Supplier: HORIBA Instruments, Inc.
Description: The HE-960TM offers high precision measurement of the conductivity of TMAH (Tetra Methyl Ammonium Hydroxide) solutions, the main component of the photoresist developer that is used in semiconductor and liquid crystal processes. The HE-960TM is also an environmentally-frie ndly product
- Display Type: Digital Display
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: In-Situ / Field
- Temperature Compensation: Yes
-
Supplier: OMEGA Engineering, Inc.
Description: The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional sensors, and plating bath operations in which high current densities are present. The sensor consists of 2 metallic ribbon
- Conductivity / Dissolved Solids Range: 10000 to 1.00E6 µS/cm
- Control Relays: 2
- Controller Functionality: Yes
- Display Type: Digital Display
-
Supplier: ABB Measurement & Analytics
Description: ACA592 transmitter is compatible with ABB's full range of conductivity sensors. Automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000 and 3K Balco is included as standard. Data Transmitter options for all sensor
- Conductivity / Dissolved Solids Range: 0.0 to 2.00E6 µS/cm
- Conductivity Accuracy: 1.00E-3 to 1 ±% Full Scale
- Electrical Output: Analog Current Output
- Measures Conductivity / Dissolved Solids: Yes
-
-
Supplier: SWAN Analytical USA, INC.
Description: The portable AMI INSPECTOR is a complete on-line monitoring system mounted on a small panel with supporting stand and a rechargeable battery for stand-alone operation, designed as an inspection equipment for quality assurance of online, conductivity process monitors. Features
- Battery Powered: Yes
- Conductivity / Dissolved Solids Range: 0.0550 to 1000 µS/cm
- Conductivity Accuracy: 1 ±% Full Scale
- Control Relays: 2
-
Supplier: OMEGA Engineering, Inc.
Description: forward system calibration. Tough body construction in cast aluminum, finished with electrostatic epoxy paint. The enclosure has an NEMA 7X (IP68) rating and Intrinsically Safe electronics inside. The 4 to 20 mA analog output has galvanic isolation of 2000 Vac (by opto coupler) and line resistance
- Current Output: Yes
- Form Factor: Panel / Chassis Mount, Other
- Isolation: Other
- Operating Temperature: 41 to 104 F
-
Supplier: SWAN Analytical USA, INC.
Description: The portable AMI INSPECTOR is a complete on-line monitoring system mounted on a small panel with supporting stand and a rechargeable battery for stand-alone operation, designed as an inspection equipment for quality assurance of online, conductivity process monitors. Features
- Battery Powered: Yes
- Conductivity / Dissolved Solids Range: 0.0550 to 1000 µS/cm
- Conductivity Accuracy: 1 ±% Full Scale
- Control Relays: 2
-
Supplier: Myron L Company
Description: increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface
- Conductivity / Dissolved Solids Range: 0.0 to 200000 µS/cm
- Conductivity Accuracy: 2 ±% Full Scale
- Display Type: Analog Meter
- Electrical Output: Analog Voltage Output
-
Supplier: Myron L Company
Description: increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface
- Conductivity / Dissolved Solids Range: 0.0 to 200000 µS/cm
- Conductivity Accuracy: 2 ±% Full Scale
- Display Type: Analog Meter
- Electrical Output: Analog Voltage Output
-
Supplier: Myron L Company
Description: increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface
- Conductivity / Dissolved Solids Range: 0.0 to 200000 µS/cm
- Conductivity Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Voltage Output
-
Supplier: Myron L Company
Description: increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface
- Conductivity / Dissolved Solids Range: 0.0 to 200000 µS/cm
- Conductivity Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Voltage Output
-
Supplier: OMEGA Engineering, Inc.
Description: The PHH-128 indicator combines 5 meters into one easy-to-use wall mounting continuous monitor, featuring a large, duallevel, backlit LCD display. This meter can display the EC/TDS/CF (conductivity factor) of your solution together with the choice of either pH (probe sold
- Battery Powered: Yes
- Conductivity / Dissolved Solids Range: 0.0 to 19.99 µS/cm
- Conductivity Accuracy: 2 ±% Full Scale
- Display Type: Digital Display
-
Supplier: OMEGA Engineering, Inc.
Description: The PHUCN600 Series multi-parameter controller is a microprocessor-based controller capable of measuring one of the following parameters, pH, ORP, or conductivity. When shipped from the factory, the PHUCN600 Series is not set to measure any one parameter.When the PHUCN600 Series is
- Control Signal Output: Current Loop, Switch / Relay Output
- Control Technique: Limit / Set Point Control
- Controller Inputs: DC Voltage Input
- Form Factor: Panel / Chassis Mount
-
Supplier: HORIBA Instruments, Inc.
