Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ABB Measurement & Analytics
Description: analyzers to make true measurements at data rates of 20 Hz makes them excellent choices for eddy covariance flux measurements and for mobile leak (e.g., natural gas, coal seam gas, coal bed methane) detection. The analyzer uses ABB’s patented Off-axis ICOS
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
- Number of Gases Monitored: Multi Gas
-
Supplier: ABB Measurement & Analytics
Description: LGR’s Methane/Acetylene Analyzer is the world’s most advanced instrument for simultaneous measurements of methane, acetylene and water vapor. Quite simply, no other analyzer provides higher performance. Measurement of acetylene can be extremely useful in tracer studies of
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: ABB Measurement & Analytics
Description: LGR’s new ground-breaking Ultra-Portable Methane Analyzer (UMA) reports measurements of methane and water vapor simultaneously in a package that is compact and crushproof. Small enough to be carried on-board aircraft (TSA approved size) and requiring only 60 watts, the UMA
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
-
Supplier: ABB Measurement & Analytics
Description: LGR's Greenhouse Gas Analyzer (model GGA-24EP) is the world's most advanced instrument for simultaneous measurements of methane (CH4), carbon dioxide (CO2) and water vapor (H2O). Quite simply, no other analyzer provides higher performance. (For details, please see:
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: Accuris
Description: Continuous analyzers for methane in emission gas
-
Supplier: Owlstone Inc.
Description: Lonestar is a portable gas analyzer that can detect a broad range of analytes at part per billion concentrations, with high selectivity in just a few seconds.
- Operating Temperature: 41 to 104 F
- Operating Humidity: 5 to 90 %
- Response Time: 1.000000000000002 seconds
- Measurement Type: %Volume, Signature or Spectra, Trace
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable natural gas analyzer Gasboard-3110P is a portable type analyzer and the best alternative of GC and MS that can be used for online measurement for natural gas composition and heating value second by second. It is widely used in various applications such as natural
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Siemens Process Instrumentation
Description: measurement of complex gas mixtures is also possible in many cases. This ensures measurements of low concentrations as well as low detection limits. Appropriate materials in the gas channel allow the analytical devices to be used even for measurements of gas mixtures with
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Methane (CH4) / Natural Gas, Nitric Oxide (NO), Sulfur Dioxide (SO2), Toxic Gas
- Application: Continuous Emissions Monitoring, Process Gas
-
Supplier: Siemens Process Instrumentation
Description: an innovative multi-component gas analyzer which can be equipped with the following sensors: IR detector for IR-active gases, UV photometer for UV-active gases, H2S sensor (electrochemical), O2 sensor (electrochemical or paramagnetic), and used accordingly in numerous applications and
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2), Sulfur Hexafluoride (SF6), Toxic Gas
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Laser raman gas analyze?r LRGA-6000 is an advanced equipment that can online measure all the gas composition of most fuel gases, including biogas, syngas, natural gas, producer gas and so on. And with the unique advantages of no consumables, higher accuracy, long
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Oxygen (O2), Water Vapor
-
Supplier: Siemens Analytical Products
Description: The "Combi-Analyzer" ULTRAMAT/OXYMAT 6 combines the features of the ULTRAMAT 6 and OXYMAT 6 in one analyzer in a 19" rack design. Most frequently used for demanding applications, the ULTRAMAT 6 must meet high standards with regard to reliability and measuring quality. This is
- Operating Temperature: 41 to 113 F
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Sulfur Dioxide (SO2)
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
-
Supplier: Fuji Electric Corp. of America
Description: Optimization of combustion efficiency and compliance with environmental standards. Ideal for combustion control in boilers, incinerators, and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy. This oxygen analyzer is used to continuously measure oxygen concentration in the
- Response Time: 10 seconds
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable syngas analyzer Gasboard-3100P is a portable type analyzer used for syngas composition analysis. It is widely used in various applications such as biomass gasification, coal gasification, waste to energy, RDF, methane conversion, blast furnace top gas, coke
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Fuji Electric Corp. of America
Description: Insertion type offers high-speed measurement. Long-term stability and low maintenance. ZSS Laser Gas Analysers for : waste incinerators, district heating and industrial boilers, chemical plant. NH3 – HCI – CO – O2 – CO2 – CH4
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrogen Chloride (HCl), Methane (CH4) / Natural Gas, Oxygen (O2)
- Application: Confined Space Monitoring
- Mounting Type: Fixed
-
Gas Chromatographs - Sensor Gas Chromatograph - Hydrogen/Carbon Monoxide/Methane Analyzer -- SGHA-P2Supplier: FIS Inc.
