent Recovery, Other
- Heating / Power Source: Electric
- Operation: Laboratory
- Process: Vacuum Distillation, Wiped Film
-
Supplier: Pope Scientific, Inc.
Description: Efficient thermal separation with minimum product decomposition and maximum product quality; these are results you can expect using Wiped Film - Short Path process for distillation, evaporaton, concentration, separation, purification or deodorization. Performance is superior to flash
- Application: Food Processing, Pharmaceutical Processing, Research and Development, Solvent Recovery, Other
- Heating / Power Source: Electric
- Operation: Pilot, Laboratory
- Process: Vacuum Distillation, Wiped Film
-
-
Supplier: Labconco Corporation
Description: CentriVap Centrifugal Vacuum Concentrators use a combination of centrifugal force, vacuum and heat to speed evaporation of multiple small samples. They offer maximum throughput required by biology, microbiology, biochemistry, pharmaceutical research and analytical chemistry laboratories. As
- Application: Chemical Processing, Pharmaceutical Processing, Other
- Display and Interface: Yes
- Heating / Power Source: Electric
- Operating Temperature: -4 to 100 C
-
Supplier: Labconco Corporation
Description: CentriVap Centrifugal Vacuum Concentrators use a combination of centrifugal force, vacuum and heat to speed evaporation of multiple small samples. They offer maximum throughput required by biology, microbiology, biochemistry, pharmaceutical research and analytical chemistry laboratories. As
- Application: Chemical Processing, Pharmaceutical Processing, Other
- Display and Interface: Yes
- Heating / Power Source: Electric
- Operating Temperature: 1.0000 to 100 C
-
Supplier: Labconco Corporation
Description: The CentriVap Benchtop Vacuum Concentrator with acrylic lid is a compact evaporation system that utilizes centrifugal force, vacuum and heat to speed evaporation of multiple biological or analytical samples. Exclusive features include: brushed, stainless steel and glacier white, epoxy
- Application: Chemical Processing, Other
- Display and Interface: Yes
- Heating / Power Source: Electric
- Operation: Laboratory
-
Supplier: Labconco Corporation
Description: The Refrigerated CentriVap Benchtop Vacuum Concentrator is a compact evaporation system that utilizes centrifugal force, vacuum and heat to speed evaporation of temperature sensitive biological or analytical samples. Exclusive features include: refrigeration system that cools to -4° C
- Application: Chemical Processing, Pharmaceutical Processing, Other
- Display and Interface: Yes
- Heating / Power Source: Electric
- Operating Temperature: -4 to 100 C
-
Supplier: Bronkhorst USA
Description: General The CEM-System (Controlled Evaporation and Mixing) is an innovative Liquid Delivery System (LDS) that can be applied for atmospheric or vacuum processes. The vapour generation system consists of a liquid flow controller, an MFC for carrier gas and a temperature controlled mixing
- Application: Coating / Etching, Research and Development, Semiconductor Manufacturing, Other
- Heating / Power Source: Electric
- Operating Temperature: 20 to 200 C
- Operation: Production, Laboratory
-
Supplier: Bronkhorst USA
Description: Based on the CEM-technology, Bronkhorst designed a new series of Vapor Delivery Modules. These compact sub-systems incorporate the components of the CEM-System and more! Besides gas and liquid flow controllers and the temperature controlled evaporator, the VDM-Series feature integrated power
- Application: Chemical Processing, Coating / Etching, Research and Development, Semiconductor Manufacturing, Other
- Display and Interface: Yes
- Evaporation Rate: 0.7920 to 158 GPH
- Heating / Power Source: Electric
-
Supplier: Pope Scientific, Inc.
Description: Efficient thermal separation with minimum product decomposition and maximum product quality; these are results you can expect using Wiped Film - Short Path process for distillation, evaporaton, concentration, separation, purification or deodorization. Performance is superior to flash
- Application: Food Processing, Pharmaceutical Processing, Research and Development, Solvent Recovery, Other
- Heating / Power Source: Electric
- Operating Temperature: -3.89 to 177 C
- Operation: Production
-
Supplier: Glas-Col, LLC
Description: Fine needle valve controls the total flow to the equalizer manifold that gives equal gas flow to each well. Each well has consistant evaporation. Needle height is easliy adjustable to enable most sizes and capacities of microplates.
- Application: Research and Development
- Display and Interface: Yes
- Heating / Power Source: Other
- Operation: Laboratory
-
Supplier: Glas-Col, LLC
Description: This system is designed to rapidly evaporate/concentrat e solvents by both heating the sample bottom and the incoming nitrogen. Each position is furnished with an individual orifice for the best possible delivery of gas. The pulsing feature allows a film of solvent to be thrown on the
- Application: Research and Development
- Display and Interface: Yes
- Heating / Power Source: Other
- Operation: Laboratory
-
Supplier: KNF Neuberger, Inc.
