Products/Services for North Coast GE Detector
-
Heat Detectors - (104 companies)Heat detectors are fire detection devices that sense heat produced by combustion. Heat detectors can trigger an alarm when they detect rapid temperature rise or reach a preset temperature. Heat detectors are fire detection devices that sense heat...MarketDetector StylePower -
GC Detectors - (38 companies)Gas chromatography detectors (GC detectors) identify solutes as they exit the chromatographic column. A chromatogram is generated plotting the signal versus time. Gas chromatography detectors (GC detectors) identify solutes as they exit... -
Flame Detectors - (182 companies)Flame detectors monitor and analyze incoming radiation at selected wavelengths. Flame detectors use optical sensors working at specific spectral ranges (usually narrowband) to record the incoming radiation at the selected wavelengths. Typically, 30... -
Smoke Detectors - (260 companies)Smoke detectors are designed to sense the products of combustion. Common types include ionization chambers and photoelectric devices. Smoke detectors are designed to sense the products of combustion. They are designed for commercial, industrial... -
HPLC Detectors - (49 companies)High performance liquid chromatograph (HPLC) detectors pass a beam of light through a column effluent as the fluid passes through a low-volume flow cell. Variations in light intensity are recorded and a chromatograph is generated. HPLC detectors use... -
Radiation Detectors - (204 companies)Radiation detectors are used for medical diagnoses, radioactive dating measurements, and measurements of background radiation, activity levels and radiation doses. Radiation detectors are devices used to detect, track, and identify ionized radiation...
-
Liquid Leak Detectors - (257 companies)Liquid leak detectors sense when a liquid is leaking from a pipe, tank, or other receptacle. Liquid leak detectors sense when a liquid is leaking from a pipe, tank, or other receptacle. Leaks are often conceptualized as being small, round defects...
-
RF Phase Detectors and Comparators - (55 companies)RF phase detectors and comparators are circuits or instruments that provide a DC output voltage proportional to the difference in phase between two RF signals. They include local oscillator (LO), radio frequency (RF), and intermediate frequency...
-
Flaw Detectors - (252 companies)Flaw detectors are used to detect or measure defects in raw materials or finished products. This product area includes fault detectors, NDT instruments that are used to find faults in electrical, mechanical, optical, or other systems. Examples...
-
Current Testers and Detectors - (45 companies)Current testers and detectors check for the presence of current flow in electrical circuits. They are also used to locate current in hidden wires and cables. Measurement type and measurement range are important specifications to consider. Types...
Product News
-
Avantier Inc.
Ge MWIR Lenses Within our ready-to-order selection, our MWIR lenses offer focal lengths ranging from 25 to 250, accommodating a field angle spanning 7 to 27.6 degrees. These readily available options feature manual focus mechanisms, with a versatile range of interfaces, including C-mount, M50x1, M60x1/Flangle, M36x1, and M32x1. All our MWIR lenses are impeccably engineered to seamlessly integrate with a 640 x512-15um detector, ensuring optimal performance. Should our offerings not precisely match your... (read more) -
Avantier Inc.
Ge LWIR Lenses LWIR cameras, powered by our lenses, revolutionize diverse fields. They enhance factory quality control, facilitate predictive maintenance in industries, and enable unhindered surveillance through smoke and fog. Our lenses excel in gas leak detection, preempting hazards. In medical arenas, LWIR thermal imaging detects cellular-level temperature changes, aiding detection of conditions like cancer, tumors, diabetes, and trauma. With a commitment to excellence, Avantier ensures LWIR performance. (read more) -
Dexter Research Center, Inc.
High Temperature Infrared Detector Dexter Research Center announces the availability of its new ST60 High Temperature Detectors. The specially constructed MEMS based thermopiles can withstand operating temperatures of 300 C with silicon windows and 225 with coated windows. The silicon-based detectors are available in TO-5 packages with an active are of 0.61mm x 0.61mm. The new High Temperature detector offers exciting performance opportunities in non-contact temperature measurement applications such as work piece monitoring... (read more)Browse Noncontact Infrared Temperature Sensors Datasheets for Dexter Research Center, Inc. -
InfraTec GmbH
PYRONEER Detectors with Lithium Tantalate The Rugged Ones - PYRONEER Detectors with Lithium Tantalate. LSV-Detectors combine reliability and long-term stability. Detectors for use in analytical devices and in spectroscopy have been part of InfraTec's portfolio for over 20 years. From the very beginning, these are based on high-quality, single-crystal lithium tantalate (LiTaO3). Introducing DLaTGS as a pyroelectric material last year, InfraTec developed the new PYRONEER series, which also includes spectrometer detectors based on LiTaO3... (read more)Browse Gas Sensors Datasheets for InfraTec GmbH -
Dexter Research Center, Inc.