Description: Sensor Gas Chromatograph (SGC) uses a highly sensitive semiconductor gas sensor as a gas detector. The original built-in column is small, enabling the sample gases to be very sensitive and quick separation.
- Oven Temperature Range: 50 to 86 F
- Operating Temperature: 50 to 86 F
- User Interface: Analog Front Panel
- Remote Interface: Application Software Included, Computer Interface, Other, Serial Interface
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online syngas analyzer Gasboard-3100 is a stationary analyzer with standard 19'' 3U rack enclosure, easy to be integrated inside industrial system. It is able to online continuously measure volume concentration of CO, CO2, CH4, H2 , O2 , CnHm, C2H2 , C2H4 simultaneously, and calculate
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Panametrics
Description: The new XMTCpro is a compact, rugged, online thermal conductivity transmitter that measures the concentration of binary gas mixtures including hydrogen, carbon dioxide, methane, helium and many others. Featuring real-time error detection and enhanced signal measurement for fastest
- Response Time: 20 seconds
- Operating Temperature: -4 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 470 Series CH4 analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CH4. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws
- Response Time: 15 seconds
- Operating Temperature: 40 to 122 F
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Current
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O by
- Response Time: 15 seconds
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This hybrid system is the most cost effective solution to meet the measurement needs in marine applications. Key Features/Benefits: Measure up to 10 gases simultaneously Ambient environments of up to 70°C (158°F) and gas temperatures of 190°C (374°F) Single and dual path options give ppb to %
- Operating Temperature: -4 to 158 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Fuji Electric Corp. of America
Description: Multigas analyser compact and light high performance multigas analyser. The ZSVS up to 4 gas components concentration measurement. Suited for gas monitoring in heat treatment furnaces, plant cultivation, and research-purpose chemical analysis. CO2 – CO – CH4 – O2
- Response Time: 50 seconds
- Operating Temperature: 32 to 104 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Derived from the X-STREAM process gas analyzer, the X-STREAM Enhanced analyzer leads the industry in analytical capabilities and takes process gas analysis to the next level. Offering enhanced performance, extended communication capabilities, and maximum ease of use, the
- Number of Channels: 5
- Response Time: 30 seconds
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The X-STREAM process gas analyzer delivers the analytical tools necessary for precise, accurate gas analysis in a wide variety of applications and environments. Its comprehensive package sets X-STREAM apart from other analyzers by offering multi-component analysis using
- Number of Channels: 4
- Response Time: 30 seconds
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Quantachrome Instruments
Description: High pressure gas sorption measurements are important in the fields of carbon dioxide and methane sequestration, hydrogen storage, and gas separation. The iSorb-HP instruments (volumetric sorption apparatus) generate automatic measurements of full adsorption and desorption
- Measurement Type: %Volume
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Methane (CH4) / Natural Gas
- Mounting Type: Fixed
-
Supplier: COSA Xentaur Corporation
Description: The ZSS is a Highly Efficient Ammonia (NH3), Hydrochloric Acid (HCl), Moisture, Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) and Methane (CH4) Optical Gas Analyzer For Stack Gas Applications. COSA ZSS The ZSS uses a non-dispersive infrared absorbance system
- Response Time: 1.999999999999998 seconds
- Operating Temperature: -4 to 131 F
- Operating Humidity: 0 to 90 %
- Gas Types: Ammonia (NH3), Hydrogen Chloride (HCl)
-
Supplier: Process Sensing Technologies USA
Description: performance analyzer, designed specifically for the measurement of moisture in natural gas. This non-contact technology requires minimal maintenance, even in demanding applications such as changing methane concentrations or sour gas. The analyzer is fully hazardous
- Instrument Type: Analyzer
- Features: Self Calibration
- Measurement Type: Trace
-
Supplier: SAE International
Description: provide proof of performance. The document provides the user a guideline for the FTIR gas analyzer as applied to engine or vehicle emissions testing. This document is applicable to a wide range of fuels including, but not limited to, diesel, gasoline, natural gas, liquid
-
Supplier: SAE International
Description: may not always be the case. The temperature specification applies specifically to the raw gaseous emissions that have not been diluted. If the analysis is to be performed upon a diluted gas stream where the emission gas is at a lower temperature then the analyzer can also be run
-
Supplier: CIQTEK Co., Ltd
Description: shale gas, and coalbed methane adsorption research, petroleum exploration and gas separation and other fields; it is also important for understanding the adsorption performance of some adsorption materials such as catalysts, molecular sieves, and activated carbon, the research
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption)
-
Supplier: BlueSens Gas Sensor GmbH
Description: methane sensors directly in the fermentation container means, none of the measurement data is lost and errors caused by gas leakage or other malfunctions are minimized. The combination of the methane sensors and the precision volumenometers results in a parallel gas
- Gas Types: Methane (CH4) / Natural Gas
-
Supplier: Control Instruments Corp.
