Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ABB Measurement & Analytics
Description: CL3020 is so compact that two NOx cells may be mounted inside a single housing allowing continuous NOx speciation or NH3 measurement. The simplicity of the design also leads to much greater reliability. No more high voltage power supplies, exposed thermo-electric cooling or fragile
- Operating Temperature: 40 to 100 F
- Gas Types: Ammonia (NH3), Nitric Oxide (NO), Oxygen (O2)
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Simplified operation and ease of maintenance are the key design features of Emerson's Rosemount Analytical 951C NOx Analyzer. Designed for source emissions analysis in Continuous Emission Monitoring Systems (CEMS), the 951C delivers top performance and reliability. With the
- Operating Temperature: 40 to 104 F
- Instrument Type: Analyzer
- Display: Digital
- Mounting Type: Fixed
-
Supplier: HORIBA Instruments, Inc.
Description: into a compact body for real-time measurement of NO and NOx emitted from gasoline, diesel, and LPG engines--allowing you to measure NOx in a variety of locations. Use it as a single component analyzer or as a MEXA-7000 add-on. This compact and robust design has been engineered
- Operating Temperature: 41 to 104 F
- Electrical Output: Analog Voltage Output
- Display Type: Digital Display
- User Controls: Digital Front Panel
-
-
Supplier: Teledyne Monitor Labs, Inc.
Description: The sensor-e® NOx uses the proven chemiluminescence detection principle, coupled with state-of-the-art microprocessor technology to provide the sensitivity, stability and ease of use needed for ambient or CEM monitoring requirements. The analyzer uses multi-tasking software which
- Number of Channels: 1
- Response Time: 19.99999999999998 seconds
- Operating Temperature: 41 to 104 F
- Application: Ambient Air Monitoring
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Input/Output (I/O) Module and Platform or it can be integrated into a sophisticated multicomponent analysis network. The WCLD analyzer module is designed to meet stringent U.S. Environmental Protection Agency requirements for NOx monitoring. Features Heated sample handling module for
- Response Time: 1.000000000000002 seconds
- Operating Temperature: 50 to 104 F
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Emerson’s Rosemount Analytical NGA 2000 CLD NO/NOx analyzer module was the industry’s first modular chemiluminescence analyzer. It is a self-contained unit complete with detector and electronics. The modular design allows for easy system integration. The CLD analyzer
- Response Time: 1.000000000000002 seconds
- Operating Temperature: 41 to 104 F
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 313 Series Portable Flue Gas Analyzer for NO, NO2, or NOx utilizes reliable, stable NO and/or NO2 sensors which respond quickly to the NO or NO2 present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 312 Series Portable Flue Gas Analyzer for NOX utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOX found in flue gases or engine exhaust (except
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: WohlerUSA, Inc.
Description: Wohler A 400 Combustion Analyzer with NOx Measuring CapabilitySimply genius - the Wohler A 400 Flue Gas Analyzer is the multifunctional instrument for residential and light commercial applications. The A 400 NOx offers a Nitric Oxide sensor and through the integrated
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 362 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. Model 362 has customer-replaceable sensors, which respond quickly to the O2, CO, and NOx present in
- Response Time: 20 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
-
Supplier: Nova Analytical Systems Inc.
Description: sensor life expectancy is between 3 and 4 years. The CO and NOx sensor life is 2-3 years. The O2, CO, and NOx sensors are customer-replaceable. The CO2 sensor should not need to be replaced.In operation, a built in sample pump draws in the flue gas sample through the S.S. probe, 12 ft.
- Response Time: 20 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
-
Supplier: SAE International
Description: A study has been conducted to measure the transient HC, NOx, CO, CO 2 and particulate emissions from a modern 1.6-liter, Euro IV-stage turbocharged Gasoline Direct Injection (GDI) passenger car engine. The tests were conducted using ultra-fast-response analyzers with millisecond
-
Supplier: InspectorTools
Description: analyzer on the market today, the new ECA 450 from Bacharach conducts accurate combustion and emissions tests that will help you meet environmental regulations and ensure your equipment is burning efficiently. The ECA 450 measures Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide and
-
Supplier: Fuji Electric Corp. of America
Description: NO2 to NO converter for NOx measurements. NOx Converters are utilized in combustion plants, incineration, steel plants, furnace control, CEMS, research labs, and more.
