Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable flue gas analyzer adopts the unique long life time electrochemical techniques to measure the CO ,CO2 ,O2 ,SO2 ,NO2 ,NO and other gases in flue gas and to figure out excess air coefficient. This product has high precision, small volume, it is convenient to carry,
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 5000 Series Portable Flue Gas analyzer has been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The 5000 uses customer replaceable sensors which respond quickly to the O2, CO2, SO2, CO,
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: ABB Measurement & Analytics
Description: N2O/CO Analyzer is designed for many demanding applications including trace-gas (air quality) monitoring (e.g., GAW stations), eddy-correlation flux measurements, chamber flux measurements, and combustion diagnostics. The Analyzer is particularly well suited for measurements in
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Monoxide (CO), Nitrogen Oxides (NxOx)
-
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 313 Series Portable Flue Gas Analyzer for NO, NO2, or NOx utilizes reliable, stable NO and/or NO2 sensors which respond quickly to the NO or NO2 present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 312 Series Portable Flue Gas Analyzer for NOX utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOX found in flue gases or engine exhaust (except
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Process Sensing Technologies USA
Description: Rechargeable battery pack (Optional) Integral flow meter for positive pressure sample flow indication LCD + 4 button HMI Lightweight, rugged and portable 2 and 3 sensor option available Analogue output per sensorApplications: Gas generation (oxygen / nitrogen) Pharmaceutical
- Operating Humidity: 0 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Mounting Type: Portable
-
Supplier: Analytical Industries Inc.
Description: Accessories also available below: 1-8 Tube to BC Restrictor 1 LPM Adapter Sensor Manifold Sample Tubing Battery Assembly Nut Replacement Power Cord Lighter Plug Power Cord 1/8 Tube to Dome Adapter Overview A portable Trimix Analyzer designed to ensure the correct mix of helium, oxygen
- Instrument Type: Analyzer
- Display: Digital
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 362 Series are portable analyzers that can provide a detailed analysis of flue gas composition. They have been designed to be accurate, reliable, and easy to use and maintain. Model 362 has customer-replaceable sensors, which respond quickly to the O2, CO, and NOx
- Response Time: 20 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
-
Supplier: Bacharach, Inc.
Description: spot-checking and tuning your engines with the high-range CO sensor and available sample conditioner. Whether it's boiler combustion or emissions testing of your natural gas, stationary genset or mobile fleet vehicles, monitoring your emissions is fast, easy and accurate. Users have the
- Operating Temperature: 32 to 113 F
- Operating Humidity: 15 to 90 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
-
Supplier: Process Sensing Technologies USA
Description: A portable Trimix Analyzer designed to ensure the correct mix of helium, oxygen and nitrogen for technical diving. This easy-to-operate diving instrument automatically corrects for environmental conditions, eliminating the risk of errors from manual calculations. This will help
- Measurement Type: %Volume
- Instrument Type: Analyzer
- Display: Digital
- Gas Types: Oxygen (O2)
-
Supplier: COSA Xentaur Corporation
Description: The COSA 707 is a hand held multigas analyzer for industrial and combustion processes. The COSA 707 is an easy to hold, hand-held emissions analyzers capable of measuring up to seven different gases. The emissions analyzer can be equipped with up to 6 electrochemical sensors and
- Operating Temperature: 41 to 113 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
-
Supplier: ABB Measurement & Analytics
Description: This technique is fast, accurate over a broad measurement range and offers outstanding reproducibility. The AlSCANTM is recognized by the industry with more than 400 units sold worldwide. The AlSCANTM hydrogen analyzer is portable and designed to survive the severe plant environment.
- Sample Form: Gaseous Samples
- Elements Analyzed: Hydrogen (H)
- Analysis Method / Detection Technology: Thermal Conductivity Detector
-
Supplier: Oneida Research Services, Inc.
