Products/Services for Steam Turbine Ventilator Valve
-
Steam Valves - (239 companies)It is used for powering turbines to generate electricity and for food, chemical and other product processing. Steam is also used for cleaning, heating, and humidification. Most applications require some control, and steam control valves become...Metal SeatedValve TypeConnection -
Steam and Gas Turbines - (78 companies)Steam turbines and gas turbines are rotating machines that extract energy from pressurized steam and/or from combustion gases. Types of Steam and Gas Turbines. There are two basic types of steam turbines: impulse and reaction. Impulse turbines... -
Steam Traps - (227 companies)Steam traps are automatic valves that release condensate from a steam space while preventing the loss of live steam. They also remove air and noncondensables from the steam space. Steam traps are automatic valves that release condensate from a steam... -
Roof Vents and Ventilators - (69 companies)Passive ventilators rely on the chimney effect and often have an air powered turbine, driven by the rising hot air inside or wind flow outside. Powered ventilators have an electric fan inside and can move more air for a given pipe diameter, at the cost...
-
Turbine Repair and Maintenance Services - (113 companies)Turbine repair and maintenance services provide maintenance, overhauls and repairs to wind, gas, steam and water turbines. Turbine repair and maintenance services provide maintenance, overhauls, and repairs to wind, gas, steam, and water turbines...
-
Medical Ventilators - (25 companies)Medical ventilators are machines that mechanically move air/oxygen into the lungs of a patient who is experiencing respiratory complications. Medical ventilators are mechanical apparatuses that forcibly respire a patient whose lung function...
-
Wind Turbines - (269 companies)Wind turbines convert the kinetic energy from wind into mechanical energy. When used with an electrical generator, the rotation of the wind turbine 's blades turns a shaft to produce electricity. Wind turbines convert the kinetic energy from wind...
-
Steam Injection Heaters - (26 companies)...for securing the heater. On a much larger scale, a heat recovery steam generator is a type of boiler used in power plants to take advantage of the waste heat generated by a gas-powered turbine. The waste heat from the gas turbine is used to heat water...
-
Turbine Pumps - (249 companies)Turbine pumps are centrifugal pumps that use pressure in combination with a rotary mechanism to transfer fluid. They typically employ blade geometry, which causes fluid circulation around the vanes to add pressure from inlet to outlet. Turbine pumps...
-
Hydro Turbines - (56 companies)Hydro turbines are used to transmit mechanical power and produce electricity. Hydro turbines convert water pressure into mechanical shaft power that can be used to drive an electricity generator, grind a mill, or move some other device. Hydro...
Product News
-
IMI Life Science
High Back-Pressure Valve for Ventilators Technical Specifications. 16mm FLATPROP EQC MAX. High?flow valve engineered to maintain exceptional performance under high downstream back?pressure. EQCMAX is the ideal solution for architectures where restrictions or long downstream circuits create significant counter?pressure. Pressure?compensated proportional valve. Exceptional back?pressure capability: up to 90% of inlet pressure. High flow: 160 l/min at 2 barg. Robust, frictionless design for long?life, repeatable control. Suitable... (read more)Browse Industrial Valves Datasheets for IMI Life Science -
Kaydon Filtration Corporation
Steam Turbine Oil Conditioning & Water Removal High-Efficiency Oil Conditioning for Reliable Turbine Performance. The most efficient conditioning system in the market for water removal, TURBO-TOC (R) removes 100% of damaging water from turbine oil and reduces Total Water Content to 100 ppm (0 ppm free, 0 ppm emulsified, 100 ppm dissolved). Engineered for high-efficiency fluid conditioning. TURBO-TOC (R) systems deliver 99% removal of free and emulsified water in a single pass, reducing total water content to below 100 ppm. Designed... (read more)Browse Filtration Equipment Datasheets for Kaydon Filtration Corporation -
Portescap
BLDC Motors Optimize Ventilator Performance Ventilators. The compressed air or oxygen is usually fed through hospital supply lines or via a tank that is directly fed by a compressor. The air is then supplied to the patient with the help of bellows, vents, or regulation valves. Another type of compressor- based ventilator uses pistons to compress air that is generally actuated by electric motors. In this case, there is no need for compressed air or oxygen drawn from hospital supply lines or a compressor. Turbine-Driven Ventilators. Similar... (read more)Browse DC Motors Datasheets for Portescap -
Shanghai Thinktank Process Management Co., Ltd
High-Temperature Safety Valves for Steam High-Temperature Safety Valves for Industrial Pressure Protection. Industrial steam systems and high-pressure pipelines require reliable safety valves capable of operating under extreme temperature and pressure conditions. Proper pressure relief is critical for protecting equipment and ensuring safe operation in power generation and industrial processing systems. The THINKTANK high-temperature safety valve is engineered to deliver dependable overpressure protection in demanding environments... (read more)Browse Industrial Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
DFT Inc.
