Supplier: ENCON Evaporators
Description: When activated, the burner(s) will fire into the cylindrical combustion chamber of the heat exchanger. The hot gases travel past the vertical tubes inside the heat exchanger until they reach the insulated chimney outside the evaporator tank.
- Evaporation Rate: 35 GPH
- Feed Tank Capacity: 330 gallons
- Operating Temperature: 232.22222222222223 C
- Features: Display and Interface, Other
-
Supplier: ENCON Evaporators
Description: When activated, the burner(s) will fire into the cylindrical combustion chamber of the heat exchanger. The hot gases travel past the vertical tubes inside the heat exchanger until they reach the insulated chimney outside the evaporator tank.
- Evaporation Rate: 72 GPH
- Feed Tank Capacity: 420 gallons
- Operating Temperature: 232.22222222222223 C
- Features: Display and Interface
-
Supplier: Samsco Corporation
Description: Energy is the single largest component of operating costs in many wastewater treatment systems, and particularly is this so with distillation, where it generally accounts for 50-70% of total operating costs. The Samsco EnviroStill MVR Evaporator uses metal plate heat exchange
- Evaporation Rate: 500 GPH
- Application: Distillation, Waste Water Treatment
- Power Source: Electric, Steam
- Features: Mechanical Vapor Recompression, Other
-
-
Supplier: Samsco Corporation
Description: The SWE-II uses a system design that provides consistent operation, minimal cleanout, high efficiency and ease of maintenance.
- Evaporation Rate: 18 GPH
- Feed Tank Capacity: 164 gallons
- Features: Display and Interface
- Application: Distillation, Waste Water Treatment
-
Supplier: Proceco Ltd.
Description: As part of Proceco's integrated systems approach, we offer a variety of technologies to deal with industrial wastewater treatment ensuring a turnkey solution to your water-based parts cleaning or surface finishing application. Industrial wastewater treatment systems are designed to
- Evaporation Rate: 133.333333333333 GPH
- Application: Coating / Etching, Distillation, Liquid Recycling, Plastics Processing, Semiconductor Manufacturing, Waste Water Treatment
- Features: Display and Interface, Mechanical Vapor Recompression, Other
- Power Source: Electric
-
Supplier: ENCON Evaporators
Description: The ENCON MVC Evaporator product line has standard offerings that range in capacity from 40-1800 gallons/hour. These systems operate on electricity and compressed air at a typical operating cost of $0.01-$0.02* per gallon of distilled water. Materials of construction include 316 Stainless
- Evaporation Rate: 1,200 GPH
- Application: Desalinization / Seawater Treatment, Distillation, Waste Water Treatment
- Power Source: Electric
- Features: Mechanical Vapor Recompression, Other
-
Supplier: Samsco Corporation
Description: The Samsco WasteSaver™ is a dual-effect, vacuum distillation evaporator that uses low-pressure steam to evaporate wastewater under vacuum at very low temperature. The steam is then condensed and returned for reuse as clean, distilled water. By evaporating under vacuum, the system can
- Evaporation Rate: 1,500 GPH
- Operating Temperature: 32.22222222222222 to 43.333333333333336 C
- Features: Display and Interface
- Power Source: Electric
-
Supplier: ENCON Evaporators
Description: When activated, the heating element contactors will close and provide power to the heating elements located inside the evaporator tank. The hot water vapor created inside the evaporator tank is drawn through the mist eliminator, up the stack, and is exhausted outside the building.
- Evaporation Rate: 8 GPH
- Feed Tank Capacity: 70 gallons
- Operating Temperature: 232.22222222222223 C
- Features: Display and Interface
-
Supplier: Inproheat Industries Ltd.
Description: water evaporation Crystallization Solution concentration RO Rejects for metallurgical processes (e.g. electrowinning) Water treatment pond water freeze prevention Heating of wastewater in which elevated temperatures are required for treatment operations Other SubCom® also has proven to be a
- Application: Food Processing, Gas Recovery, Liquid Recycling, Oil Refining, Waste Water Treatment
- Type: Forced Circulation / Crystallizer
- Features: Other
- Operation: Production
-
Description: This is a integrated system used for waste water evaporation. Evaporation plants are used as a thermal separation technology, for the concentration or separation of liquid solutions, suspensions and emulsions.
