Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Bonna-Agela Technologies Inc.
Description: Solid phase extraction (SPE) is one of the most used techniques in sample preparation. It is replacing the conventional time-consuming liquid-liquid extraction (LLE) method. The process of SPE is a miniature version of liquid column chromatography. SPE, utilizing the same
- Sorbent Mass: 0.01 to 0.1 g
- Sample Volume: 1 to 2 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Syringe
-
Supplier: Orochem Technologies, Inc.
Description: Sep-Pak®cartridges may be substituted with Oro-Sep cartridges. Oro-Sep cartridges packed with reversed phases, normal phases, and ion exchange phases in three different bed sizes, may be utilized for sample preparation and sample concentration in the bio-tech, clinical,
- Sample Volume: 1 to 60.00000000000001 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Syringe
-
Supplier: Agilent Energy & Chemicals - Polymers
Description: We offer a wide range of solid phase extraction (SPE) products in various polarities and chemistries. A broad selection of Bond Elut sorbents is available in cartridge and well plate formats and as bulk sorbents. Frits, adapter caps, empty cartridges for custom packing, and
- Sample Volume: 1 to 2 cc
- Configuration: Cartridge / Column
-
-
Supplier: Applied Separations, Inc.
Description: Choose Spe-ed SPE products for the highest quality cartridges and the greatest selection available. Many of our standard silica-based sorbents are packed and available off the shelf for shipping the next business day in the following configurations. For additional packings, frits/filters, cartridge
- Sorbent Mass: 0.1 to 20 g
- Sample Volume: 1 to 60.00000000000001 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Syringe
-
Supplier: Sepax Technologies, Inc.
Description: reversed phase sorbent. The controlled manufacturing process guarantees high batch-to-batch reproducibility. Their high surface area and high mechanical strength enable those media ideal for extraction of acids, neutrals, bases and pharmaceuticals.
- Sorbent Mass: 0.03 to 0.5 g
- Sample Volume: 1 to 6 cc
- Particle Size: 60 µm
- Pore Size: 300 Å
-
Supplier: Aurora Instruments
Description: efficiency by minimizing sample preparation time and reducing the cumbersome nature of solid phase extraction, thereby producing cost effective solutions while increasing the throughput and reproducibility of the process. The VERSATM solid phase extraction
-
Supplier: Western Analytical Products
Description: "0.5-10 ml Samples, Syringe Mounted"
-
Supplier: Accuris
Description: Standard Test Method for 99Tc in Water by Solid Phase Extraction Disk
-
Supplier: ASTM International
Description: 1.1 This test method describes a solid phase extraction (SPE) procedure to separate 99Tc from environmental water (non-process-related or effluent water samples). Technetium-99 beta activity is measured by liquid scintillation spectrometry. 1.2 This test method is designed to
-
Supplier: Accuris
Description: STANDARD METHOD FOR DETERMINATION OF IPBC/PER IN SOLUTION AND WOOD USING HPLC AND SOLID-PHASE EXTRACTION
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR 99TC IN WATER BY SOLID PHASE EXTRACTION DISK - INCLUDES STANDARD + REDLINE (PDF)
-
Description: Water quality -- Determination of selected nitrophenols -- Method by solid-phase extraction and gas chromatography with mass spectrometric detection
-
Supplier: Accuris
Description: Water quality - Determination of selected nitrophenols - Method by solid-phase extraction and gas chromatography with mass spectrometric detection
-
Description: Water quality -- Determination of selected phenoxyalkanoic herbicides, including bentazones and hydroxybenzonitriles by gas chromatography and mass spectrometry after solid phase extraction and derivatization
-
Supplier: SAE International
Description: laboratory has created an analytical technique that couples a selective sorption process based on solid phase extraction (SPE) with the quantitative measurement of the extract by a hand-held diffuse reflection spectrophotometer. This technique, referred to as
-
Supplier: SAE International
Description: We are developing a drinking water test kit based on colorimetric-solid phase extraction (C-SPE) for use onboard the International Space Station (ISS) and on future Lunar and/or Mars missions. C-SPE involves measuring the change in diffuse reflectance of indicator disks
-
Supplier: CSA Group
Description: ISO 20179:2005 specifies a method for the determination and quantification of microcystins in raw water (containing biomass) and treated water, such as tap water. The method described is validated for MCYST-RR, MCYST-YR, and MCYST-LR. It is also applicable for the determination of several structure
-
Supplier: CSA Group
