Description: This thermostat operates as a thermal cutout. A thermally sensitive bimetal snap-element with single contacts either opens or closes an electrical circuit by switching at a pre-set response temperature. Reset follows automatically after a considerable drop in temperature. Applications
- High Temperature Set Point: 149 to 356 F
- Repeatability / Tolerance: 9 to 27 F
- Maximum Current: 0.001 to 22 amps
- Maximum AC Voltage: 120 to 600 volts
-
Description: Strip, Coil, Foil & Wire, ASTM F-30 APPLICATIONS Semiconductor lead frames, thermostat bi-metal strips, metal to glass sealing applications in microelectronic components DESCRIPTION Alloy 42 is a nickel-iron alloy that has a low, and normally constant, coefficient of thermal expansion
- UNS Number: 94,100
- Tensile Strength (UTS, Break): 71,000 psi
- Yield Strength (YS): 36,000 psi
- Elongation: 43 %
-
Supplier: Tempco Electric Heater Corporation
Description: Typical Applications Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional Grounded internal metal element for
- Maximum Operating (Sheath) Temperature: 190 F
- AC Voltage Required: 120 to 480 volts
- kWatts: 0.5 to 6 kW
- Watt Density: 10 W/in²
-
-
Supplier: Tempco Electric Heater Corporation
Description: Typical Applications Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190°F (88°C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional Grounded internal metal element for
- Maximum Operating (Sheath) Temperature: 190 F
- AC Voltage Required: 120 to 480 volts
- kWatts: 0.5 to 6 kW
- Watt Density: 10 W/in²
-
Supplier: OMEGA Engineering, Inc.
Description: activates a plunger, causing the heavy duty switch contacts to open. The CCD100N is normally used as an across-the-line switch, but may be used to operate contactor coils and other similar devices.
- High Temperature Set Point: 35 to 200 F
- Repeatability / Tolerance: 5 F
- Maximum Current: 25 amps
- Maximum AC Voltage: 277 volts
-
Supplier: Thermtrol
Description: load capacity High operating speed Current insensitive Moisture resistant Applications Hydronic fan coils Humidifier Dehumidifier HVAC Major appliances Medical/lab equipment Vending machines Electric space heaters Hair care appliances Audio speakers Copiers Refrigeration compressors
- High Temperature Set Point: 176 F
- Maximum Current: 5 to 10 amps
- Maximum AC Voltage: 12 to 240 volts
- Maximum Diameter or Width: 0.5 inch
-
Supplier: UL Standards & Engagement
Description: actuating element. 1 1.2 Replacement: This standard applies to door locks with electrical circuits and CONTROL circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements. 1 1.3
Find Suppliers by Category Top
Featured Products Top
-
. This is easy to do with PEPI devices and the result is a thermal protector providing overload protection without being mounted in the coils. PEPI versatility leads to greater reliability at an affordable price. (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for Portage Electric Products, Inc.
Conduct Research Top
-
Selection of Thermal Protector in Motor Product Application
burnout is mainly caused by the following reasons such as overheating of the locked-rotor coil, excessive load, motor overload, and lack of phase. Installing a thermal protector is one of the effective ways to protect the motor. Thermal protector, also called temperature switch, temperature control
More Information Top
-
Actuators: design fundamentals, key performance specifications, and parametric trades
The thermal force generated when the bimetal coil is clamped can be determined by .
-
Handbook of Modern Sensors
Fig. 4.38 Warping of laminated plate where two materials have different coefficients of thermal expansion (a); bimetal coil used as temperature transducer (b) .
-
Handbook of Modern Sensors
(A) Warping of a laminated plate where two materials have different coefficients of thermal expansion; (B) a bimetal coil used as a temperature transducer.
-
From Animals to Robots and Back: Reflections on Hard Problems in the Study of Cognition
To be more concrete, we will keep in mind a specific thermostat design where the thermometer component is a spiral bimetal coil , composed of two metals with differing coefficients of thermal expansion, which winds smaller or unwinds larger as the temperature changes.
-
CR4 - Thread: Electric Motor Starters
If you mean u/v coil as in thermal overloads on motor protection overload relays, which is made of bimetal strips, consisting of under voltage strip and over voltage strip...then these strips break or trip due to under voltages and over voltages …
-
THERMAL PROPERTIES AS USED FOR AUTOMATIC ANALYSIS
In the process industry the following methods are used chiefly for temperature measurements : Devices based on the thermal expansion of solids consist of structures composed of bimetal elements in the form of strips or coils .
-
IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems
1) Excessive friction or binding of the trip bar so that the bimetal cannot exert sufficient pressure to move the trip bar 2) Defective bimetal or dashpot assembly disabling … … 3) Open turn or thermal of a trip coil 4) Foreign matter preventing …
-
Handbook of Electrical Design Details, Second Edition > SERVICE ENTRANCE, LOADCENTERS, AND GROUNDING
Some thermal circuit breakers rated for 5 A or lower contain heater coils adjacent to or in series with the bimetal element.