Description: For flammable gas monitoring in relatively clean, low temperature, low concentration applications. It’s suitable for single or select solvent ranges and can also be used for mixtures of solvents in processes where normal solvent concentrations are below 25% LFL. Built on proven industrial
- Number of Channels: 1
- Response Time: 4 seconds
- Operating Temperature: -4 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Process Sensing Technologies USA
Description: The XTP601 Oxygen Analyzer for safe or hazardous areas is a robust, linear and stable device that is used for measurements in gases such as biogas, methane, hydrogen, nitrogen or carbon dioxide. The analyzer meets the requirements of IEC61508 SIL2. A robust, linear and stable
- Operating Temperature: 41 to 131 F
- Measurement Type: %Volume
- Instrument Type: Analyzer
- Features: Self Calibration
-
Supplier: Linseis Inc.
Description: Optionally a gas control box and a vacuum pump can be connected. The evolving gases can be analyzed with our integrated QMS, FTIR or In-Situ EGA coupling options. The STA PT1600 HP offers a high pressure ability (up to 5 bar) and many other optional accessories such as Water Vapor generators,
- Temperature Range: -150 to 1,600 C
- Output Options: Analog Voltage
- Remote Interface: Application Software Included, Computer Interface, Other Computer Interface
- Features: Cooling Available, Programmable Heating Rate, Temperature Control
-
Supplier: Control Instruments Corp.
Description: The Model SNR702 is an industrial strength assembly consisting of a heated flame cell and an integrated controller that continuously measures total flammable vapor concentrations from 0 to 100% of the Lower Flammable Limit (LFL) range. Optional modifications allow the SNR702 to sample low oxygen
- Response Time: 1 seconds
- Operating Humidity: 0 to 100 %
- Measurement Type: %LEL
- Application: Ambient Air Monitoring, Process Gas
Find Suppliers by Category Top
Featured Products Top
-
If you’re not monitoring landfill gasses, you’re doing more than risking environmental damage – you’re exposing operations to EPA fines exceeding $50,000 per day. Methane, VOCs, and other hazardous gases don’t just disappear – they (read more)
Browse Gas Sensors Datasheets for Safeguard Analytics -
This TDLAS methane (CH4) module incorporates a laser, photodetector (PD), and gas cell in a miniaturized integrated package, giving you high precision, stability, and reliability (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
These wells are a source of methane gas leakages. Reducing methane emissions is a challenge for the oil & gas industry, as is compliance with emerging regulation. Moreover, increasing gas monitoring density in brownfield sites can be very costly due to signal and power conduit wire (read more)
Browse Gas Instruments Datasheets for United Electric Controls Company -
With a total value of $1 million, the project will enable continuous methane emissions monitoring, mapping, localization and quantification across the entire natural gas supply chain and infrastructure in the country The (read more)
Browse Gas Instruments Datasheets for ABB Measurement & Analytics -
Dynament’s advanced dual-gas infrared sensors are engineered to measure methane (CH?) and carbon dioxide (CO?) simultaneously within a single compact sensor unit—while consuming the power of just one standard infrared sensor. This efficient design helps extend battery life (read more)
Browse Gas Sensors Datasheets for Dynament -
Combining methane, carbon dioxide, and propane measurements within a single compact package, this low-power dual-gas sensor provides an efficient solution for portable gas detection, biogas analysis, and industrial monitoring applications. By integrating multiple sensing channels into one device (read more)
Browse Gas Sensors Datasheets for Dynament -
ABB technology to help tackle methane leakages from orphan oil and gas wells • ABB’s proven emissions monitoring technology now extends to tackling the massive environmental problem of millions of (read more)
Browse Gas Sensors Datasheets for ABB Measurement & Analytics -
The CalorVal BTU Analyzer continuously measures the heating value (Calorific Value) of gaseous streams of industrial processes. Real time: Direct measure of calorific value Fast: Less than 3.5 seconds cell response time Universal: Highly uniform response to a (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp. -
Aii’s portable diving mix analyzers are designed to measure oxygen concentration in diving gas mixtures, supporting safe dive planning and gas verification. Compact and easy to use, they allow divers to confirm oxygen levels before use (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
Flammability Analyzers Versus Flame Ionization Detectors for Process Applications Why have so many fires and explosions occurred in industrial processes that were believed to have adequate protection against such hazards? In many cases, the wrong analyzer was used (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp.
