Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Kooltronic, Inc.
Description: The Guardian Series all-weather air conditioners are designed specifically for NEMA 4 enclosure applications that require protection from washdown or storm conditions. The Guardian Series AC units range in height from 15 to 60 inches, offering 1,000 to 26,000 BTU/H
- Cooling Capacity: 5,000 BTU/hr
- Voltage: 115 VAC
- Features: Enclosure, Industrial, Other
-
Supplier: Kooltronic, Inc.
Description: The Guardian Series all-weather air conditioners are designed specifically for NEMA 4 enclosure applications that require protection from washdown or storm conditions. The Guardian Series AC units range in height from 15 to 60 inches, offering 1,000 to 26,000 BTU/H
- Cooling Capacity: 9,000 BTU/hr
- Voltage: 115 VAC
- Features: Enclosure, Industrial, Other
-
Supplier: Kooltronic, Inc.
Description: The Guardian Series all-weather air conditioners are designed specifically for NEMA 4 enclosure applications that require protection from washdown or storm conditions. The Guardian Series AC units range in height from 15 to 60 inches, offering 1,000 to 26,000 BTU/H
- Cooling Capacity: 1,160 BTU/hr
- Voltage: 115 VAC
- Features: Enclosure, Industrial, Other
-
-
Supplier: Kooltronic, Inc.
Description: The Guardian Series all-weather air conditioners are designed specifically for NEMA 4 enclosure applications that require protection from washdown or storm conditions. The Guardian Series AC units range in height from 15 to 60 inches, offering 1,000 to 26,000 BTU/H
- Cooling Capacity: 2,999.9999999999995 BTU/hr
- Voltage: 115 VAC
- Features: Enclosure, Industrial, Other
-
Supplier: Automation24, Inc.
Description: Enclosure air conditioner Kooltronic WNA4C1DP15LV from the Guardian series of Wiegmann ensures optimal protection from temperature changes for your enclosure. The WNA4C1DP15LV operated at 1000 BTU/H with an operating voltage of 115 V. The Kooltronic WNA4C1DP15LV also
- Cooling Capacity: 1,000 BTU/hr
- Voltage: 115 VAC
- Features: Enclosure, Industrial
-
Supplier: EIC Solutions, Inc.
Description: package at one low price with no assembly required! Enclosures are available in Gray Powder Coated Steel (NEMA 4/12) or Stainless Steel (NEMA 4X) construction. Note: Drawings available on this page show “right side” air conditioner mounting (default
- Length / Height: 24 inch
- Width/Diameter: 24 inch
- Depth: 6 inch
- Height: 24 inch
-
Supplier: Ralston Metal Products Limited
Description: Closed-Loop air conditioners are specifically designed to mount on enclosures to remove heat without letting outside air into the sealed enclosure. This type of cooling is typically used to cool electronic equipment housed in a Nema rated enclosure
- Cooling Capacity: 1,000 to 20,000 BTU/hr
- Voltage: 230 VAC
- Frequency: 50 Hz, 60 Hz
- Features: Commercial, Data Center Cooling, Enclosure, Industrial, Other
-
Supplier: Ralston Metal Products Limited
Description: Closed-Loop air conditioners are specifically designed to mount on enclosures to remove heat without letting outside air into the sealed enclosure. This type of cooling is typically used to cool electronic equipment housed in a Nema rated enclosure
- Cooling Capacity: 2,999.9999999999995 to 5,999.999999999999 BTU/hr
- Voltage: 230 VAC
- Frequency: 50 Hz, 60 Hz
- Features: Commercial, Data Center Cooling, Enclosure, Industrial, Other
-
Supplier: Ralston Metal Products Limited
Description: Closed-Loop air conditioners are specifically designed to mount on enclosures to remove heat without letting outside air into the sealed enclosure. This type of cooling is typically used to cool electronic equipment housed in a Nema rated enclosure
- Cooling Capacity: 1,199.9999999999998 to 8,000 BTU/hr
- Voltage: 230 VAC
- Frequency: 50 Hz, 60 Hz
- Features: Commercial, Data Center Cooling, Enclosure, Industrial, Other
-
Supplier: Hammond Manufacturing Company Inc.
Description: Description Narrow design for side mounting on any enclosure surface where hot spot or low capacity cooling is required. Closed loop cooling ensures clean enclosure air is recirculated without ever mixing with contaminated ambient air. Standards Maintains NEMA 12
- Features: Enclosure, Industrial
-
Supplier: EIC Solutions, Inc.