-
Description: SUNKAIER wiped film evaporator (WFE) provides short residence time and open, low pressure drop configuration, allowing continuous, reliable processing of many heat sensitive, viscous, or fouling materials without product degradation. Mechanical Vapour Recompression is an evaporation process
-
Supplier: Pope Scientific, Inc.
Description: falling film stills, rotary evaporators and other equipment, in any processing application where heat-sensitivity is a factor. Pope Short Path/Wiped-Film Stills (WFS) and Wiped-Film Evaporators (WFE) successfully separate volatile from less volatile components with a gentle process
- System Capacity: 23 to 230 kg/hr
- Operating Temperature: 30 to 400 C
- Power Source: Electric
- Application: Food Processing, Pharmaceutical Processing, Research and Development, Solvent Recovery, Waste Water Treatment
Find Suppliers by Category Top
More Information Top
-
Hazardous Waste Code Determinations for the First/Second Stage Sludge Waste Stream (IDCs 001, 002, 800)
Around 1965, an evaporator was installed to augment liquid treatment, including wastewater from solar ponds.
-
Industrial Water Management: A Systems Approach
Electrically driven vapor compression evapora- tors perform the final wastewater concentra- tion, recovering a minimum of go percent as nearly pure condensate for demineralizer feed, and reducing final solar evaporation pond re- quirements by more than go percent compared with a scheme …
-
Chemical Safety Vulnerability Working Group report. Volume 3
It was used as a laundry water feed tank for the Building 774 Evaporator and later as a temporary storage facility for low-levelwastewater beforethe wastewater was moved to the Building 207 A, B, and C Solar Ponds.
-
Bookshelf and Unified Agenda > Department of Energy > Chemical Safety Program > Chemical Safety Vulnerability Working Group Reports > Volume 3 > [FDBKF20031106...
It was used as a Iaundty water feed tank for the Building 774 Evaporator and later as a temporary storage facility for low-level wastewater before the wastewater was moved to the Building 207 A, B, and C Solar Ponds.
-
Water and Sustainability in the 21st Century
… 205 Volume of Retentate............................................................................................................206 Retentate Classification........................................................................................................206 Cleaning Solutions...............................................................................................................206 Waste Stream Reduction Methods............................................................................................206 Concentration by Multiple-Stage Membrane Arrays...............................................................207 Solar Evaporation................................................................................................................207 Falling Film Evaporators ......................................................................................................207 Spray Dryers .......................................................................................................................208 … … Processes ..........209 Discharge to Wastewater Collection System..........................................................................210 Water …
-
Water Encyclopedia 5 Volume Set
Example of water use, wastewater generation, and treatment proposals for raw sugar. happens with boilers purges and acid-caustic solutions used to clean heat transfer surfaces in evaporators and vacuum boiler pans, the most suitable process is to eliminate water by evaporation (preferably solar evaporation, taking advantage of climatic conditions in tropical areas).
-
Water Pollution and Abatement Policy in India
After treating dye bath water by sand and nanofiltrations (NF), the permeate is used in the process for dye bath preparation and the reject of about 20–30 % is sent to multi-effect evaporator (MEE)/ solar evaporation pond (SEP). Wastewaters treated using a sequence of physicochemical and biological unit processes are passed into two stages reverse …
-
Solar evaporation of aqueous wastes from fertilizers/ag-chemical dealerships
Therefore, atmospheric evaporators are economically attractive only when wastewater is preheated in the original process or when low- cost process heat is available. Solar energy repre- sents an excellent source of low-cost heat.
-
RENEWABLE ENERGY AND ENVIRONMENTAL SUSTAINABILITY USING BIOMASS FROM DAIRY AND BEEF ANIMAL PRODUCTION
A solar drying system, which Kolber called a “Smart Evaporator ”, would evaporate any wastewater that is not treated in the covered waste processor and keep the system from overflowing.
-
Solar concentration/destruction of pesticide rinsewater
Therefore, atmospheric evaporators are economically attractive only when wastewater is preheated in the original process or when low-cost process heat is available. Solar energy represents an excellent source of low-cost heat.
Indicates content that may require registration and/or purchase.