Description: ISO 24293:2009 specifies a method for the determination of selected individual isomers of nonylphenol in non-filtered samples of drinking water, waste water, ground water and surface water. The method is applicable in concentrations between 0,001 µg/l and 0,1 µg/l for individual isomers and from
-
Description: ISO 24293:2009 specifies a method for the determination of selected individual isomers of nonylphenol in non-filtered samples of drinking water, waste water, ground water and surface water. The method is applicable in concentrations between 0,001 µg/l and 0,1 µg/l for individual isomers and from
-
Description: ISO 20179:2005 specifies a method for the determination and quantification of microcystins in raw water (containing biomass) and treated water, such as tap water. The method described is validated for MCYST-RR, MCYST-YR, and MCYST-LR. It is also applicable for the determination of several structure
-
Supplier: CSA Group
Description: ISO 25101:2009 specifies a method for the determination of the linear isomers of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) in unfiltered samples of drinking water, ground water and surface water (fresh water and sea water) using high-performance liquid chromatography-tandem mass
-
Supplier: ASTM International
Description: 1.1 This test method covers the separation and determination of representative aromatics, nonaromatics, and fatty acid methyl ester (FAME) fractions in middle distillates that boil between 170 °C and 400 °C, including biodiesel blends with up to 20 % by volume of FAME, by solid phase
-
Supplier: Miles Scientific (Analtech)
Description: of solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain water and a
- Separation Mechanism: Vacuum Manifold
-
Supplier: Miles Scientific (Analtech)
Description: solid phase extraction has been applied to a broad range of materials including drugs of abuse, drug metabolites and steroids, and environmental pollutants. Extraction columns are supplied with a cap, waste cup, and sample recovery cup. The columns contain a nominal 120mg
- Separation Mechanism: Vacuum Manifold
-
Supplier: Restek
Description: Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic solvents (e.g., polar contaminants from sample extracts).
- Sorbent Mass: 0.5 to 2 g
- Sample Volume: 3 to 15.000000000000002 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Centrifugation, Syringe, Vacuum Manifold
-
Supplier: Miles Scientific (Analtech)
Description: Porous polyethylene disc for use in SPICE Tubes. Used to retain adsorbent in disposable Solid Phase Extraction applications. Diameter is 14.75 mm. Thickness is 1.7 mm. Porosity is 15 microns nominal. Package of 100 discs.
- Disc Diameter: 14.75 mm
- Configuration: Disc
- Frit Material: Polyethylene
-
Supplier: Teknokroma Analitica S.A.
Description: Teknokroma introduces in the market the new line of Finisterre™ Solid Phase Extraction columns for a fast and efficient sample clean-up and concentration prior to analysis through GC, HPLC, and/or other instrumental methods. SPE method concentrates and purifi es analytes from
- Sorbent Mass: 0.1 to 1 g
- Sample Volume: 1 to 12 cc
- Particle Size: 50 µm
- Configuration: Cartridge / Column
-
Supplier: KINTEP NEW POWER
Description: Introduction:High-efficiency commercial 3-phase separator for solids, water, and oil. Extracted waste oil can be recycled and processedGreasy wastewater causes pipe blockages, foul odors, and environmental pollution. Improper disposal of waste oil represents a lost resource and a
- Features: Other
-
Supplier: Thermo Fisher Scientific, Inc.
Description: For fast and easy solid-phase extraction (SPE) of nitrosamines (U.S. EPA Method 521) and 1,4-dioxane (U.S. EPA Method 522) in drinking water, use the Thermo Scientific™ Dionex™ SolEx™ Carbon-Based SPE Cartridges. This cartridge is available in 6mL format with 2g of packing. For
- Sorbent Mass: 0.5 to 2 g
- Sample Volume: 6 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Syringe
-
Supplier: SiliCycle Inc.
Description: SiliaPrepX DVB is a polystyrene-divinylbenzene copolymer presenting a high hydrophobicity used as reversed-phase for extraction of neutral, acidic and basic compounds in viscous matrices. Typical Applications Drugs & metabolites in biological fluids API from tablets, creams, in waste
- Sorbent Mass: 0.01 to 5 g
- Sample Volume: 1 to 70 cc
- Particle Size: 85 µm
- Pore Size: 60 Å
-
Supplier: Waters Corporation
Description: The Original and Most Referenced Silica-Based SPE ProductsA diverse selection of formats and silica-based sorbents provide the ideal sample extraction solution for GC, HPLC, and UPLC analysis methods. Available formats: Cartridges 96-well plates µElution plates
- Configuration: Cartridge / Column
-
Supplier: SiliCycle Inc.