Description: ThermoTEC™ 3200 BTU/HR Cooling Supplemental Heating Capability Available NEMA 4X (Indoor/Outdoor) Applications Vertical or Horizontal (Top) Mounting 220 VAC Power 23-1/2" H x 19-1/2" W Mounting Flange Made in USA
- Cooling Capacity: 3,199.9999999999995 BTU/hr
- Features: Enclosure, Industrial
-
Supplier: EXM Manufacturing Ltd.
Description: CLOSED LOOP TYPE 12.27 INCH W X 6.34 INCH D X 30.09 INCH H SIZE 50/60 HZ FREQUENCY RATING ENCLOSURE, SIDE INSTALLATION MILD STEEL ENCLOSURE MATERIAL UL, CUL APPROVAL 220 V AT 50 HZ, 230 V AT 60 HZ VOLTAGE RATING NEMA 4/12, IP54 ENCLOSURE 4.6/4.2
- Cooling Capacity: 3,799.9999999999995 BTU/hr
- Voltage: 230 VAC
- Frequency: 50 Hz, 60 Hz
- Features: Enclosure
-
Description: AHP-1800X, XM Series Mounting Style: Through Mounted Voltages: 120/240 VAC and 24 VDC Environments: NEMA-4X IP 56 (X models) NEMA-4X IP 56 + Shock & Vibration (XM models) UL-1995/CSA 22.2, CE Rating Traditional: 1100 BTU/hr @ 0 °F ΔT 1420 BTU/hr @ +20 °F ΔT Rating DIN 3168: 322 Watts
- Features: Enclosure
-
Description: LHP-300FF Series Mounting Style: Internal Mounted Voltages: 24 VDC Environments: NEMA-12 IP40 * Adaptable to NEMA-4/4X & explosion proof apps. Rating Traditional: 160 BTU/hr @ 0 °F ΔT 200 BTU/hr @ +20 °F ΔT Rating DIN 3168: 48 Watts L35 L35 34 Watts L35 L50
- Features: Enclosure
-
Supplier: Hammond Manufacturing Company Inc.
Description: Description Designed for side mounting on any enclosure surface where high capacity system cooling is required. Closed loop cooling ensures clean enclosure air is recirculated without ever mixing with contaminated ambient air. Optimum air circulation with maximum
- Features: Enclosure, Industrial
-
Supplier: APX Enclosures, Inc.
Description: INDUSTRY STANDARD UL Listed NEMA Certified Type 3R, 4X, Bellcore TA-NWT-000487 STANDARD CONSTRUCTION A. ENCLOSURE 1. The complete enclosure is made from 0.125" thick aluminum alloy type 5052-H32 to provide a strong and rigid construction. 2. Each enclosure is equipped
- NEMA Rating: NEMA / IP Enclosures
-
Supplier: EXAIR
Description: Coolers (dust-tight, oil tight, splash resistant, indoor/outdoor service) incorporate a low pressure relief valve for both the vortex tube and the Cabinet Cooler exhaust. The valve closes and seals when the Cabinet Cooler is not operating to maintain the NEMA 4 integrity of the
- Cooling Capacity: 5,599.999999999999 BTU/hr
- Frequency: 50 Hz, 60 Hz
- Features: Enclosure, Industrial, Other, Telecommunications
-
Supplier: APX Enclosures, Inc.
Description: INDUSTRY STANDARD UL Listed NEMA Certified Type 3R, 4X, Bellcore TA-NWT-000487 STANDARD CONSTRUCTION A. ENCLOSURE 1. The complete enclosure is made from 0.125" thick aluminum alloy type 5052-H32 to provide a strong and rigid construction. 2. Each enclosure is equipped
- Type: Electronic and Instrument Enclosures
- NEMA Rating: NEMA / IP Enclosures
-
Supplier: EXAIR
Description: EXAIR Cabinet Coolers incorporate a vortex tube to produce cold air from compressed air - with no moving parts. EXAIR's NEMA 4X (IP66) Cabinet Cooler ® Systems (dust-tight, oil-tight, splash resistant, corrosion resistant, indoor. outdoor service) incorporate a low pressure
- Cooling Capacity: 2,799.9999999999995 BTU/hr
- Features: Enclosure, Industrial, Telecommunications
-
Supplier: APX Enclosures, Inc.