Description: The HE-480R industrial resistivity meter features the high-precision temperature compensation function. Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields
- Display Type: Digital Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Measures Resistivity: Yes
- Mounting / Environment: In-Situ / Field
-
Supplier: SWAN Analytical USA, INC.
Description: Complete monitoring system for the automatic, continuous measurement of the specific resistivity / specific conductivity in high purity water. Features Complete system mounted on stainless steel mounting panel Transmitter AMI Rescon in a rugged aluminum
- Conductivity / Dissolved Solids Range: 0.0100 to 1000 µS/cm
- Conductivity Accuracy: 0.5000 to 1 ±% Full Scale
- Control Relays: 2
- Display Type: Digital Display
-
Supplier: ABB Measurement & Analytics
Description: wherever and whenever you need it. Plug-and-play universal modular design 'Easy Setup' menus provide step-by-step guidance Multi-level security access prevents unauthorized modification of process control data Secure data archiving to an SD card Direct connection to your smart device HART, Ethernet,
- Display Type: Video Display
- Electrical Output: Analog Voltage Output, Switch / Alarm Relay Output
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: Panel
-
Supplier: SWAN Analytical USA, INC.
Description: The portable AMI INSPECTOR is a complete monitoring system mounted on a small panel with supporting stand and a rechargeable battery for stand-alone operation, designed as an inspection equipment for quality assurance of online, resistivity process monitors. Features Resistivity
- Battery Powered: Yes
- Control Relays: 2
- Display Type: Digital Display
- Electrical Output: Analog Current Output
-
Description: The W100P series provide an economical and reliable way to keep your water treatment program under control. Key Features: Large display with icon based programming makes setup easy Compact ¼ DIN panel mount enclosure Universal sensor input
- Control Signal Output: Current Loop, Switch / Relay Output, Pulse / Frequency
- Control Technique: Limit / Set Point Control, PID Control
- Controller Inputs: Serial / Digital Input
- Form Factor: DIN Rail
-
Supplier: HORIBA Instruments, Inc.
Description: -frie ndly product that uses lead-free solder for mounting chips on the PCB. Precise measurement of low HF concentrations 5 types of measurement available HF, HCl & NH3 concentrations, conductivity, and temperature The analog output range can
- Analog Input Type: DC Voltage
- Depth: 115 mm
- Display Technology: LED
- Display Type: Combination
-
Supplier: ABB Measurement & Analytics
Description: instruments enable continuous measurements of one or two dissolved oxygen points with simultaneous local display and retransmission. AX48x is used with 9408 Series immersion, submersion and self-cleaning floating-ball sensors providing measurements with exceptional accuracy and performance. AX400
- Accuracy: 0.1000 ppm
- Control Relays: 3
- Controller Functionality: Yes
- Dissolved O2 Range: 0.0 to 25 ppm
-
Supplier: Siemens Process Instrumentation
Description: conductivity Cost-effective solution, backward compatible with older existing flowmeter sensors (MAG 5100W) Equipped with a large, rotatable, backlit 14-digit graphical display for optimal visibility in all mounting positions Easy programming and commissioning with menu and
- Computer Controllable: Yes
- Display: Digital Display
- Electrical Output: Analog Current
- Flow Meter Type: Velocity Flow Meter
-
Supplier: ABB Measurement & Analytics
Description: H, ORP, conductivity or EZlink (pH/ORP only) digital measurements Plug-and-play sensor and communication modules minimize stock holding and maximize operation uptime available with PROFIBUS™ PA, FOUNDATION™ Fieldbus™ or HART™ communications Data
- Conductivity Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Switch / Alarm Relay Output
- Measures Conductivity / Dissolved Solids: Yes
-
Supplier: optek-Danulat, Inc.