Description: The RC 600 Rotary Evaporator provides a user-friendly interface while saving valuable lab bench space with its small footprint. The electric lift allows for easy and safe operation. Among its many features are simple flask exchange, cordless bath and choice of a recirculating condensor
- Application: Distillation, Research and Development, Other
- Operation: Laboratory
- Process: Rotary
-
Supplier: Glas-Col, LLC
Description: Only the insert is heated on these systems. This promotes heat exchange and speeds evaporation.
- Application: Research and Development
- Display and Interface: Yes
- Heating / Power Source: Other
- Operation: Laboratory
-
Supplier: Glas-Col, LLC
Description: . The pulsing feature allows a film of solvent to be thrown on the sidewall; then the vortex collapses. Next the vortex again is created and the process continues until the concentration level is achieved providing the quickest method of evaporation. Pulse mode with selectable settings
- Application: Research and Development
- Display and Interface: Yes
- Heating / Power Source: Other
- Operation: Laboratory
Find Suppliers by Category Top
More Information Top
-
LabX.com New and Used Laboratory Equipment and Scientific Instruments
Used Pfaudler Wiped Film Evaporator System Setra EL-2000S Precision Balance Digital Lab Scale .
-
Sodium-Bearing Waste Treatment, Applied Technology Plan
… has poor permeability making it difficult to filter, as was indicated by analytical lab tests on WM … … The co-processing of solids with liquids during evaporation is critical if the evaporator option is to … However solids can hinder traditional evaporation via fouling and subsequent degradation in heat transfer coefficients, and therefore special evaporators, such as wiped film evaporators will be studied after liter glass scale tests and in-can tests are completed to define operating parameters.
-
Fluid Dynamics Assessment of the VPCAR Water Recovery System in Partial and Microgravity
Experiments are beng conducted in normal gravity in the lab , as well as partial and microgravity in … The VPCAR contains a Wiped - Film Rotating Disk (WFRD) with an evaporating film of wastewater on one side of a flat disk and a condensing film of clean water on the other to recover the latent heat of vaporization. … to ensure successful partial and microgravity system operation as well as develop accurate scaling laws to size … … gravitational concern is the design of the wiper used to distribute the contaminated water over the evaporator .
-
RESEARCH ON CARBON PRODUCTS FROM COAL USING AN EXTRACTIVE PROCESS
A Pfaudler Wiping Thin Film Evaporator was purchased for this research project. The CEPU has been described as being too big to be a laboratory- scale unit but too … Therefore, the Rotovap and drying oven from the lab had to be used.
-
Sodium-bearing Waste Treatment Technology Evaluation Report
In lab scale testing for WM-189 simulant, it was observed that the product would set up “rock hard” when concentrated above 59.8 wt% (Kirkham, 2003). … balances assume magnesium nitrate solidifies as dihydrate unless this results in an endpoint evaporator temperature greater than … The DF for the evaporator was specified as 10,000 based on PEWE performance, and consistent with that determined for most feed components achieved in wiped film evaporator tests conducted at Oak Ridge .
-
Polyethylene encapsulation of mixed wastes: Scale-up feasibility
Stability under anticipated storage, and disposal conditions and compliance with applicable hazardous waste regulations were demonstrated through a series, of lab - scale waste form, performance tests, Full_scale demonstration of this process using actual or surrogate waste is currently planned. of wastes in polyethylene, including batch heating vessels, wiped film . evaporators , and screw extruders.
-
Assessment of the Technical Readiness of the Vapor Phase Catalytic Ammonia Removal Process
3) These initial programs resulted in the development of lab - scale glassware configurations. The core of the process is the Wiped - Film Rotating-Disk evaporator (WFRD).
-
Influence of KOH solution on the tensile strength and chemical stability of carbon fiber‐reinforced epoxy resin composites
… utilization of reinforced epoxy resin composites as cell frame material for a pilot scale electrolysis cell employing … … potassium hydroxide aqueous solution was pre- pared by dissolving 224.4 g of lab grade KOH granular … The mixture was degassed un- der vacuum using a rotary film evaporator for 30 min. … a release agent (Frekote 44-NC) and the faces of the mold were wiped with a silicone …
-
Technical area status report for low-level mixed waste final waste forms. Volume 2, Appendices
Japan Atomic Energy Research Institute Low density polyethyleneis melted at 160°C and mixed with waste to form homogeneous solid, using batch wiped film stirrer. Low-densitypolyethylene Powdered ion exchangeresins 40- 50 wt% powdered ion exchange resins Experimental ( lab - scale ), limited application at time of publication ASTM D-6952 test. … Free Liquids: Chemical Durability: CompositionalFlexibility: Gas Generation: RCRA Compliance: Conclusions: Incorporation of an Evaporator Concentrate on Polyethylenefor .
-
Polyethylene encapsulatin of nitrate salt wastes: Waste form stability, process scale-up, and economics
Several processing techniques were considered for encapsulation ofwastes inpolyethylene, including batch heating vessels, wiped film evaporators , and screw extruders. … for encapsulation of nitrate salt waste in polyethylene was performed using a laboratory- scale plastics extruder (32 … The lab -scale extruder was operated with an output rate between 1 kg/hr (2.2 lbs/hr) and …
Indicates content that may require registration and/or purchase.