Description: INDUSTRY STANDARD UL Listed NEMA Certified Type 3R, 4X, Bellcore TA-NWT-000487 STANDARD CONSTRUCTION A. ENCLOSURE 1. The complete enclosure is made from 0.125" thick aluminum alloy type 5052-H32 to provide a strong and rigid construction. 2. Both equipment and battery drawer
- Type: Electronic and Instrument Enclosures
- NEMA Rating: NEMA / IP Enclosures
-
Supplier: nVent Electric
Description: The PROTEK Thermal Package is an excellent, off-the-shelf choice for mounting 19-in. rack network equipment in wet or dirty environments where filtration or air conditioning is required and floor space is at a premium. Complete Fan and Filter and Air Conditioner Packages are
-
Supplier: EXAIR
Description: pressure relief valve, which closes and seals when the cooler is not operating to maintain the integrity of a NEMA 4X enclosure. NEMA 4X (IP66) Cabinet Cooler® Systems are recommended when constant cooling and constant positive purge are desirable. Systems for continuous
- Cooling Capacity: 5,599.999999999999 BTU/hr
- Features: Enclosure, Industrial, Other, Telecommunications
-
Supplier: Nex Flow Air Products Corp.
Description: Cabinet Enclosure Cooler / Cooling - Frigid-X™ series for electronic control panels provide a low cost method of both purging and cooling electrical and electronic control panels by using a stainless steel vortex tube to create cold air from ordinary compressed air. Cabinet
- Cooling Capacity: 290 to 2,900 BTU/hr
- Features: Enclosure, Other, Thermostatic Control
-
Supplier: EXAIR
Description: Thermostat controlled Hazardous Location NEMA 4 (IP66) Cabinet Cooler Systems are engineered and approved for use upon purged electrical enclosures found within classified areas. These HazLoc Cabinet Cooler Systems have been tested by UL and meet the stringent UL requirements
- Cooling Capacity: 5,599.999999999999 BTU/hr
- Features: Enclosure, Industrial, Other, Telecommunications
-
Supplier: Oil-Rite Corp.
Description: has a 1/8” female NPT air inlet; this is the only air connection required to operate the entire lubrication system. The painted steel, hinged-door NEMA 12 enclosure is 8” across, 10 3/4” in height, and 6 1/2” in depth. The depth with the door open is about 16”. For
- Operating Pressure: 40 to 120 psi
- Features: Adjustable Volume
- Media: Oil
- Operation: Pneumatic
-
Supplier: VAST STOCK CO., LIMITED
Description: Electrical Enclosures AIR CONDITIONER 2500 BTU 460V SS
- Length / Height: 11.190557224 inch
- Width/Diameter: 10.274414997 inch
- Height: 11.190557224 inch
- Width or Diameter: 10.274414997 inch
-
Supplier: nVent Electric
Description: or right. The mounted cabinet swings open to provide easy equipment service and installation access. Complete Fan and Filter and Air Conditioner Packages are available to match application requirements.
-
Supplier: Transtector Systems, Inc.
Description: IP54 enclosure panel part number TEP141004-40F is constructed of ABS plastic. Our NEMA 12 rating enclosure cabinet is gray in color. This gray ABS plastic enclosure box is designed to adhere to the national electrical manufacturers association NEMA ratings. Our
- Length / Height: 14.5 inch
- Width/Diameter: 10.8 inch
- Depth: 4.3 inch
- Height: 14.5 inch
-
Supplier: Transtector Systems, Inc.
Description: IP24 enclosure panel part number TEP141004-10FW is constructed of ABS plastic. Our NEMA 3R rating enclosure cabinet is gray in color. This gray ABS plastic enclosure box is designed to adhere to the national electrical manufacturers association NEMA ratings. Our
- Length / Height: 14.5 inch
- Width/Diameter: 10.8 inch
- Depth: 4.3 inch
- Height: 14.5 inch
-
Supplier: Transtector Systems, Inc.