Description: 10 SiliaPrep (3 mL/200 mg) silica-based cartridges of each phase: SAX, SAX-2, WAX & 10 SiliaPrepX (3 mL/60 mg) polymeric cartridges of each phase: SAX, WAX Support Backbone Silica Gels, Polymeric Resins Array Amine (WAX), TMA Acetate (SAX-2), TMA Chloride (SAX) Family / Formats
- Sorbent Mass: 0.06 to 0.2 g
- Sample Volume: 3 cc
- Configuration: Cartridge / Column
- Extraction Mechanism: Ion-Exchange (Cation, Anion, Covalent)
-
Supplier: Thermo Fisher Scientific, Inc.
Description: Concentrate strong anions such as sulfonates using the mixed-mode, reversed-phase, anion-exchange functionality of the Thermo Scientific™ Dionex™ SolEx™ WAX Polymer-Based SPE Cartridge. The WAX stationary phase is comprised of a medium-surface-area divinylbenzene resin particle grafted
- Sorbent Mass: 0.06 to 0.5 g
- Sample Volume: 3 to 6 cc
- Configuration: Cartridge / Column
- Separation Mechanism: Syringe
-
Supplier: Spark Holland BV
Description: The online SPE cartridge for Symbiosis™/ Prospekt-2 / ACE systems has been specially designed for online elution to the HPLC column. Dimensions are optimized to combine high extraction capacity with small elution volumes. Standard dimensions are 10 mm in length and 2 mm inner diameter, but 10
- Disc Diameter: 2 mm
- Configuration: Cartridge / Column
-
Supplier: Restek
Description: cartridges in four dimensions, with a variety of bonded phases to match your analytical column. The economical, leak-free cartridge design provides an unprecedented combination of convenience, economy, and reliability.
- Configuration: Cartridge / Column
Find Suppliers by Category Top
Featured Products Top
-
Analysis To accurately measure the levels of PFAS in drinking water, many systems use the EPA 533 PFAS testing method. This method specifically uses solid phase extraction (SPE) liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure various analytes in drinking water (read more)
Browse Water Quality Testing Instruments Datasheets for DOD Technologies Inc. -
systems use the EPA 533 PFAS testing method. This method specifically uses solid phase extraction (SPE) liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure various analytes in drinking water. Analytes Measured and Reporting Limits This particular method can (read more)
Browse Analytical Laboratory Services Datasheets for DOD Technologies Inc.
Conduct Research Top
-
Solid phase extraction of THC, THC-COOH and 11-OH-THC from whole blood
Application Note: Solid phase extraction of THC, THC-COOH and 11-OH-THC from whole blood.
-
Comprehensive Analysis of Persistent Organic Pollutants in Complex Matrices Using GC with High-Performance TOF-MS
interferences as well as variation. among technicians. Here we demonstrate a procedure that incorporates. a QuEChERS extraction, cartridge solid-phase extraction. (cSPE) cleanup and gas chromatography-time-of-flight mass spectrometry. (GC-TOFMS), resulting in good recoveries for a wide range
-
Copper Crud Treatment, concentration dependent pond depth adjustment for decanter centrifuges, DControl (R)
and undissolved solids, such as sand,. transported in the PLS cause problems in conjunction with incorrect agitator design. The. crud fraction can decisively impact the efficiency of the hydrometal extraction because. the phase interface can constitute a large fraction and the sedimentation tanks
More Information Top
-
Molecular imprinting science and technology: a survey of the literature for the years 2004–2011
Molecularly imprinted poly- mers for solid phase extraction .
-
http://www.sigmaaldrich.com/content/dam/sigma-aldrich/docs/Supelco/General_Information/1/t409146.pdf
Empore Extraction Disk Cartridges Method Summary, Solid Phase Extraction of Amiodarone and Desethylamiodarone from Serum .
-
Handbook of Green Analytical Chemistry
Molecularly imprinted solid phase extraction (MISPE).
-
Pesticide Protocols
1991) Solid phase extraction method for rapid isolation and clean-up of some synthetic pyrethroid insecticides from human urine and plasma.
-
Practical Gas Chromatography
The frontal technique is used for adsorptive enrichment of trace compounds from liquid samples ( Solid Phase Extraction SPE) or gases as well as cleanup of solvents from polar compounds.
-
Steroid Analysis
2003) Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges.
-
Postmortem Toxicology of Abused Drugs
Fortunately, many important achievements have been made in methodology, and the application of novel techniques, such as modifications of solid phase extraction and LC/MS techniques, now offers better conditions for efficient and sensitive analyses of numerous substances.
-
Drug Abuse Handbook
Solid phase extraction of .
-
Nanometer-sized materials for solid-phase extraction of trace elements
The keywords for searching were “ solid phase extraction ”, the specific nanostructured materials and “metal ions”/“element”/ “speciation”) .
-
Natural Products
2004) Solid phase extraction and LCMS analysis of pyrrolizidine alkaloids in honeys.
Indicates content that may require registration and/or purchase.