Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Agilent Energy & Chemicals - Polymers
Description: We offer a wide range of solid phase extraction (SPE) products in various polarities and chemistries. A broad selection of Bond Elut sorbents is available in cartridge and well plate formats and as bulk sorbents. Frits, adapter caps, empty cartridges for custom packing, and
- Configuration: Cartridge / Column
- Sample Volume: 1 to 2 cc
-
Supplier: Orochem Technologies, Inc.
Description: . Sep-Pak®cartridges may be substituted with Oro-Sep cartridges. Oro-Sep cartridges packed with reversed phases, normal phases, and ion exchange phases in three different bed sizes, may be utilized for sample preparation and sample concentration in the bio-tech, clinical,
- Configuration: Cartridge / Column
- Sample Volume: 1 to 60 cc
- Separation Mechanism: Syringe
-
Supplier: Applied Separations, Inc.
Description: Choose Spe-ed SPE products for the highest quality cartridges and the greatest selection available. Many of our standard silica-based sorbents are packed and available off the shelf for shipping the next business day in the following configurations. For additional packings, frits/filters, cartridge
- Configuration: Cartridge / Column
- Sample Volume: 1 to 60 cc
- Separation Mechanism: Syringe
- Sorbent Mass: 0.1000 to 20 g
-
-
Supplier: Bonna-Agela Technologies Inc.
Description: Solid phase extraction (SPE) is one of the most used techniques in sample preparation. It is replacing the conventional time-consuming liquid-liquid extraction (LLE) method. The process of SPE is a miniature version of liquid column chromatography. SPE, utilizing the same
- Configuration: Cartridge / Column
- Sample Volume: 1 to 2 cc
- Separation Mechanism: Syringe
- Sorbent Mass: 0.0100 to 0.1000 g
-
Supplier: Sepax Technologies, Inc.
Description: used as the reversed phase sorbent. The controlled manufacturing process guarantees high batch-to-batch reproducibility. Their high surface area and high mechanical strength enable those media ideal for extraction of acids, neutrals, bases and pharmaceuticals.
- Configuration: Cartridge / Column
- Particle Size: 60 µm
- Pore Size: 300 Å
- Sample Volume: 1 to 6 cc
-
Supplier: Sepax Technologies, Inc.
Description: . The controlled manufacturing process guarantees high batch-to-batch reproducibility. With high analyte capacity and high mechanical strength, Generik DBX is ideal for extraction of acidic, neutral and basic compounds.
- Configuration: Cartridge / Column
- Particle Size: 60 µm
- Sample Volume: 1 to 6 cc
- Sorbent Mass: 0.0300 to 0.5000 g
-
Supplier: Sepax Technologies, Inc.
Description: guarantees high batch-to-batch reproducibility. With high analyte capacity and high mechanical strength, Generik H2P is ideal for extraction of acidic, neutral and basic compounds. In the practical applications, Generik H2P is used as an alternative to Waters Oasis HLB.
- Configuration: Cartridge / Column
- Extraction Mechanism: Polar (Normally Bonded), Non-Polar (Reverse Phase)
- Particle Size: 40 µm
- Sample Volume: 1 to 6 cc
-
Supplier: Aurora Instruments
Description: Isolating compounds from biological and combinatorial chemistry matrices is a complex process. Standard manual methods are time consuming, prone to manual pipetting errors, and expensive reagents are often wasted unnecessarily. The primary purpose of solid phase extraction
-
Supplier: Western Analytical Products
Description: "1-10 µl Samples, Pipette mounted tip (Embedded tip)"
-
Supplier: Western Analytical Products
Description: "1-10 µl Samples, Pipette mounted tip (Packed Tip)"
-
Supplier: Western Analytical Products
Description: "10-200 µl Samples, Pipette Mounted Tip (Packed Tip)"
-
Supplier: Western Analytical Products
Description: "0.5-10 ml Samples, Syringe Mounted"
-
Supplier: Restek
Description: Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic solvents (e.g., polar contaminants from sample extracts).