Description: electronic equipment. Our national electrical manufactures association NEMA box has the outer dimensions of 14x10x6. The 14x10x6 NEMA enclosure box inner dimensions are 13.6x9.7x5.4. The Transtector UL NEMA panel enclosure is one of many configurations that
- Length / Height: 14.6 inch
- Width/Diameter: 10.6 inch
- Depth: 6 inch
- Height: 14.6 inch
-
Supplier: Vortec
Description: Standard Vortex Enclosure Coolers are available NEMA 12, NEMA 4 and NEMA 4X versions, and can be purchased with an electric thermostat or without a thermostat (constant run). The electrical enclosure cooling thermostat model maintains tight control on the
- Cooling Capacity: 399.99999999999994 to 5,000 BTU/hr
- Features: Enclosure, Other, Thermostatic Control
-
Supplier: Transtector Systems, Inc.
Description: IP24 enclosure panel part number TEP141004-40FW is constructed of ABS plastic. Our NEMA 3R rating enclosure cabinet is gray in color. This gray ABS plastic enclosure box is designed to adhere to the national electrical manufacturers association NEMA ratings. Our
- Length / Height: 14.5 inch
- Width/Diameter: 10.8 inch
- Depth: 4.3 inch
- Height: 14.5 inch
-
Supplier: Nex Flow Air Products Corp.
Description: from the vortex tube is expelled through the top of the air conditioner. The cold air is directed into the enclosure through the cold air distribution hose. Hot air inside the enclosure rises and exits to atmosphere via the air exhaust at a
-
Supplier: Nex Flow Air Products Corp.
Description: from the vortex tube is expelled through the top of the air conditioner. The cold air is directed into the enclosure through the cold air distribution hose. Hot air inside the enclosure rises and exits to atmosphere via the air exhaust at a
-
Supplier: Oil-Rite Corp.
Description: has a 1/8” female NPT air inlet; this is the only air connection required to operate the entire lubrication system. The painted steel, hinged-door NEMA 12 enclosure is 8” across, 10 3/4” in height, and 6 1/2” in depth. The depth with the door open is about 16”. For
- Operating Pressure: 40 to 120 psi
- Features: Adjustable Volume
- Media: Oil
- Operation: Pneumatic
Find Suppliers by Category Top
Featured Products Top
-
engineered for purged and pressurized systems for Class I Div 1, Groups A, B, C, and D; Class II Div 1 Groups E, F and G; and Class III areas. NEMA 12, 4, and 4X Cabinet Cooler Systems are available with a thermostat control or as a continuous operation system. The wear, corrosion and (read more)
Browse Enclosure Air Conditioners Datasheets for EXAIR -
. EXAIR HazLoc Cabinet Coolers circulate 20°F (-7°C) air inside the enclosure to prevent high temperature faults. They mount in a standard electrical knockout while keeping the NEMA 4 or 4X rating of the enclosure. Cabinet Cooler Systems include an auto drain filter separator to ensure no (read more)
Browse Enclosure Air Conditioners Datasheets for EXAIR -
EXAIR Cabinet Cooler® systems provide a rugged, industrial duty solution for cooling and purging electronic cabinets. They are CE compliant and available with cooling capacities up to 5,600 BTU/Hr. and UL listed NEMA 12, NEMA 4, and NEMA 4X enclosure ratings. There are also UL (read more)
Browse Enclosure Air Conditioners Datasheets for EXAIR -
EXAIR's Small 316 Stainless Steel Cabinet Cooler® Systems with ETC (Electronic Temperature Control) keep electrical enclosures cool with 20°F (-7°C) air while maintaining the NEMA 4X rating of the enclosure and resisting the heat that could adversely affect the internal components (read more)
Browse Enclosure Air Conditioners Datasheets for EXAIR -
1, Div 2). All of Vortec's Enclosure Coolers keep Electrical and Electronic Enclosures cool, clean, and protected and are a low-cost alternative to expensive, high maintenance air conditioners; and avoid contamination with dirty, humid air caused by fans. Today's small, compact (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec -
1, Div 2). All of Vortec's Enclosure Coolers keep Electrical and Electronic Enclosures cool, clean, and protected and are a low-cost alternative to expensive, high maintenance air conditioners; and avoid contamination with dirty, humid air caused by fans. Today's small, compact (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec -
implementation. 4. Compliance and Protection Vortec coolers are UL-listed and rated for NEMA 4, 4X, and 12 enclosures, offering proven protection against ingress of dust, water, and corrosion. Real-World Impact (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec -
