Supplier: Mad City Labs, Inc.
Description: The MCL-MANNZ is an integrated micro-positioner and piezo nanopositioning system for use with inverted optical microscopes. Easy to operate and affordable, the MCL-MANNZ combines a manual micrometer driven, two axis, linear motion stage with a high resolution, z-axis piezo
- Features: Slide Holder
- Maximum X-Distance: 25 mm
- Maximum Y-Distance: 25 mm
- Minimum Step Size (Resolution): 10 µm
-
Supplier: Titan Tool Supply, Inc.
Description: or a Calibrated Reticle for its measuring capacity. The measuring is accomplished by the microscope frame itself moving on a precision dovetail slide. This movement is then read on precision Digital Micrometer reading in .00005" divisions or .001mm. The total measuring capacity
- Application: Measuring / Toolmaker
- Eyepiece Style: Monocular
- Grade: Benchtop
- Total Magnification: 40 X
-
Supplier: Titan Tool Supply, Inc.
Description: Toolmakers Microscope by attaching the unit to the spindle of a vertical milling machine or jig borer and using the travel of the table for measuring the object or construct a set of cross-slides with micrometer movement for positioning a work piece. Grinding: For checking the
- Application: Measuring / Toolmaker, Metallurgical
- Eyepiece Style: Monocular
- Grade: Benchtop
- Total Magnification: 20 to 100 X
-
-
Supplier: Mad City Labs, Inc.
Description: The Nano-View®/M is a fully integrated positioning system for use with inverted optical microscopes. Easy to operate and affordable, the Nano-View/M® combines a manual micrometer driven, two axis, linear motion stage with a high resolution, long range piezo
- Features: Programmable, Slide Holder
- Maximum X-Distance: 0.1000 to 0.3000 mm
- Maximum Y-Distance: 0.1000 to 0.3000 mm
- Minimum Step Size (Resolution): 2.00E-4 µm
-
Supplier: PI (Physik Instrumente) L.P.
Description: Stable platform for P-545 PInano® piezo Nano positioning systems Low profile for easy integration: 30 mm Travel range 25 mm × 25 mm Micrometer screws, motor upgrade available For inverted microscopes made by Nikon, Zeiss, Leica, and Olympus
- Actuation Type: Electrical
- Axis Configuration: X-Y Open Frame
- Carriage Load: 11.24 lbs
- Drive Specifications: Micrometer
-
Supplier: Suzhou Jiujon Optics Co., Ltd
Description: and optical properties of the system. A stage micrometer is a small glass slide containing a grid of precisely scribed lines at known spacing. Grids are often used to calibrate the magnification of microscopes to allow precise size and distance measurements of samples.
- Materials: Specialty / Other
- Parallelism or Wedge Angle: 0.0833 arcmin
- Surface Quality: 40-20 Scratch / Dig
- Wedged or Parallel?: Parallel
-
Supplier: Piezosystem Jena, Inc.
Description: vernier micrometers provide 25 mm adjustment with µm precision, and special piezo-driven micrometer holders (MICI) provide up to 250 µm of nm precise automated motion. Inserts for various sample holders, such as slides, dishes, and SBS, are available.
- Features: Graduated / Measuring
- Maximum X-Distance: 25 mm
- Maximum Y-Distance: 25 mm
- Minimum Step Size (Resolution): 0.1000 µm
-
Supplier: ASTM International
Description: , suitable media, and microscope slides. For specimen examination, the equipments needed are stereomicroscope, dollies, petrographic or polarizing microscope, metallographic microscope, eyepiece micrometer, stage micrometer, microscope lamps,
-
Supplier: ASTM International
Description: useful in showing correlations with many performance properties. The apparatus is comprised of double beam or Fourier transform infrared spectrophotometer, hot plate, microscope slides, compression molding press, metal plates, brass shims, micrometer, and film mounts. Materials
-
Supplier: Titan Tool Supply, Inc.
Description: Toolmakers Microscope by attaching the unit to the spindle of a vertical milling machine or jig borer and using the travel of the table for measuring the object or construct a set of cross-slides with micrometer movement for positioning a work piece. Grinding: For checking the
- Applications: Assembly, Electronics Manufacturing, Industrial Inspection
- Illuminated: Yes
- Magnification: 10 to 20 X
- Type / Mounting: Arm / Boom / Clamp
Find Suppliers by Category Top
Featured Products Top
-
can occur with electromagnetic linear direct drive motors due to insufficient damping or amplifier noise. Accessories A large aperture and many adapter plates allow for the use of microscope slides, well plates and petri dishes. An optional P-736 PInano Z stage or P-545 (read more)
Browse Linear Slides and Linear Stages Datasheets for PI (Physik Instrumente) L.P.
More Information Top
-
The effect of dosage on the efficiency of LLLT in new bone formation at the expanded suture in rats
The photograph of Nikon micrometer microscope slide (MBM11100 Stage Micrometer Type A, Nikon Corporation, Tokyo, Japan) was also taken during the procedure.
-
Haemostatic role and histopathological effects of a new haemostatic agent in a rat bladder haemorrhage model: an experimental trial
A photograph of the Nikon micrometer microscope slide was also taken during the procedure.
-
The effects of chronic administration of sumatriptan and dipyrone on serotonergic system in the rat brain: an immunohistochemical study
The photo- graph of Nikon micrometer microscope slide was also taken during the procedure.
-
The Evaluation of Protective Effects of FK-506 on Neural Ischemic-Reperfusion Injury: an Experimental Study
The pho- tograph of a Nikon micrometer microscope slide was also taken during the procedure.
-
Combination antioxidant effect of α-tocoferol and erdosteine in ischemia–reperfusion injury in rat model
The photograph of Nikon micrometer microscope slide was also taken during the procedure.
-
An early diagnostic tool for diabetic neuropathy: Conduction velocity distribution
The length was cali- brated by comparing the photograph of the speci- men with the photograph of the Nikon microme- ter microscope slide , which was taken under the same magnification.
-
Bigger is better: implications of body size for flight ability under different light conditions and the evolution of alloethism in bumblebees
We measured eye length, eye width, median ocellar diameter (in the horizontal plane) and thorax width (inter-tegulae span) using a stereo microscope (Nikon SMZ-10, Tokyo, Japan) equipped with a measur- ing grid, calibrated with a Nikon micrometer micro- scope slide .
-
Effect of pH on Garlic Oil Encapsulation by Complex Coacervation | Open Access | OMICS Publishing Group
Coacervates were put on a micrometer microscope slide (100mm) and observed using a binocular light microscope (BA200, MoticTM Group, Hong Kong) under objective magnification of 10×.
-
Microscopic Characterization of Particle Size and Shape: An Inexpensive and Versatile Method
A microscope slide micrometer is placed on the micro- scope stage.
-
Compaction Effects in Glass Fibers
A known tensile load is applied and the change in length during a heating and cooling cycle is measured with a micrometer slide microscope .
Indicates content that may require registration and/or purchase.