Supplier: Accuris
Description: Operational Guide for Direct Current Plasma Emission Spectrometer Analysis
-
Supplier: Accuris
Description: Standard Practice for Describing and Specifying Inductively-Coupled Plasma Optical Emission Spectrometers
-
Supplier: Accuris
Description: Standard Practice for Describing and Specifying Inductively Coupled Plasma Atomic Emission Spectrometers
-
-
Supplier: Accuris
Description: STANDARD PRACTICE FOR DESCRIBING AND SPECIFYING A DIRECT CURRENT PLASMA ATOMIC EMISSION SPECTROMETER
-
Supplier: Hitachi High-Tech America
Description: The FM EXPERT is the next level optical emission spectrometer, combining superior analytical performance with a compact size. Its large wavelength range is ideal for the analysis of all relevant elements in metals quality assurance and production process control. The FM EXPERT also
- Detector: Solid State (CCD)
- Excitation Source: Spark or Arc
-
Supplier: ASTM International
Description: 1.1 This practice describes the components of an inductively coupled plasma atomic emission spectrometer (ICP-AES) that are basic to its operation and to the quality of its performance. This practice identifies critical factors affecting accuracy, precision, and sensitivity. It
-
Supplier: ASTM International
Description: 1.1 This practice describes the components of an inductively-coupled plasma optical emission spectrometer that are basic to its operation and to the quality of its performance. It is not the intent of this practice to specify component tolerances or performance criteria, since
-
Supplier: ASTM International
Description: 1.1 This practice describes the components of a direct current plasma (DCP) atomic emission spectrometer. This practice does not attempt to specify component tolerances or performance criteria. This practice does, however, attempt to identify critical factors affecting bias,
-
Supplier: LECO Corporation
Description: Glow Discharge Spectrometry utilizes a low-pressure, non-thermal process in which material is uniformly sputtered from the sample surface by a stream of argon ions. The sputtered material is then atomized and excited in a low-pressure plasma discharge, away from the sample surface. The GDS850
- Spectral / Wavelength Range: 120 to 800 nm
- Remote Interface: Application Software Included, Computer Interface
- Display: None
- Detector: Solid State (CCD)
-
Supplier: ASTM International
Description: 1.1 This practice describes the components of a direct-current-plasma (DCP) optical emission spectrometer. This practice does not attempt to specify component tolerances or performance criteria. This practice does, however, attempt to identify critical factors affecting bias,
-
Supplier: CSA Group
Description: coupled plasma – optical emission spectrometry and is applicable to leathers which are expected to have chromic oxide contents in excess of 1 mg/kg. Two techniques for the preparation of the solution to be analysed are included. In the case of dispute, the wet oxidation technique is to
-
Description: coupled plasma – optical emission spectrometry and is applicable to leathers which are expected to have chromic oxide contents in excess of 1 mg/kg. Two techniques for the preparation of the solution to be analysed are included. In the case of dispute, the wet oxidation technique is to
-
Supplier: Bruker Corporation
Description: but is focused to a microscopic point on the sample to generate the plasma. In this plasma, the matter constituting the samples is dissociated into atoms (atomization) and partially ionized. Those atoms and ions will be excited (transition of electrons from lower to higher energy
- Excitation Source: Laser-Induced Breakdown
- General Features: Portable
- Detector: Solid State (CCD)
-
Supplier: StellarNet, Inc.
Description: hub allowing simple configurations for dual and multi-beam applications in chemistry, spectroradiometry, and PORTA-LIBS. Additional BLUE-Wave measurement applications include emission wavelength monitoring /characterization of tunable lasers or LED’s and other sources such as elemental
- Spectral / Wavelength Range: 500 to 1,150 nm
- Resolution: 0.8 nm
- Remote Interface: Application Software Included, Computer Interface, Serial Interface
- Features: Data Processing Functions, Dispersive, On-line Monitoring & Process Control
-
Supplier: StellarNet, Inc.