- Application: Confined Space Monitoring
- Mounting Type: Fixed
- Gas Types: Nitric Oxide (NO), Nitrogen Dioxide (NO2)
-
Supplier: C.I. Analytics, Inc.
Description: Process Analyzer If you require a dependable process analyzer for Total Nitrogen OR NOx the 9740, equipped with a chemiluminesence detector meets your needs. The 9740 has most of the standard features listed for 9700 series, but replaces the technology used for analysis. The
-
Supplier: Bacharach, Inc.
Description: testing, NOx filtering, etc. The Monoxor® Plus is the perfect tool for home/safety inspectors, maintenance personnel and HVAC contractors who need to monitor CO in ambient air or stack gases. It has many advanced features, including a trending graph with real-time value displayed, minimum and
- Operating Temperature: 23 to 113 F
- Operating Humidity: 15 to 90 %
- Instrument Type: Analyzer
- Gas Types: Carbon Monoxide (CO), Combustible Gas
-
Supplier: Bacharach, Inc.
Description: sensors for O2 and CO, with an option for an external NOx filter. The CO sensor can be replaced in the field without down time using B-Smart® pre-calibrated sensors. The InTech® calculates values like efficiency, CO2 and CO air-free to help monitor combustion processes effectively and
- Operating Temperature: 23 to 113 F
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Gas Types: Carbon Monoxide (CO), Combustible Gas, Oxygen (O2)
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Rosemount Analytical is the leader in oxygen flue gas analyzer technology. The 6888 continues the tradition of integrating an oxygen probe and field electronics into a single, compact package. The probe inserts directly into a flue gas duct to measure oxygen in combustion processes. No
- Operating Temperature: -40 to 158 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
- Features: Combustible Gas, Other
-
Supplier: Siemens Process Instrumentation
Description: The in-situ gas analyzer LDS 6 is characterized by a high availability and unique analytical selectivity and is optimally suitable for numerous applications. One or two signals from up to three measuring points are processed simultaneously by the central analyzer unit. The sensors are
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Oxygen (O2), Toxic Gas, Water Vapor
- Instrument Type: Analyzer
- Display: Digital
- Number of Gases Monitored: Multi Gas
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O by
- Response Time: 15 seconds
- Operating Temperature: 32 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Fuji Electric Corp. of America
Description: Optimization of combustion efficiency and compliance with environmental standards. Ideal for combustion control in boilers, incinerators, and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy. This oxygen analyzer is used to continuously measure oxygen concentration in
- Response Time: 10 seconds
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Fuji Electric Corp. of America
Description: Optimization of combustion efficiency and compliance with environmental standards. Ideal for combustion control in boilers, incinerators, and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy. This oxygen analyzer is used to continuously measure oxygen concentration in
- Response Time: 20 seconds
- Operating Temperature: 32 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: InspectorTools
Description: analyzer on the market today, the new ECA 450 from Bacharach conducts accurate combustion and emissions tests that will help you meet environmental regulations and ensure your equipment is burning efficiently. The ECA 450 measures Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide and
-
Supplier: Bacharach, Inc.
Description: Measures up to 7 gases simultaneously (minimum O2 and CO), including NOx, SOx and combustibles Sensors are easily replaced or upgraded in the field Rugged suitcase design with large, easy-to-read display Built-in printer for instant traceability and record-keeping The ECA 450 is an industrial
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NxOx), Sulfur Dioxide (SO2)
- Display: Digital
-
Supplier: Siemens Analytical Products
Description: The basic design of the diode laser gas analyzer LDS 6 enables further opportunities in process gas analytics and continuous emission monitoring. The major part of the benefits the in-situ approach is introducing belongs to the simple fact that the measurement is performed non-intrusively and
-
Supplier: Bacharach, Inc.