- Configuration: Cartridge / Column
- Extraction Mechanism: Polar (Normally Bonded)
- Frit Material: Other
- Sample Volume: 3 to 15 cc
-
Supplier: Restek
Description: Hydrophobic (nonpolar) silica-based adsorbents, used to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water).
- Configuration: Cartridge / Column
- Extraction Mechanism: Non-Polar (Reverse Phase)
- Frit Material: Polyethylene
- Sample Volume: 1 to 60 cc
-
Supplier: Miles Scientific (Analtech)
Description: concept of solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain a
- Separation Mechanism: Vacuum Manifold
-
Supplier: Miles Scientific (Analtech)
Description: The concept of solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain
- Separation Mechanism: Vacuum Manifold
-
Solid Phase Extraction Cartridges and Disks - Extraction Columns - Type C18, 4mL (150/case) -- 11-52Supplier: Miles Scientific (Analtech)
Description: The concept of solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain
- Separation Mechanism: Vacuum Manifold
-
Supplier: Miles Scientific (Analtech)
Description: The concept of solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain
- Separation Mechanism: Vacuum Manifold
-
Supplier: Accuris
Description: Standard Test Method for 99Tc in Water by Solid Phase Extraction Disk
-
Description: Water quality -- Determination of selected nitrophenols -- Method by solid-phase extraction and gas chromatography with mass spectrometric detection
-
Description: Water quality -- Determination of selected phenoxyalkanoic herbicides, including bentazones and hydroxybenzonitriles by gas chromatography and mass spectrometry after solid phase extraction and derivatization
-
Supplier: Accuris
Description: Animal feeding stuffs - Determination of inorganic arsenic by hydride generation atomic absorption spectrometry (HG-AAS) after microwave extraction and separation by solid phase extraction (SPE)
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR 99TC IN WATER BY SOLID PHASE EXTRACTION DISK - INCLUDES STANDARD + REDLINE (PDF)
-
Supplier: Accuris
Description: STANDARD METHOD FOR DETERMINATION OF IPBC/PER IN SOLUTION AND WOOD USING HPLC AND SOLID-PHASE EXTRACTION
-
Supplier: SAE International
Description: laboratory has created an analytical technique that couples a selective sorption process based on solid phase extraction (SPE) with the quantitative measurement of the extract by a hand-held diffuse reflection spectrophotometer. This technique, referred to as
-
Supplier: SAE International
Description: We are developing a drinking water test kit based on colorimetric-solid phase extraction (C-SPE) for use onboard the International Space Station (ISS) and on future Lunar and/or Mars missions. C-SPE involves measuring the change in diffuse reflectance of indicator disks
-
Supplier: Teknokroma Analitica S.A.
Description: Teknokroma introduces in the market the new line of Finisterre™ Solid Phase Extraction columns for a fast and efficient sample clean-up and concentration prior to analysis through GC, HPLC, and/or other instrumental methods. SPE method concentrates and purifi es analytes from
- Configuration: Cartridge / Column
- Particle Size: 50 µm
- Sample Volume: 1 to 12 cc
- Sorbent Mass: 0.1000 to 1 g
-
Supplier: Restek
Description: High adsorbent capacity (surface area =200 m2/g) for large volume sampling. Chromatographic grade graphitized carbon provides consistent and quantitative recoveries of a wide variety of semivolatiles, pesticides, and herbicides. 500 mg bed weight
- Configuration: Cartridge / Column
- Extraction Mechanism: Non-Polar (Reverse Phase)
- Sorbent Mass: 0.5000 g
-
Description: ISO 24293:2009 specifies a method for the determination of selected individual isomers of nonylphenol in non-filtered samples of drinking water, waste water, ground water and surface water. The method is applicable in concentrations between 0,001 µg/l and 0,1 µg/l for individual isomers and from
-
Description: ISO 25101:2009 specifies a method for the determination of the linear isomers of perfluorooctanesulfo nate (PFOS) and perfluorooctanoate (PFOA) in unfiltered samples of drinking water, ground water and surface water (fresh water and sea water) using high-performance liquid chromatography-tande m
-
Supplier: ASTM International
Description: 1.1 This test method describes a solid phase extraction (SPE) procedure to separate 99Tc from environmental water samples (that is, non-process and effluent waters). Technetium-99 beta activity is measured by liquid scintillation spectrometry. 1.2 This test method is designed
-
Supplier: ASTM International
Description: 1.1 This test method describes a solid phase extraction (SPE) procedure to separate 99Tc from environmental water (non-process-related or effluent water samples). Technetium-99 beta activity is measured by liquid scintillation spectrometry. 1.2 This test method is
-
Supplier: ASTM International
Description: 1.1 This test method describes a solid phase extraction (SPE) procedure to separate 99Tc from environmental water samples (that is, non-process and effluent waters). Technetium-99 beta activity is measured by liquid scintillation spectrometry. 1.2 This test method is
-
Supplier: ASTM International
Description: 1.1 This test method describes a solid phase extraction (SPE) procedure to separate?99Tc from environmental water (non-process-related or effluent water samples). Technetium-99 beta activity is measured by liquid scintillation spectrometry. 1.2 This test method is
-
Supplier: SiliCycle Inc.