avoid unplanned downtime in your manufacturing plant. A common low-cost cooling alternative is to use compressed air with vortex tube coolers to maintain a low internal temperature in enclosures. Vortex tube coolers keep enclosures cool due to the vortex tube phenomenon, learn more about this phenomenon (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec -
1, Div 2). All of Vortec's Enclosure Coolers keep Electrical and Electronic Enclosures cool, clean, and protected and are a low-cost alternative to expensive, high maintenance air conditioners; and avoid contamination with dirty, humid air caused by fans. Today's small, compact (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec -
determined the total heat load in the enclosure based on Jeff's inputs and compressed air conditions. The Vortex A/C 7715 NEMA 4/4X enclosure cooler was the best solution, a model that uses 15 scfm of compressed air to produce 900 btuh of cooling and required no electricity to operate. A built (read more)
Browse Enclosure Air Conditioners Datasheets for Vortec
Conduct Research Top
-
CABINET COOLERS END COSTLY SHUTDOWNS
combined with heat put out by their laser cutting machine took the temperature of the non-air-conditioned shop up over 100°F. Soon, the heat took its toll on the electrical enclosures of the laser cutting machine. The computer produced a lot of error messages and stopped the operation. Lasercraft
More Information Top
-
Selecting ASD systems
This usually requires a NEMA 4 enclosure with an adequately sized air conditioner mounted on the enclosure to maintain the temperaturerisewithin specifications.
-
NOx CONTROL OPTIONS AND INTEGRATION FOR US COAL FIRED BOILERS
The partially prepared sample gas exits the preconditioner module and is directed to a NEMA 4 air conditioned enclosure containing a Horiba Sample Conditioner Model ES-C510, a Horiba Model CLA-510 Chemiluminescent NO-NOx Analyzer and a Horiba Model MPA-510 …
-
Operations and maintenance manual for the light duty utility arm (LDUA) at-tank instrument enclosure (ATIE) (LDUA system 4300)
1.2 EQUIPMENT DESCRIPTION 1.2.1 General Description The design of the ATIE is based on an Electrorack three-bay, NEMA - 4 weathertight instrument enclosure with an external air conditioner .
-
NOx CONTROL OPTIONS AND INTEGRATION FOR US COAL FIRED BOILERS
The partially prepared sample gas exits the preconditioner module and is directed to a NEMA 4 air -conditioned enclosure containing a Horiba Sample Conditioner Model ES-C510, a Horiba Model CLA-510 Chemiluminescent NO-NOx Analyzer and a Horiba Model MPA-510 …
-
NEMA Application Guide for AC adjustable speed drive systems
This usually requires a NEMA 4 enclosurewith an adequately sized air conditioner mounted on the enclosure to maintain the temperature rise within soecifications.
-
CR4 - Thread: NEMA 4 Enclosure With Louvers??
If your equipment needs cooling and it needs to be in a NEMA 4 enclosure , then you have two viable choices: A NEMA 4 rated closed loop air conditioner or a NEMA 4 rated closed loop heat exchanger.
-
Countries > Canada > National > Gazette > 2010 > Part I > [CANADA Gazette Part i, 2010-0612] Part I‚ June 12‚ 2010‚ Vol. 144‚ No. 24
… or eight pole construction; (h) has an IP code from 00 to 66; (i) is of open or enclosed construction; (j) is of … … does not include a NEMA design A or C … … 375 kW; (moteur) “room air - conditioner ” means a single … … mode de réfrigération dans lequel la température moyenne des boissons réfrigérées peut atteindre 4 ,4 °C, (ii …
-
Standard-D hydrogen monitoring system, system design description
The heater is panel mounted inside the enclosure and the air conditioner is mounted on the side of the enclosure . 3.6.2.1 Enclosure The enclosure containing the Standard Hydrogen Monitoring System is a free standing single door NEMA 4 enclosure.
-
HVAC Pump Handbook, Second Edition > Pump Drivers and Variable-Speed Drives
If there is a need for a nonventilated enclosure for use with internal air- conditioners or ducted cooling air , the Nema 12 type is usually the best enclosure (see Fig. 7.16a). 4 .
-
Standard-C hydrogen monitoring system, system design description
The heater is panel mounted inside the enclosure and the air conditioner is mounted on the side of the enclosure . The enclosure containingthe Standard Hydrogen Monitoring System is a free standing single door NEMA 4 enclosure.
Indicates content that may require registration and/or purchase.