Description: Measures up to 4 gases simultaneously (minimum O2 and CO), including NOx using NO only or NO + NO2 Exclusive B-Smart® pre-calibrated sensors for easy field replacement or upgrades 3.5 inch color LCD with customizable layout and zoom for viewing the readings you want to see Ten standard fuels
- Operating Temperature: 32 to 212 F
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NxOx), Sulfur Dioxide (SO2)
- Display: Digital
-
Supplier: COSA Xentaur Corporation
Description: sized boilers, as combustion controllers, achieving a significant energy-saving effect. The oxygen concentration control ensures complete combustion, thus reducing CO2, SOX, and NOX emissions and helping prevent global warming and air pollution. Zircomat Stack Oxygen Analyzer The
- Operating Temperature: -4 to 140 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Siemens Analytical Products
Description: The basic design of the diode laser gas analyzer LDS 6 enables further opportunities in process gas analytics and continuous emission monitoring. The major part of the benefits the in-situ approach is introducing belongs to the simple fact that the measurement is performed non-intrusively and
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Oxygen (O2), Toxic Gas
- Electrical Outputs: Analog Current
-
Supplier: HORIBA Instruments, Inc.
Description: system research and development to evaluate sulfur poisoning in de-NOx system, such as LNT (Lean NOx Trap) and Four Way Catalyst (NOx and PM reduction system simultaneously). Total sulfur measurement: "Lubricant Oil Consumption" using the sulfur trace method *1: Total reduced
- Display Type: Digital Display
- User Controls: Digital Front Panel
- Form Factor: In-Situ / Field
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
-
Supplier: SAE International
Description: measured exhaust NO concentrations. In this study the effects of pressure fluctuations on the NOx-specific fuel consumption (SFC) tradeoff are determined. The investigation is performed on a single-cylinder heavy-duty diesel engine, and focuses on the variation of injection parameters
-
Supplier: InspectorTools
Description: analyzer on the market today, the new ECA 450 from Bacharach conducts accurate combustion and emissions tests that will help you meet environmental regulations and ensure your equipment is burning efficiently. The ECA 450 measures Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide and
-
Supplier: ABB Measurement & Analytics
Description: The basic version is equipped with ABB’s renowned Uras26 non-dispersive IR gas analyzer and measures simultaneously and continuously SO2, CO2. Two separate gas paths allows continuous CO2/SO2 measurement of separate streams with only one analyzer and up to 4 components per
- Operating Temperature: 32 to 131 F
- Display Type: Digital Display
- Features and Functionality: Filters
- User Controls: Manual Controls
-
Supplier: Siemens Analytical Products
Description: Low NOx Continuous Emissions Monitoring System (CEMS) EPA COMPLIANT The Standard CEMS is a low cost emissions monitoring package designed to operate in a general purpose, environmentally controlled shelter or cabinet. The targeted markets are NOX reduction sites at Refining,
-
Supplier: SAE International
Description: emissions are measured in accordance with SAE Recommended Practices J177, J215, and J244 using nondispersive infrared equipment for CO and CO 2 , a heated flame ionization analyzer for HC, and a high performance NDIR or a chemiluminescence analyzer for NOx. All emissions are
-
Supplier: SAE International
Description: the time, resulting in a CVS bag dilution ratio in the range of 100 to 300. The CVS dilution ratio should be in the range of 5-25 for accurate results. At higher dilution ratios, the gas concentrations of CO, NOx and THC approach the ambient background level in the test cell. At a dilution of
Find Suppliers by Category Top
Featured Products Top
-
, partially burned fuels, varnish, and lacquers. All of these particles contaminate the oil. Sulfur Oxides (Sox) are common gases with sulfurous fuels (diesel, liquid fuel distillates, heavy fuel oil); Nitrous Oxides (NOx) are more pronounced with Natural gas (CNG, LNG, Propane) fueled engines. Hydrocarbon (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
with plant operations. PEMS allows plant owners and operators a better control on costs, neglecting unexpected costs due to unpredicted issues in the conventional hardware analyzers. PEMS can help you in achieving regulatory compliance applied (read more)
Browse Gas Sensors Datasheets for ABB Measurement & Analytics -
trusted. For modern monitoring programs, that trust must be sustained over long timeframes, across changing environmental conditions, and under increasing regulatory scrutiny. Calibration is crucial for maintaining data integrity. Monitoring stations must routinely verify analyzers measuring (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc.