Description: With the IVA® Model 210s Internal Vapor Analyzer, you can perform package moisture and gas analysis, on-site at your facility. This is a user-friendly test system for monitoring the quality of your hermetic packaging processes. IVA® Technology was invented by ORS and offers the most
- Application: Ambient Air Monitoring, Confined Space Monitoring
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Hydrogen (H2), Nitrogen Dioxide (NO2), Oxygen (O2), Water Vapor
- Features: Controller, Data Logger, Other, Self Calibration
-
Supplier: Accuris
Description: Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR DETERMINATION OF NITROGEN OXIDES, CARBON MONOXIDE, AND OXYGEN CONCENTRATIONS IN EMISSIONS FROM NATURAL GAS-FIRED RECIPROCATING ENGINES, COMBUSTION TURBINES, BOILERS, AND PROCESS HEATERS USING PORTABLE ANALYZERS
-
Supplier: Honeywell Analytics, Inc.
Description: A fast response device detecting down to ppb of toxic gases, providing physical evidence of a gas event. This use-anywhere, fast response monitor is specific to your target gas only. Until now, the big concern with basic units for toxic gas monitoring was that environmental
- Operating Temperature: 32 to 104 F
- Response Time: 10.00000000000002 seconds
- Application: Ambient Air Monitoring, Process Gas
- Gas Types: Ammonia (NH3), Arsine (AsH3), Bromine (Br2), Chlorine (Cl2), Chlorine Dioxide (ClO2), Combustible Gas, Diborane (B2H6), Germane (GeH4), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF),
-
Description: confident in our factory calibration that our customers need never calibrate the NDIR analyzer again. The Andros 6511 is designed to meet and exceed performance requirements for portable or fixed leak detectors of toxics or combustibles. High Stability: rapid warm-up The enhanced
- Response Time: 40.00000000000002 seconds
- Operating Temperature: 32 to 158 F
- Operating Humidity: 95 %
- Measurement Type: %Volume, Trace
-
Supplier: CO2Meter.com
Description: while giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analyzer's. Features Accurate, Quality EC sensor Low Cross-Sensitivity across multiple
- Gas Types: Nitric Oxide (NO)
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of nitrogen oxides (NO and NO2), carbon monoxide (CO), and oxygen (O2) concentrations in controlled and uncontrolled emissions from natural gas-fired reciprocating engines, combustion turbines, boilers, and process heaters using
-
Supplier: CO2Meter.com
Description: ensures that your DO analyzer is always ready for use. The optical oxygen sensor is not affected by other gases including nitrogen or carbon dioxide. Measurements are taken in seconds. The data can be logged to the internal memory and downloaded via USB. A micro-pump inside this
- Dissolved O2 Range: 0 to 2 ppm
- Accuracy: 20,000 ppm
- Form Factor: Modular
Find Suppliers by Category Top
Featured Products Top
-
Aii’s portable diving mix analyzers are designed to measure oxygen concentration in diving gas mixtures, supporting safe dive planning and gas verification. Compact and easy to use, they allow divers to confirm oxygen levels before use (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII’s premium portable O? analyzers are engineered for applications where performance, reliability, and advanced functionality are essential. These instruments deliver accurate oxygen measurement with enhanced durability and user-focused design (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII premium portable oxygen analyzers deliver accurate and stable oxygen measurement in a robust, portable format. Designed for professional use, they support reliable analysis in a wide range of operating conditions (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII’s portable O? analyzer range provides accurate oxygen measurement in a variety of portable and field-based applications. Designed for ease of use and dependable performance, these analyzers support oxygen verification wherever mobility is required (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
The Palm CO Analyzer is a compact, portable instrument designed to detect carbon monoxide contamination in breathing air and compressed gas systems. It provides fast, reliable CO measurement to help prevent exposure to dangerous carbon monoxide levels (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
and companies. Before making the switch to generating nitrogen, NW Wine Company had stored nitrogen in dewars. Dewars contain liquid nitrogen that is managed by a third-party gas company who replaces empty dewars with full ones. Depending on levels of nitrogen consumption, a dewar may last as (read more)
Browse Gas Generation Equipment Datasheets for Rogers Machinery Company, Inc. -
Nitrogen generation system upgrade helped a Pacific Northwest brewery save thousands and increase production efficiency.