Conduct Research Top
-
Process Gas Monitoring in Petroleum Refineries
Emerson provides Rosemount Analytical gas analyzer technology for on-line analysis of ammonia plant streams. Strategically placed gas analyzers improve the process efficiency and the purity of the end product. Ammonia is used in the production of a variety of products including fertilizer, nitric
-
Super-ambient Pressure Gas Separation Studies Using Breakthrough System Coupled With Mass Spectrometer
The investigation of separation performance of porous materials is very important for evaluation of such materials for separation processes. The separation of methane and carbon dioxide was studied on activated carbon as it appears in many applications such as biogas upgrading or natural gas
-
El Paso Stripper/Cooling Tower HRVOC Analysis (.pdf)
1. Continuously monitor Total HRVOCs, at least every 15 minutes (cooling towers and flares). 2. If use a Total HRVOC Analyzer: * No on-line speciation is required * Total HRVOC reporting satisfies rules * Speciation module available (if required monthly) 3. If use a GC Analyzer: * Report total
-
HRVOC Analysis (.pdf)
, oxygen, nitrogen, carbon dioxide, methane, and ethane). b. If performed by calorimeter: * BTU/SCF Monitored (Temporary Flares) * Method 301 to be performed for stationary flares 5. Record analyzer "up-time": *If a malfunction exceeds 8 consecutive hours, must sample & lab speciate within 24 hours
-
Detection of Volatile Organic Compounds (VOC's) with a Spectrally Filtered Cooled Mid-Wave Infrared Camera
The world's petrochemical industry is constantly seeking methods for the detection of Volatile Organic Compounds (VOC's) such as benzene, propane and methane. Leaks of such materials all too often lead to catastrophic equipment damage and loss of life. EPA regulations require reduction
More Information Top
-
Olli Peltola
F IELD INTERCOMPARISON OF FOUR METHANE GAS ANALYSERS SUITABLE FOR EDDY COVARIANCE FLUX MEASUREMENTS .
-
A Remote Optical Active Gas Analyzer Combined with a Rangefinder
The results of the research and development of an active remote methane gas analyzer combined with a rangefinder (to a reflector) are presented.
-
Methane emission from Siberian arctic polygonal tundra: eddy covariance measurements and modeling
…a rate of 20 L minÀ1 through a CO2/H2O gas analyzer (LI-7000, LI-COR Inc., Lincoln, NE, USA), a membrane gas dryer (PD-200T-48SS, Perma Pure Inc., Toms River, NJ, USA), and the methane gas analyzer , all of which were…
-
Eddy covariance based methane flux in Sundarbans mangroves, India
Peltola O, Mammarella I, Haapanala S, Burba G and Vesala T 2012 Field intercomparison of four methane gas ana- lyzers suitable for eddy covariance flux measurements; Biogeosci.
-
Cross-Validation of Open-Path and Closed-Path Eddy-Covariance Techniques for Observing Methane Fluxes
(2013) Field intercomparison of four methane gas analyzers suitable for eddy covariance flux measurements.
-
Diurnal cycle of lake methane flux
Peltola, O., I. Mammarella, S. Haapanala, G. Burba, and T. Vesala (2013), Field intercomparison of four methane gas analysers suitable for eddy covariance flux measurments, Biogeosci.
-
On‐line estimation of dissolved methane concentration during methanotrophic fermentations
In the present study, we have evaluated the possibility of continuous on-line dissolved methane analysis using a standard infrared methane gas analyzer and a dissolved oxygen (DO) probe.
-
The design and management of system components for in situ methanotrophic bioremediation of chlorinated hydrocarbons
Methane Gas Analyzer .
-
Forest ecosystem changes from annual methane source to sink depending on late summer water balance
Peltola, O., I. Mammarella, S. Haapanala, G. Burba, and T. Vesala (2013), Field intercomparison of four methane gas analyzers suitable for eddy covariance flux measurements, Biogeosciences, 10(6), 3749–3765.
-
A mobile complex for on-line studying water areas and surface atmosphere
In addition, in situ СО2, О2, and methane gas analyzers and sensors of basic parameters of the carbonate system and water pH are developed.
Indicates content that may require registration and/or purchase.