Description: SiliaPrepX DVB is a polystyrene-divinylb enzene copolymer presenting a high hydrophobicity used as reversed-phase for extraction of neutral, acidic and basic compounds in viscous matrices. Typical Applications Drugs & metabolites in biological fluids
- Configuration: Cartridge / Column
- Particle Size: 85 µm
- Pore Size: 60 Å
- Sample Volume: 1 to 70 cc
-
Supplier: Waters Corporation
Description: The Original and Most Referenced Silica-Based SPE ProductsA diverse selection of formats and silica-based sorbents provide the ideal sample extraction solution for GC, HPLC, and UPLC analysis methods. Available formats: Cartridges 96-well plates µElution plates
- Configuration: Cartridge / Column
-
Supplier: Thermo Fisher Scientific, Inc.
Description: For fast and easy solid-phase extraction (SPE) of nitrosamines (U.S. EPA Method 521) and 1,4-dioxane (U.S. EPA Method 522) in drinking water, use the Thermo Scientific™ Dionex™ SolEx™ Carbon-Based SPE Cartridges. This cartridge is available in 6mL format with 2g of packing. For
- Configuration: Cartridge / Column
- Sample Volume: 6 cc
- Separation Mechanism: Syringe
- Sorbent Mass: 0.5000 to 2 g
-
Supplier: Spark Holland BV
Description: The online SPE cartridge for Symbiosis™/ Prospekt-2 / ACE systems has been specially designed for online elution to the HPLC column. Dimensions are optimized to combine high extraction capacity with small elution volumes. Standard dimensions are 10 mm in length and 2 mm inner diameter, but
- Configuration: Cartridge / Column
- Disc Diameter: 2 mm
-
Supplier: SiliCycle Inc.
Description: 10 SiliaPrep (3 mL/200 mg) silica-based cartridges of each phase: SAX, SAX-2, WAX & 10 SiliaPrepX (3 mL/60 mg) polymeric cartridges of each phase: SAX, WAX Support Backbone Silica Gels, Polymeric Resins Array Amine (WAX), TMA Acetate (SAX
- Configuration: Cartridge / Column
- Extraction Mechanism: Ion-Exchange (Cation, Anion, Covalent)
- Sample Volume: 3 cc
- Separation Mechanism: Syringe
-
Supplier: SiliCycle Inc.
Description: 10 SiliaPrep (3 mL/200 mg) silica-based cartridges of each phase: SCX, SCX-2, WCX & 10 SiliaPrepX (3 mL/60 mg) polymeric cartridges of each phase: SCX, WCX Support Backbone Silica Gels, Polymeric Resins Array Carboxylic Acid (WCX
- Configuration: Cartridge / Column
- Extraction Mechanism: Ion-Exchange (Cation, Anion, Covalent)
- Sample Volume: 3 cc
- Separation Mechanism: Syringe
-
Supplier: Thermo Fisher Scientific, Inc.