(read more)
Browse Gas Generation Equipment Datasheets for Rogers Machinery Company, Inc. -
AII’s handheld oxygen analyzers for medical gases are designed to provide fast, accurate measurement of oxygen concentration in medical environments. Portable and easy to use, these analyzers support verification of oxygen purity in medical gas pipelines (read more)
Browse Gas Sensors Datasheets for Analytical Industries Inc. -
Analytical Industries Inc. oxygen monitors for glove boxes and nitrogen generators are engineered to measure low oxygen concentrations in inert and controlled atmosphere systems. They support precise monitoring of oxygen levels to maintain product quality (read more)
Browse Gas Transmitters Datasheets for Analytical Industries Inc. -
The CalorVal BTU Analyzer continuously measures the heating value (Calorific Value) of gaseous streams of industrial processes. Real time: Direct measure of calorific value Fast: Less than 3.5 seconds cell response time Universal: Highly uniform response to a (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp.
Conduct Research Top
-
The Ups and Downs of Taking the Bus
possible, but in specific instances, conventional instrumentation was required. Fermentation exhaust gas monitoring is performed using PerkinElmer Model 1100 medical gas analyzers (Figure 3, right). These analyzers measure carbon dioxide, oxygen, and nitrogen in the fermentation exhaust gases
More Information Top
-
Residential commissioning: a review of related literature
In other cases, the sampling equipment can be very sophisticated and expensive (e.g. portable gas analyzers for nitrogen oxides), which may reduce the likelihood that the technique would be used during commissioning (except perhaps by an IAQ commissioning specialist).
-
Lead Sulfide Semiconductor Sensing Element for Nitrogen Oxide Gas Analyzers
The sensing ele- ments were intended for use in automatic portable gas analyzers for detecting nitrogen oxides in flue gases of electric power installations at thermoelectric power sta- tions.
-
Assessment of the variability in response of radish and brinjal at biochemical and physiological levels under similar ozone exposure conditions
Air quality monitoring for nitrogen dioxide (NO2) was done by portable gas analyzer using wet chemistry methodology (Merrymann et al. 1973).
-
Advances in Thermofluids
Air test for temperature, RH, carbon dioxide, sulfur dioxide, nitrogen dioxide and nitrogen oxide were taken with the portable gas analyzer Model Testo 350XL.
-
Federal Register > Thursday, August 27, 2015 > [80 FR 52100] Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills
In proposed 40 CFR part 60, subpart Cf, the EPA has not listed portable gas composition analyzers for determining oxygen or nitrogen levels.
-
Relationship between nitrogenous species in coals and volatile nitrogen‐containing yields during pyrolysis
A GASMET FTIR D×4000 portable gas analyzer was used to determine the nitrogen -containing com- pounds in the pyrolysis product gases on line.
-
http://www.scirp.org/journal/PaperDownload.aspx?DOI=10.4236/ojss.2012.22022
Leaf nitrogen use efficiency values were calculated from leaf CO2 exchange measurements of fully expanded upper canopy leaves dur- ing dry periods of 5 - 8 month old plants using portable infrared gas analyzers , and total leaf nitrogen content.
-
Development of fuzzy based methodology to commission co-combustion of unprepared biomass on chain grate stoker fired boilers
The flue gas composition was analysed, with a Testo 33 portable flue gas analyser , for oxygen concentration, carbon monoxide, nitrogen oxi- des and the flue gas temperature with each of these parameters being recorded every 30 s.
-
Methods of reducing emissions of nitrogen oxides at thermal power plants burning solid domestic waste
During the tests the characteristics of the furnace operat- ing regimes were recorded as functions of the secondary air feed variants and data on the oxygen and nitrogen oxides contents obtained by standard monitoring and from measure- ments with portable gas analyzers .
-
International Energy Conversion Engineering Conference (IECEC) > Combustion Properties of Spray Flames of Butanol/Jet A Blends at a Lean Global Equivalence Rat...
Measurements of the volumetric concentration of CO, CO2 and NOx in the exhaust were carried out using a portable flue gas analyzer for oxygen, carbon monoxide, carbon dioxide and oxides of nitrogen .
Indicates content that may require registration and/or purchase.