Description: The CONTROL 200 electrochemical converter is designed for continuous monitoring and control of pH and conductivity. The C200 series is available either as a single input (pH or conductivity) or dual input (pH and/or conductivity) converter. Operation and programming is simple,
- Conductivity / Dissolved Solids Range: 1 to 850000 µS/cm
- Control Relays: 5
- Controller Functionality: Yes
- Display Type: Video Display
-
Supplier: Hach
Description: includes chlorine, turbidity, pH, conductivity, pressure and temperature instruments with SC1000 digital controller and a calibration shelf, making routine maintenance convenient. The panel is also available with the reagent less CL10 chlorine analyzer in place of the CL17 and the
- Built-in or Self-calibration: Yes
- Display Type: Digital Display
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: Panel
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 1066 loop-powered transmitter measures pH, ORP, conductivity, resistivity, oxygen, free chlorine, total chlorine, monochloramine and ozone serving a wide range of liquid analytical applications. Digital communications – HART® version 7 and FOUNDATION® fieldbus communication
- Conductivity / Dissolved Solids Range: 0.0100 to 1.00E6 µS/cm
- Conductivity Accuracy: 0.6000 to 4 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 5081 family of transmitters can be used to measure pH, ORP, conductivity (using either contacting or toroidal sensors), resistivity, oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone in a variety of process liquids. Choice of communication protocol: HART® or
- Conductivity / Dissolved Solids Range: 10 to 20000 µS/cm
- Conductivity Accuracy: 1 to 2 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 1056 dual-input analyzer offers single or dual sensor input with an unrestricted choice of dual measurements thus reducing the cost per loop and saving panel space. The unit has a choice of HART and Profibus DP digital communications. It features a large back-lit display that has
- Conductivity / Dissolved Solids Range: 0.0 to 600000 µS/cm
- Conductivity Accuracy: 0.6000 to 10 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
-
Supplier: Emerson Automation Solutions – Rosemount
Description: MULTI-PARAMETER INSTRUMENT – up to three inputs: Choose pH/ORP/ISE or Contacting Conductivity/Resisti vity, in any combination LARGE DISPLAY – easy-to-read process measurements EASY TO INSTALL – modular boards, removable
- Conductivity / Dissolved Solids Range: 0.0100 to 600000 µS/cm
- Control Relays: 4
- Display Type: Video Display
- Electrical Output: Analog Current Output
Find Suppliers by Category Top
Featured Products Top
-
enclosure while being a compact size at 6x4.8 inches (15.2x122mm). They are suitable for panel, bench or surface mounting. Additional options include a 3 Sensor input, a 3 Range switch (both installed separately from the monitor/controller) and a Remote Alarm - RA™. Custom and OEM Models available. Contact them with your requirements. (read more)
Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
above/below setpoint readings. All 750 Series II models feature an IP65/NEMA 4X water resistant and corrosion-proof rated enclosure while being a compact size at 6x4.8 inches (15.2x122mm). They are suitable for panel, bench or surface mounting. Additional options include a 3 Sensor input (read more)
Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
., they are suitable for panel, bench or surface mounting. Additional options include a 3 Sensor Input Switch and/or a 3 Range Switch and a Remote Alarm™ model RA. (read more)
Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
/below setpoint readings. All 750 Series II models feature an IP65/NEMA 4X water resistant and corrosion-proof rated enclosure while being a compact size at 6x4.8 inches (15.2x122 mm). They are suitable for panel, bench or surface mounting. Accessories include a 3 Sensor input, a 3 (read more)
Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
Altech digital panel meters deliver precise voltage, current, and process signal measurement with modular LED displays and DIN panel mounting for clear system (read more)
Browse Digital Panel Meters Datasheets for Altech Corp. -
Contacts Options, Front Panel Mounted LED Output Indicator, Temperature monitor, handles, chassis slides, Digital Voltage and Current Meters and more. Linear operation minimizes output noise so these power supplies are ideal for use in test equipment, analog systems, controls, medical (read more)
Browse Power Supplies Datasheets for Acopian Power Supplies -
. These include: Cellphone based Smart UV Checker Panel Mounted Units (read more)
Browse UV Sensors Datasheets for Electro Optical Components, Inc. -
) Fused distribution panels Alarm circuits e.g. Form C module fail alarm Low battery disconnect, battery temperature compensation Meters: digital or analogue for volt and/or current LED indicators Front panel adjustment RoHS compliance (read more)
Browse Power Supplies Datasheets for ABSOPULSE Electronics Ltd. -
The Superdew?3?WP from Shaw Moisture Meters is a robust inline dewpoint hygrometer engineered for precise trace moisture measurement in process gases and compressed air. Designed for demanding industrial environments, it is housed in a wall?mount, weatherproof IP65 (NEMA (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters -
-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C. PCE-TDS 200 L (read more)
Browse Ultrasonic Flow Meters Datasheets for PCE Instruments / PCE Americas Inc.
More Information Top
-
An aerial survey of radioactivity associated with Atomic Energy plants
This meter is mounted on the same panel as the conductivity re- .
-
Control of diabetes insipidus by continuous monitoring of the electrical conductivity of the urine with a simple device
The panel meter is inversely mounted so that it does not indicate the meas- ured resistance but the conductivity .
Indicates content that may require registration and/or purchase.