Description: hub allowing simple configurations for dual and multi-beam applications in chemistry, spectroradiometry, and PORTA-LIBS. Additional BLUE-Wave measurement applications include emission wavelength monitoring /characterization of tunable lasers or LED’s and other sources such as elemental
- Wavelength Range: 200 to 1,150 nm
- Spectral Resolution: 0.2 nm
- Stray Light: 0.1 %
- Computer Interface Options: Application Software Included, Computer Interface, Serial Interface
-
Supplier: Rigaku Corporation
Description: with inductively coupled plasma optical emission spectroscopy (ICP-OES), NANOHUNTER provides part-per-billion (PPB) level detection limits in a fully automated tool. Direct measurement of solids and powders provides freedom from complex sample digestion or preparation and makes this
- Operating Temperature: 59 to 82.4 F
- Operating Humidity: 0 to 60 %
- Remote Interface: Computer Interface
- Sample Type: Liquids, Solids
-
Description: Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled
-
Supplier: UL Standards & Engagement
Description: atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers and mass spectrometers, all with thermal atomization and ionization
-
Supplier: AENOR
Description: Leather - Chemical determination of chromic oxide content - Part 4: Quantification by inductively coupled plasma - optical emission spectrometer (ICP-OES) (ISO 5398-4:2007)
-
Supplier: CSA Group
Description: text by the following: This part of IEC 61010 applies to electrically powered laboratory atomic spectrometers with thermal atomization. NOTE 1 Examples include atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively
-
Supplier: Element Materials Technology
Description: Portable X-Ray Fluorescent Analyzer Optical Emission Spectroscopy (OES) Portable Optical Emission Spectroscopy (OES) Atomic Absorption (AA) Analyzers Inductively Coupled Plasma (ICP) Combustion/IR Analyzers Gas Chromatography/Mass Spectrometry (GC/MS) Analyzers Glow Discharge
- Standards (Test / Certify To): ASME, ASTM, AWS, EPA, MIL-SPEC, OEM Specific, RoHS
- Test Methods: Acoustic Microscopy (SAM), Atomic Absorption Spectroscopy (AA), Auger Spectroscopy (AES), Chemical Extraction, Chromatography (GC, HPLC, etc.), Combustion Analysis, Diffraction (X-ray, Electron, etc.), Inductively Coupled Plasma (ICP / LA-ICP), Infrared Spectroscopy (FTIR, etc.), Mass Spectroscopy
- Materials: Adhesives / Sealants, Air, Ceramics / Glass, Chemicals, Coatings, Composites, Concrete / Mortar, Gases, Heavy Metals (Lead, Chromium, etc.), Inorganics, Metals, Nanomaterials, Paper, Petroleum Fluids (Oil, Fuel, Distillates), Plastic / Rubber, Polymers / Organics, Powders, Sediment, Soil, Textiles,
- Industry: Aerospace / Aviation, Automotive, Chemical / Material Processing, Food / Beverage, Health Care / Medical, Legal / Forensics, Marine, Military, Nuclear / Utility, Packaging, Pharmaceutical / Biotech, Piping / Pressure Vessel, Semiconductors / Electronics, Structural / Construction
-
Description: IEC TS 62607-4-7:2018 provides a method for the determination of magnetic impurities in anode nanomaterials for energy storage devices using an Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES), including test overview, reagents, apparatus, test procedures, test
-
Supplier: CSA Group
Description: IEC TS 62607-4-7:2018 provides a method for the determination of magnetic impurities in anode nanomaterials for energy storage devices using an Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES), including test overview, reagents, apparatus, test procedures, test
-
Supplier: StellarNet, Inc.
Description: hub allowing simple configurations for dual and multi-beam applications in chemistry, spectroradiometry, and PORTA-LIBS. Additional BLUE-Wave measurement applications include emission wavelength monitoring /characterization of tunable lasers or LED’s and other sources such as elemental
- Wavelength Range: 350 to 1,150 nm
- Mounting / Environment: In-situ / Field, Lab / Benchtop, Portable
- Display Type: Video
-
Description: wet chemical methods are used, based on aqua regia extracts, in combination with optical or mass spectrometric (MS) methods like atomic absorption spectrometry (AAS), inductively coupled plasma/optical emission spectrometry (ICP/OES) or ICP/MS.
-
Supplier: Leybold USA Inc.
Description: available Heat treatment & plasma processes In heat treatment furnaces and plasma processes, vacuum pump technology needs to perform reliably while exposed to difficult processes. SOGEVAC NEO D advantages: Rugged industrial design with oil filter No external exhaust filter required
- Mechanical: Rotary Vane
-
Supplier: Leybold USA Inc.
Description: available Heat treatment & plasma processes In heat treatment furnaces and plasma processes, vacuum pump technology needs to perform reliably while exposed to difficult processes. SOGEVAC NEO D advantages: Rugged industrial design with oil filter No external exhaust filter required
- Mechanical: Rotary Vane
Find Suppliers by Category Top
More Information Top
-
The Use of Modern Atomic Spectroscopy in Industrial Analysis
During the late 1960s and early 1970s, a new family of instruments became available, plasma emission spectrometers [1,2].
-
Subject Index
Open insulations design for a contained inductively cou- pled plasma/D-C arc atomic emis- sion spectrometer, 66-70 inductively coupled plasma emission spectrometer system in a separations process plant laboratory, 41-59 modification of an inductively coupled plasma atomic emission spectrom- eter…
-
Environmental Biotechnology and Materials Engineering (2013)
The structure and size of nano-HA powders was investigated by X-ray diffraction (XRD) and the concentrations of Cu2+and Pb2+ in aqueous solutions were tested by inductively coupled plasma emission spectrometer .
-
Dissolution Kinetics of a Bioactive Glass by Continuous Measurement
An inductively coupled plasma emission spectrometer was utilized to analyze changes in the solution composition due to the glass dissolution.
-
Applied Mechanics and Mechanical Engineering II
At present, the emission spectrometer used in oil monitoring are mainly two kinds, namely, spark-electrode emission spectrometer and plasma emission spectrometer .
-
A Consumer's Guide to Archaeological Science
Plasma emission spectrometers encompass the entire UV and visible spectrum, from 170 to 800 nm (Fig. 2.2).
Indicates content that may require registration and/or purchase.