-
Supplier: International Thermal Systems LLC.
Description: and dB testing with certification. In-house laboratory featuring a custom test oven and other related thermal equipment. Factory direct installation services. Conduct an energy efficiency analysis on the existing thermal processing equipment. Upgrade for all makes and models of thermal
- Temperature Range: 1,200 F
- Atmosphere: Air / Oxidizing, Inert
- Heat Source: Combustion, Electric / Resistance, Natural Gas, Oil, Propane
- External: Continuous (Convey, Shuttle)
-
Description: Describes a laboratory vibration mill procedure for the determination of the grain stability of calcined coke for the manufacture of carbon products used in the manufacture of aluminium.
-
Supplier: CSA Group
Description: Describes a laboratory vibration mill procedure for the determination of the grain stability of calcined coke for the manufacture of carbon products used in the manufacture of aluminium.
-
-
Supplier: Accuris
Description: Methods of Sampling and Test for Carbonaceous Materials for Use in Aluminium Manufacture; Part 2: Electrode Coke; Section 2.15: Determination of Grain Stability of Calcined Coke Using a Laboratory Vibration Mill
-
Supplier: Komline
Description: reactor, heat treater, calciner, humidifier, agglomerator, sublimer, roaster, in combination if required. Environmentally sealed, and explosion-proof models The self-cleaning wiping action often eliminates the need for manual cleaning at product changeovers Easy startup and operation on
- Operating Temperature: 1,200 F
- Secondary Capability: Agglomeration / Granulation, Cooling / Freezing, Moisturizing / Humidifying
- Applications / Materials Handled: Bulk Materials / Briquettes, Chemicals / Fertilizers, Foods / Grains, Free Flowing Powders / Granules, Mining / Ores / Minerals, Pharmaceutical, Solutions / Liquids
- Equipment Type: Continuous Tray / Turbo Tray Dryer
-
Supplier: ASTM International
Description: 1.1 This test method covers a laboratory vibration mill method for the determination of the grain stability of calcined coke for the manufacture of carbon products used in the smelting of aluminum. Calcined coke with poor mechanical strength may become degraded during mixing. Poor grain
-
Supplier: Carbolite Gero Limited
Description: Laboratory scale rotary batch furnace provides agitation of powdered solids under controlled atmosphere and temperature environment. Maximum operating temperature of 1100°C. Designed to simulate larger industrial rotary calcining processes in a laboratory size furnace. Continuous
- Process Temperature: 0 to 1,100 C
- Width / Tube O.D.: 150.00000000000003 mm
- Length (Chamber / Tube): 200 mm
- Atmosphere: Air / Oxidizing, Inert
-
Supplier: ASTM International
Description: 1.1 This test method covers the analysis for the commonly determined trace metals (aluminum, calcium, iron, nickel, silicon, sodium, and vanadium) in laboratory analysis samples of raw and calcined petroleum coke by atomic absorption spectroscopy. 1.2 The elemental concentration ranges for
-
Supplier: Komline
Description: reactor, heat treater, calciner, humidifier, agglomerator, sublimer, roaster, in combination if required. Environmentally sealed, and explosion-proof models The self-cleaning wiping action often eliminates the need for manual cleaning at product changeovers Easy startup and operation on
-
Supplier: International Thermal Systems LLC.
Description: for remote diagnostic and communication capabilities. UL or CE certified control panels or complete systems. PE certifications to meet a variety of client or government specific requirements. Advance thermal, vibratory, and dB testing with certification. In-house laboratory featuring a custom
- Process Temperature: 1,371.111111111111 C
- Atmosphere: Air / Oxidizing, Inert
- Application: Annealing, Curing, Preheating
- Configuration: Box
-
Supplier: International Thermal Systems LLC.
Description: with Ethernet for remote diagnostic and communication capabilities. UL or CE certified control panels or complete systems. PE certifications to meet a variety of client or government specific requirements. Advance thermal, vibratory, and dB testing with certification. In-house laboratory
- Process Temperature: 1,371.111111111111 C
- Atmosphere: Air / Oxidizing, Inert
- Application: Annealing
- Heat Source: Combustion, Electric / Resistance, Natural Gas, Oil, Other Fuel, Propane
-
Supplier: Harper International Corporation
Description: proper processing conditions and for defining suitable materials of construction. It is often the case that the properties of the material being tested can change as a function of temperature and time. Small tests enable proper equipment design to deal with these changes. Harper’s laboratory
- Process Temperature: 600 to 1,800 C
- Application: Drying, Firing / Sintering
- Features: Other
- Heat Source: RF / Microwave / Dielectric
Find Suppliers by Category Top
More Information Top
-
Plutonium Finishing Plant (PFP) Final Safety Analysis Report (FSAR) [SEC 1 THRU 11]
Air compressor for Laboratory Calciner .
-
Test Plan for Radioactive Testing of a Vertical Direct Denitration Calciner
… SD-CP-OSR-0 IO,Plutonium Finishing Plant Operational Safety Requirements LimitingCondition for Operation (LCO) 3.2.3 has been revised to include the requirement for the existing seismic shutdown system to also shut down the laboratory calciner in the event of …
-
Idaho Chemical programs annual technical report, fiscal year 1975
The effect on fluoride volatility of adding aluminum will be determined by pilot plant calciner runs using in-bed combustion, prior to use in the WCF; in the past static, laboratory calciners simulating indirectly heated calciners have given unreliable results on fluoride …
-
Letter report seismic shutdown system failure mode and effect analysis
In addition, an appendix has been added that to the document that contains an analysis of the expected seismic response of some of the laboratory calciner non-seismically rated valves.
-
CREATE A CONSORTIUM AND DEVELOP PREMIUM CARBON PRODUCTS FROM COAL
The green coke was calcined in a laboratory calciner to about 1300°Cto remove volatiles, increase density, and promote crystallinity.
-
Idaho Chemical Programs annual technical report, fiscal year 1972
However, the absolute amount of ruthenium volatilized in the WCF at 400 versus 500^C cannot be predicted by the small laboratory calciner used in these studies because of many differences between the operation of the two calciners.
-
CSER 99-001: PFP LAB Dentirating calciner
This is based on experience with the PFP laboratory calciner , where normal product tap density was found to be 4.0 to 4.3 g Pu/cm3.
-
CSER 97-004: PFP production denitration calciner system
This is based on experience with the PFP laboratory calciner , where normal product tap density was found to be 4.0 to 4.3 g Pdcm3.
-
Hanford Atomic Products Operation monthly report for May 1956
attempt to d_plicate results obtained in the S-inch laboratory calciner .
-
Chemical Processing Department monthly report for January 1964
d. -U03 Process Improvement UNH Calciner - The laboratory calciner was operated f o r approximately 50 hours during t h e month on both 100 per cent and 60 per cent UNH at temperatures near 300 C. gradually being resolvedo essentially complete …
Indicates content that may require registration and/or purchase.