Supplier: OMEGA Engineering, Inc.
Description: measure the response of the structure. If a Spectrum analyzer or a computer is used, input/response data can display transfer functions and perform modal analysis. The hammer is acceleration compensated, which means that it responds purely to force and is unaffected by the vibration in
- Hand Operation: Yes
- Maximum Force: 1000 lbs
- Maximum Pulse Duration: 300000 milliseconds
- Minimum Force: 1 lbs
-
Supplier: Prosig USA, Inc.
Description: per second per channel are available in 24-bit precision. The DATS Hammer Impact Software includes software tools to capture hammer impact data using the P8004 system. Identification of modal parameters from FRF’s is provided within the Modal Analysis Software. The
- Monitored Properties: Acceleration / Vibration
-
Supplier: PCB Piezotronics, Inc.
Description: Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N)
- Maximum Force: 5000 lbs
- Minimum Force: 5000 lbs
-
-
Supplier: PCB Piezotronics, Inc.
Description: Platinum Stock Products; Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 500 lbf, 10 mV/lbf (2.2 mV/N)
- Maximum Force: 500 lbs
- Minimum Force: 500 lbs
-
Supplier: PCB Piezotronics, Inc.
Description: Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 1000 lbf, 5 mV/lbf (1.1 mV/N), TEDS 1.0
- Maximum Force: 1000 lbs
- Minimum Force: 1000 lbs
-
Supplier: PCB Piezotronics, Inc.
Description: Modally Tuned® Impulse Hammer w/force sensor and tips, 0 to 100 lbf, 50 mV/lbf (11.2 mV/N)
- Maximum Force: 100 lbs
- Minimum Force: 100 lbs
-
Supplier: ECON Technologies Co.,Ltd
Description: analysis of vibration characteristics, system fault diagnosis and prediction, and optimization of structural dynamic properties. This modal analysis system consists of a Modal Exciter or force hammer, test instruments, acceleration pickup and power amplifier, analysis software,
- Application: Modal Excitation Source, Product Qualification / Testing, Reliability / Durability Testing, R&D / Product Design Verification, Seismic Simulation, Structural Fatigue Testing
- Displacement: 0.0 to 1 inch
- Frequency Range: 2000 to 6500 Hz
- Integral Slip Table / Multi-Axis Capability: Yes
-
Supplier: E-Labs, Inc.
Description: , industrial, andmilitary applications. At E-Labs, Inc. our dynamics testing capabilities includethe following: AccelerationTesting Acoustic Noise Classic ShockTesting CombinedEnvironments Vibration Hammer ShockTesting Shock Testing
- Accelerated (HALT / HASS): Yes
- Capabilities: Testing / Simulation, Component / Product Comparisons, Engineering Verification Testing, In-Process In-Line Testing, Performance Testing, Research and Development, Test Fixtures / Equipment
- Combined Environments / Conditions: Yes
- Dynamics Test Services Offered: Acceleration, Aging / Life Testing (HALT), Crash Safety, Drop / Impact Testing, Shock Testing, Transportation Test, Stress Screening / HASS, Vibration (Random / Sine), Specialty / Other
Find Suppliers by Category Top
Featured Products Top
-
exciter-based and impact hammer modal testing Rich trigger and adjustable window functions improve measurement efficiency and data quality (read more)
Browse Data Acquisition Systems and Instruments Datasheets for ECON Technologies Co.,Ltd -
Fourier Transform (FFT), and modal analysis. We’ll work with you to assess the cause and effect of shock pulses, estimating potential damage based on detailed analytical results. If any tests fall short of your specifications, our team will recommend effective solutions to meet (read more)
Browse Shock and Vibration (Dynamics) Testing Services Datasheets for E-Labs, Inc.
More Information Top
-
Topics in Modal Analysis II, Volume 8
However, if a better representation of these modes were needed, some force impacts could have been made on the fixture with a bigger modal hammer .
-
Topics in Modal Analysis, Volume 7
Modal hammer and base excitation tests were performed .
-
Special Topics in Structural Dynamics, Volume 6
The examples of the input forces and modal hammers used are shown in Fig. 13.29.
-
Field validation of a wireless structural monitoring system on the Alamosa Canyon Bridge
Two methods of bridge excitation are considered in this study: a modal hammer is used to deliver impulsive loads and a truck is driven over the bridge deck.
-
Special Topics in Structural Dynamics, Volume 6
The modal hammer excitation was applied at position (5), while the banded white noise was applied at position (3).
-
Modal Analysis Topics, Volume 3
Modal hammer impact testing is often thought to be limited in its ability to provide accurate results for large, heavily damped structures, such as an H1 military vehicle.
-
Health Monitoring of Structural Materials and Components: Methods with Applications
A medium modal hammer PCB 086C03 (10 mV/lb) was used to apply the impact excitation.
-
Experimental Techniques, Rotating Machinery, and Acoustics, Volume 8
23.4.1 Modal Hammer Test .
-
Advanced Aerospace Applications, Volume 1
The modal tests were conducted by using accelerometers and a modal hammer .
-
Structural Health Monitoring 2008: Proceedings of the Fourth European Conference
• modal hammer of the PCB 086CD20 type, .