Thermopile Detector for Gas Analysis Dexter Research - Gas Analysis Thermopile Detector. Applications: Excellent for gas analysis, position sensor, and horizon sensor. A four-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ C. This detector has a very short thermal shock response to ambient temperature change. View additional information... Leader in Infrared... (read more) -
InfraTec GmbH
What are the advantages of a Pyroelectric Detector What is the advantage of a Pyroelectric Detector with an Integrated Beam Splitter?. Beam splitter detectors are multi-channel detectors with only a single aperture. The incoming radiation is divided into two or four spectral channels by micro mirrors inside the detector. The 2.5 mm diameter aperture allows the use of very small cuvettes for NDIR gas analysis. This results in a very low dead volume for the measurement system. In addition, many effects negatively influencing the measurement act... (read more)Browse Gas Sensors Datasheets for InfraTec GmbH -
Finder S.p.A. con unico socio
Small size movement detectors Function and features. Type 18.01 PIR movement detectors for indoor installation - wall mount. 1 NO 10 A. Output is electrically common to the supply voltage. Small size. Equipped with Light Dependent sensor and delay time. Switch off delay adjustment. Can be used in any position for movement detection. Wide detection angle (read more)Browse Motion and Occupancy Detectors Datasheets for Finder S.p.A. con unico socio -
Dexter Research Center, Inc.
Gas Analysis...Thermopile Detector Dexter Research Center, Inc. A four-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ C. This detector has a very short thermal shock response to ambient temperature change. Features: A four-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen... (read more) -
MSA Safety
See Flame Detectors in Action Explore MSA's flame detection capabilities with their on-demand demo at their state-of-the-art Detection Experience Center. Observe how MSA's flame detectors are designed to respond to the presence of flame, demonstrating their intended functionality under controlled conditions. Topics Covered Include: Review of facility, equipment, and test plan. Standard Fuel Type Selection. Test Lamp Response Test. Baseline Detection Test. Nuisance Alarm Rejection Tests. Field of View Detection Response... (read more)Browse Flame Detectors Datasheets for MSA Safety -
MSA Safety
Gas Detector with Exceptional Durability with legacy General Monitors detectors. Learn More. Request Info... (read more)Browse Gas Instruments Datasheets for MSA Safety
-
Use of Q‐switched lasers in near‐infrared fourier transform Raman spectroscopy. I
Oscilloscope traces showing the response of (A) the North Coast Ge detector system (1 )rs per division) and ( 6 ) the Epitaxx InGaAs detector system (5 ps per division) to laser pulses delivered at 3kHz.
-
InGaAsN: A Novel Material for High-Efficiency Solar Cells and Advanced Photonic Devices
was measured with a Fourier transform spectrometer equipped with a cooled, North Coast Ge detector .
-
Effect of inter-layer strain interaction on the optical properties of Ge/Si(001) island multi-layers
… cap/spacer coverage on the optical emissions was studied by CL spectroscopy carried out as a function of tem- perature and injection power conditions by a commercial Gatan Mono CL2 system using a LN cooled North Coast Ge detector attached to a Cambridge …
-
The growth of infrared antimonide-based semiconductor lasers by metal-organic chemical vapor deposition
Photoluminescence of the N- containing materials was also measured with a Fourier transform spectrometer equipped with a cooled, North Coast Ge detector .
-
Low energy electron excited nanoscale luminescence spectroscopy of erbium doped AIN
A LN2 cooled North Coast Ge detector was used for spec- tral measurements between 0.75 eV and 1.75 eV (1652 nm < λ < 708 nm), while a Peltier-cooled S-20 photomultiplier was used to cover the range from 1.40 …
-
Excitation of Intra-4f Shell Luminescence of Rare Earth Ions (Er3+ and Yb3+) by the Energy Transfer from Si Nanocrystals
Photoluminescence spectra were measured using a HR-320 (Jobin Yvon) monochromator and an EO- 817L ( North Coast ) Ge detector .
-
Low-temperature photoluminescence in SiGe single quantum wells
The samples are cooled in a liquid-He cryostat down to 2 K. PL is then analysed by a monochro- mator of 1-m focal length and detected by a liquid-nitrogen cooled North Coast Ge detector .
-
Photoluminescence studies of carbon- and oxygen-related radiation damage point defects in crystalline silicon
A Nicolet Fourier transform spectrometer was used to analyse the luminescence and the detector was a North Coast Ge detector .
-
New glasses in the system InF3-BaF2-ErPO4
Room temperature emission and excitation spectra were obtained with a Spex Fluorolog F121 spectrofluonmeter equipped with a 450 W Xe lamp as excitation source and a Hamamatsu 950 photomultiplier and a North Coast Ge detector for detection within the visible and JR …
-
InGaAsN Solar Cells with 1.0eV Bandgap, Lattice Matched to GaAs
Photoluminescencewas measured with a Fourier transform spectrometer equipped with a cooled, North Coast Ge detector .
Indicates content that may require registration and/or purchase.