Conduct Research Top
-
Prevent Ammonia Slip and Gas Greater Efficiencies in Your Plant's NOx Reduction System with Quantum Cascade Laser Analyzers
Nitrogen oxides (NOX) result from the combustion process in turbines, crackers, combustion engines, boilers, and other locations within a plant. As a powerful pollutant, it is important to control and contain NOX emissions. Both Selective catalytic/non-catalytic reduction (SCR and SNCR
-
Direct In Situ Zirconia Oxygen Analyzer (.pdf)
The EXAxt Zircon Oxygen Analyzer (Model ZR402G) is used to monitor and control the oxygen concentration in combustion gases, in boilers and industrial furnaces, for wide application in industries which consume considerable energy-such as steel, electric power, oil and petrochemical, ceramics, paper
-
AQ6375 Optical Spectrum Analyzer for Long Wavelength Band
In recent years, global environmental issues have received increasing attention, promoting effective initiatives to reduce greenhouse gases. In addition to CO2, a well known greenhouse gas, there are other gases that can damage the environment, including SO2 (sulfer dioxide) and NOX (nitrogen
-
Insitu Analysis of Ammonia Slip and Water Vapor Using a Tunable Diode Laser for SCR/SNCR Optimization and Boiler Tube Surveillance in Power Plants
Environmental regulations driven by the 1990 Clear Air Act require Power Plants to reduce NOx emissions. SCR's and SNCR's reduce NOx emission by injecting ammonia into the combustion flue gas, which ideally reacts with the NOx to form H2O and N2. The efficiency of the SCR/SNCR is determined
More Information Top
-
Federal Register > Friday, September 10, 2004 > [69 FR 54846] Test Procedures for Testing Highway and Nonroad Engines and Omnibus Technical Amendments
1065.374 ZrO2 NOX analyzer NH3 interference and NO2 response checks.
-
THOR Bench-Scale Steam Reforming Demonstration
NOx Analyzer Performance, Calibrations, and Quality Control ............................................
-
TWR Bench-Scale Steam Reforming Demonstration
NOx Analyzer Performance, Calibrations, and Quality Control ..............................................
-
THOR Bench-Scale Steam Reforming Demonstration
NOx Analyzer Performance, Calibrations, and Quality Control ............................................
-
Investigation into the Performance of an Ultra-fast Response NO Analyser Equipped with a NO2 to NO Converter for Gasoline and Diesel Exhaust NOx Measurements
Figure 1 Schematic of the overall ultra-fast NOx analyser system, consisting of the fNOx400 head with the new converter accessory LABORATORY CONVERTER TESTS Performance criteria were established in bench tests with NO & NO2 span gases as follows: Conversion efficiency, (the …
-
Continuous Emissions Monitoring System Monitoring Plan for the Y-12 Steam Plant
A NOx U.S. Environmental Protection Agency (EPA) Protocol 1 calibration gas will be used to perform the span calibration on the NOx analyzer , while a CO2 EPA Protocol 1 calibration gas will be used to perform the span calibration on the …
-
Phase 2 THOR Steam Reforming Tests for Sodium Bearing Waste Treatment
The two NOx analyzers used in CEMS 1 during this test are based on different measurement techniques.
-
Advanced combustor design concept to control NOx and air toxics
154 A.5.3: Chemiluminescent NOx Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
Chemiluminescence analyzer of NOx as a high-throughput screening tool in selective catalytic reduction of NO
The applicability of the commercial NOx analyzer as a rapid screening tool was evaluated using selective catalytic reduction of NO gas.
Indicates content that may require registration and/or purchase.