Description: analyses. The Dionex™ SolEx™ C18-525 SPE Cartridge is for extraction of semivolatiles in drinking water for their lower method detection using U.S. EPA Method 525.2. These cartridges are designed for use with the Thermo Scientific™ Dionex™ AutoTrace™ 280 SPE system or other SPE
- Configuration: Cartridge / Column
- Sample Volume: 3 to 6 cc
- Separation Mechanism: Syringe
-
Supplier: Thermo Fisher Scientific, Inc.
Description: analyses. The Dionex™ SolEx™ C18-525 SPE Cartridge is for extraction of semivolatiles in drinking water for their lower method detection using U.S. EPA Method 525.2. These cartridges are designed for use with the Thermo Scientific™ Dionex™ AutoTrace™ 280 SPE system or other SPE
- Configuration: Cartridge / Column
- Sample Volume: 1 to 6 cc
- Separation Mechanism: Syringe
- Sorbent Mass: 0.1000 to 1.5 g
Find Suppliers by Category Top
Featured Products Top
-
systems use the EPA 533 PFAS testing method. This method specifically uses solid phase extraction (SPE) liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure various analytes in drinking water. Analytes Measured and Reporting Limits This particular method (read more)
Browse Analytical Laboratory Services Datasheets for DOD Technologies Inc. -
Analysis To accurately measure the levels of PFAS in drinking water, many systems use the EPA 533 PFAS testing method. This method specifically uses solid phase extraction (SPE) liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure various analytes in drinking water (read more)
Browse Water Quality Testing Instruments Datasheets for DOD Technologies Inc.
Conduct Research Top
-
Solid phase extraction of THC, THC-COOH and 11-OH-THC from whole blood
Application Note: Solid phase extraction of THC, THC-COOH and 11-OH-THC from whole blood.
-
Comprehensive Analysis of Persistent Organic Pollutants in Complex Matrices Using GC with High-Performance TOF-MS
interferences as well as variation. among technicians. Here we demonstrate a procedure that incorporates. a QuEChERS extraction, cartridge solid-phase extraction. (cSPE) cleanup and gas chromatography-time-of-flight mass spectrometry. (GC-TOFMS), resulting in good recoveries for a wide range
-
Copper Crud Treatment, concentration dependent pond depth adjustment for decanter centrifuges, DControl (R)
and undissolved solids, such as sand,. transported in the PLS cause problems in conjunction with incorrect agitator design. The. crud fraction can decisively impact the efficiency of the hydrometal extraction because. the phase interface can constitute a large fraction and the sedimentation tanks
More Information Top
-
Molecular imprinting science and technology: a survey of the literature for the years 2004–2011
Molecularly imprinted poly- mers for solid phase extraction .
-
http://www.sigmaaldrich.com/content/dam/sigma-aldrich/docs/Supelco/General_Information/1/t409146.pdf
Empore Extraction Disk Cartridges Method Summary, Solid Phase Extraction of Amiodarone and Desethylamiodarone from Serum .
-
Handbook of Green Analytical Chemistry
Molecularly imprinted solid phase extraction (MISPE).
-
Pesticide Protocols
1991) Solid phase extraction method for rapid isolation and clean-up of some synthetic pyrethroid insecticides from human urine and plasma.
-
Practical Gas Chromatography
The frontal technique is used for adsorptive enrichment of trace compounds from liquid samples ( Solid Phase Extraction SPE) or gases as well as cleanup of solvents from polar compounds.
-
Steroid Analysis
2003) Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges.
-
Postmortem Toxicology of Abused Drugs
Fortunately, many important achievements have been made in methodology, and the application of novel techniques, such as modifications of solid phase extraction and LC/MS techniques, now offers better conditions for efficient and sensitive analyses of numerous substances.
-
Drug Abuse Handbook
Solid phase extraction of .
-
Nanometer-sized materials for solid-phase extraction of trace elements
The keywords for searching were “ solid phase extraction ”, the specific nanostructured materials and “metal ions”/“element”/ “speciation”) .
-
Natural Products
2004) Solid phase extraction and LCMS analysis of pyrrolizidine alkaloids in honeys.
Indicates content that may require registration and/or purchase.