Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Angst+Pfister Sensors and Power
Description: The PAROX 1200 paramagnetic oxygen gas sensor module is designed for incorporation in your analyzer-systems with very low cross-sensitivity, long lifetime and very stable long term performance. The PAROX 1200 (earlier known as OXYPA) paramagnetic oxygen
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: SAE International
Description: sensors are divided into expendable and non-expendable sensors. Expendable sensors are based on electrochemical properties, whereas non-expendable sensors rely on paramagnetic, photo-acoustic, electromagnetic, and laser spectroscopy properties.
-
Supplier: Panametrics
Description: Panametrics’ new XMO2pro oxygen analyzer is the ultimate choice for highly accurate oxygen measurements in harsh environment industrial and oil & gas applications. Thanks to the perfectly matched interaction between the paramagnetic oxygen property and temperature, the
- Response Time: 15 seconds
- Operating Temperature: -4 to 131 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
-
Supplier: ABB Measurement & Analytics
Description: technology Intuitiv operation via five buttons UV photometer Infrared photometer Paramagnetic oxygen analyzer Electrochemical oxygen sensor Thermal conductivity analyzer Trace oxygen analyzer Flame Ionization Detector Extensive self-diagnosis functions Internal
- Operating Temperature: 41 to 122 F
- Operating Humidity: 50 %
- Response Time: 2.5 seconds
- Measurement Type: %Volume, Trace
-
Supplier: Fuji Electric Corp. of America
Description: oxygen sensor available
- Operating Temperature: 41 to 104 F
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms
- Gas Types: Carbon Dioxide (CO2), Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Oxygen (O2)
-
Supplier: Emerson Automation Solutions – Rosemount
Description: visible (NDIR/UV/VIS) photometry, paramagnetic and electrochemical oxygen, and thermal conductivity sensor technologies for consistent, precise process gas measurement. X-STREAM analyzers measure up to four components in various combinations, and its versatile design allows
- Number of Channels: 4
- Response Time: 30 seconds
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Siemens Analytical Products
Description: paramagnetic alternating pressure method. This guarantees perfect linearity and allows parameterization of minimal measuring ranges of 0 to 0.5 % (detection limit 50 ppm) up to 0 to 100% in a single device, and even 99,5 to 100%. The sensor in the detector does not come into contact
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
-
Supplier: Nova Analytical Systems Inc.
Description: as it reaches a limit. Next, the dried sample gas is filtered again and then flows through a PTFE liquid block, calibration gas valves, pressure regulator, flow meter then on to the gas detector.The 7200-1-F1 analyzer features an electrochemical sensor, paramagnetic sensor or
- Response Time: 20 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 5 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Rosemount Analytical’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies (pO2/eO2), trace
- Number of Channels: 5
- Response Time: 19.99999999999998 seconds
- Operating Temperature: 41 to 104 F
- Operating Humidity: 0 to 90 %
-
Supplier: Siemens Process Instrumentation
Description: an innovative multi-component gas analyzer which can be equipped with the following sensors: IR detector for IR-active gases, UV photometer for UV-active gases, H2S sensor (electrochemical), O2 sensor (electrochemical or paramagnetic), and used accordingly in numerous
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2), Sulfur Hexafluoride (SF6), Toxic Gas
Find Suppliers by Category Top
Featured Products Top
-
maintenance and ease of operation. Gas sensor technologies that can be used include: NDIR & NDUV Electrochemical Photoacoustic Paramagnetic Zirconia Photoionization Radiation Detection Gas Filter (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc.
Conduct Research Top
-
Selecting a Low-Maintenance Sensor for Safety Monitoring of Oxygen and Carbon Monoxide Levels in Industrial Processes and Environments
For safety, legal, and compliance reasons industrial plants must monitor oxygen (O2) and carbon monoxide (CO) levels in processes and structures. Traditional technologies for. detecting these gases include paramagnetic, nondispersive infrared, electro-chemical cell, and zirconium oxide sensors
More Information Top
-
Gas measuring technique in theory and practice
Paramagnetic oxygen sensor .
-
Highly accurate measurement of oxygen using a paramagnetic gas sensor
The method employed uses an auto-null ‘dumbbell’ type paramagnetic oxygen sensor , which has high resolution (10 µmol mol−1 ) . and excellent linearity.
-
LTCC: a fascinating technology platform for miniaturized devices
Keywords: Low Temperature Co-fired Ceramics, multilayer technology, thin film technology, molybdenum metallization, paramagnetic oxygen sensor , injection quantity sensor.
-
A differential paramagnetic sensor for breath-by-breath oximetry
The operating principles of a fast paramagnetic oxygen sensor are described in detail.
-
Nanofiber- based paramagnetic probes for rapid, real- time biomedical oximetry
Lithium octa-n-butoxynaphthalocyanine (LiNc- BuO), an excellent paramagnetic oxygen sensor , was successfully encapsulated in 300–500 nm diameter fibers consisting of a core of polydimethylsiloxane (PDMS) and a shell of polycaprolactone (PCL) by electrospinning.
-
Respiratory Disease and its Management
Paramagnetic Oxygen Sensor .
-
Assessment of tumor oxygenation by electron paramagnetic resonance: principles and applications
The different types of paramagnetic oxygen sensors will be presented, as well as the methods for recording the information (EPR spectroscopy, EPR imaging, dynamic nuclear polarization).
-
The inspiratory to end-tidal oxygen difference during exercise
During the last decade it has become possible to ana- lyze the end-tidal oxygen concentration (PET02) breath by breath thanks to fast response paramagnetic oxygen sensors [1, 2].
-
MEMS Based Paramagnetic Oxygen Measurement
For industrial applications so-called magneto- mechanical paramagnetic oxygen sensors are widely used.
-
Techniques for oxygen transfer measurement in bioreactors: a review
Since this sensor measures the partial pressure of oxygen directly, it is essential to compensate for ambient pressure.65 The paramagnetic oxygen sensor is a highly accurate mea- surement technique for oxygen concentration.
Indicates content that may require registration and/or purchase.