Reliable Steam Service Check Valves from DFT® DFT has a full line of Steam Service Check Valves available in sizes 1/2" and up for your steam applications. Over the years, many different industries have asked DFT (R) which of our check valves are the best for steam service applications on their 4 " and under piping. Below is a collection of non-slam, tight shut-off check valves that fit these criteria: DFT Model Basic Check (R) * DFT Model Restrictor Check. DFT Model SCV (R) * DFT Model SCV-R (R). DFT Model Vacuum Breaker. For your... (read more)Browse Steam Valves Datasheets for DFT Inc. -
GEEPLUS Inc.
Medical & Ventilator Voice Coil Actuators Because of the precision, control and reliability required in life-sustaining medical equipment, Geeplus has found a niche as the worldwide leading supplier of actuators in ventilator applications. Our customized voice coil actuators are found in a healthy percentage of high end medical ventilators today because, well, they are frankly the best in the world -or so we 're told by the engineers that design the most advanced ventilator machines on the market today. Essential Benefits... (read more)Browse Voice Coil Actuators and Motors Datasheets for GEEPLUS Inc. -
Shanghai Thinktank Process Management Co., Ltd
High-Temp Safety Valve for Steam, 0.2 MPa Rated Product Overview. The TTA42C-150LB-C-050 is an industrial-grade safety valve engineered for high-reliability pressure relief in thermal and mechanical systems. Designed for applications in steam, gas, and multiphase process environments, this valve offers stable performance under elevated temperatures and variable pressure conditions. Its compact construction and robust cast steel body make it ideal for equipment protection in power plants, process automation, and energy infrastructure... (read more)Browse Pressure Relief Valves Datasheets for Shanghai Thinktank Process Management Co., Ltd -
RS Components, Ltd.
MAXIM Ventilator solutions page In response to COVID-19, we have worked with our partners Maxim Integrated to provide simple design resources to support the design of complex ventilators. Learn why temperature sensors, power amplifiers, and digital-to-analog converters all perform vital roles in the operation of these life-saving devices. Find the key components and block diagrams to start building your own prototype. (read more)Browse Power Amplifiers Datasheets for RS Components, Ltd. -
Constar Motion Co., Ltd
24V BLDC Blower for Ventilators In medical devices, high noise, inconsistent airflow, and unreliable long-term performance can compromise patient comfort and device effectiveness, particularly in CPAP and ventilator systems. Designed for efficiency, quiet operation, and durability, this blower delivers: Ultra-quiet operation with <=40?dB noise level, ensuring a peaceful environment for patients. Consistent airflow of 3.6?m ^3/h, providing adequate ventilation without overloading the system. Durable brushless DC motor for long... (read more)Browse Fans and Blowers (industrial) Datasheets for Constar Motion Co., Ltd -
Hartzell Air Movement
Direct Upblast Roof Ventilator Series 61. The Series 61 Direct Drive Upblast Roof Ventilator meets the need for an economical, yet efficient upblast roof ventilator. The unit combines the Hartzell panel fan concept with a windband and butterfly damper. Dampers open automatically when the fan goes on and close weathertight when the fan is shut down. When the unit is in operation, the force of the discharge air effectively prevents the entry of rain or snow. "H " (heavy industrial) duty construction features motor supports... (read more)Browse Fans and Blowers (industrial) Datasheets for Hartzell Air Movement
-
Nuclear Computerized Library for Assessing Reactor Reliability (NUCLARR)
ACCUMULATORS AIR/GAS DRYERS BATTERIES BATTERY CHARGERS CIRCUIT CLOSURES/INTERRUPTERS COMPUTERS CONTROL INSTRUMENTS CONTROL ROD DRIVE MECHANISMS CONTROL RODS DEMINERALIZERS EDUCTORS ELECTRICGENERATORS ELECTRICHEATERS ELECTRICALCONDUCTORS ELECTRICALEQUIPMENT EQUIPMENT- NONSPECIFIC FANS/ VENTILATORS FILTERS/STRAINERS HEAT EXCHANGERS MOTORS PIPES PUMPS RECOMBINERS SENSORS STEAM GENERATORS TURBINES VALVE OPERILTORS VALVES VESSELS/TANKS .
-
Load Rejection Capability for Large Steam Generators
During operation on the steam to reheater bypass system, the HP turbine is blocked and a ventilator line and valve to the condenser are furnished upstream of the check valve at the HP turbine exhaust.
-
Experimental House Load Operation At Tanagawa No.2 Oil-Fired Power Station
At a time of main turbine trip, a large amount of RH steam is dumped into the condenser through primary and secondary ventilator valve in oirder to avoid main turbine speeding (See Figure 8).
Indicates content that may require registration and/or purchase.